Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,10 @@ 4 4 5 5 6 6 7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 7 7 9 + 10 + 8 8 **Table of Contents:** 9 9 10 10 {{toc/}} ... ... @@ -288,7 +288,7 @@ 288 288 ((( 289 289 **Description** 290 290 ))) 291 -)))|=(% style="width: 210px;" %)((( 294 +)))|=(% style="width: 2100px;" %)((( 292 292 ((( 293 293 **Example** 294 294 ))) ... ... @@ -392,17 +392,11 @@ 392 392 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 393 393 |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 394 394 |AT+CFGDEV|(% style="width:80px" %)((( 395 -((( 396 396 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 397 -))) 398 398 399 -((( 400 400 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 401 -))) 402 402 403 -((( 404 404 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 405 -))) 406 406 )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 407 407 408 408 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. ... ... @@ -873,7 +873,7 @@ 873 873 ))) 874 874 875 875 ((( 876 - **}**873 +} 877 877 878 878 879 879 ))) ... ... @@ -1426,16 +1426,34 @@ 1426 1426 ((( 1427 1427 ((( 1428 1428 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1426 +))) 1427 +))) 1429 1429 1429 +((( 1430 1430 Set UART Parity 1431 +))) 1432 + 1433 +(% class="box infomessage" %) 1434 +((( 1435 +((( 1431 1431 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1437 +))) 1438 +))) 1432 1432 1440 +((( 1433 1433 Set STOPBIT 1442 +))) 1434 1434 1444 +(% class="box infomessage" %) 1445 +((( 1446 +((( 1435 1435 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1436 1436 ))) 1437 1437 ))) 1438 1438 1451 +((( 1452 + 1453 +))) 1439 1439 1440 1440 * ((( 1441 1441 **Downlink Payload:** ... ... @@ -1592,12 +1592,18 @@ 1592 1592 1593 1593 == 3.10 Switch Jumper == 1594 1594 1595 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1596 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1597 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1610 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1611 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1612 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1613 +ISP position: Upgrade firmware via UART 1614 + 1598 1598 Flash position: Configure device, check running status. 1599 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1616 +))) 1617 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1618 +5V position: set to compatible with 5v I/O. 1619 + 1600 1600 3.3v position: set to compatible with 3.3v I/O., 1621 +))) 1601 1601 1602 1602 ((( 1603 1603 **+3.3V**: is always ON ... ... @@ -1645,7 +1645,15 @@ 1645 1645 (% class="box infomessage" %) 1646 1646 ((( 1647 1647 **AT+FDR** 1669 +))) 1670 + 1671 +(% class="box infomessage" %) 1672 +((( 1648 1648 **AT+NJM=0** 1674 +))) 1675 + 1676 +(% class="box infomessage" %) 1677 +((( 1649 1649 **ATZ** 1650 1650 ))) 1651 1651