Last modified by Xiaoling on 2025/04/23 15:57

From version 44.3
edited by Xiaoling
on 2022/06/14 09:44
Change comment: There is no comment for this version
To version 41.42
edited by Xiaoling
on 2022/06/06 11:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,7 +4,10 @@
4 4  
5 5  
6 6  
7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual**
7 7  
9 +
10 +
8 8  **Table of Contents:**
9 9  
10 10  {{toc/}}
... ... @@ -280,28 +280,28 @@
280 280  )))
281 281  
282 282  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
283 -|=(% style="width: 80px;" %)(((
286 +|=(% style="width: 120px;" %)(((
284 284  (((
285 285  **AT Commands**
286 286  )))
287 -)))|=(% style="width: 210px;" %)(((
290 +)))|=(% style="width: 190px;" %)(((
288 288  (((
289 289  **Description**
290 290  )))
291 -)))|=(% style="width: 210px;" %)(((
294 +)))|=(% style="width: 190px;" %)(((
292 292  (((
293 293  **Example**
294 294  )))
295 295  )))
296 -|(% style="width:80px" %)(((
299 +|(% style="width:120px" %)(((
297 297  (((
298 298  AT+BAUDR
299 299  )))
300 -)))|(% style="width:210px" %)(((
303 +)))|(% style="width:190px" %)(((
301 301  (((
302 302  Set the baud rate (for RS485 connection). Default Value is: 9600.
303 303  )))
304 -)))|(% style="width:210px" %)(((
307 +)))|(% style="width:190px" %)(((
305 305  (((
306 306  (((
307 307  AT+BAUDR=9600
... ... @@ -314,11 +314,11 @@
314 314  )))
315 315  )))
316 316  )))
317 -|(% style="width:80px" %)(((
320 +|(% style="width:120px" %)(((
318 318  (((
319 319  AT+PARITY
320 320  )))
321 -)))|(% style="width:210px" %)(((
324 +)))|(% style="width:190px" %)(((
322 322  (((
323 323  (((
324 324  Set UART parity (for RS485 connection)
... ... @@ -330,7 +330,7 @@
330 330  Default Value is: no parity.
331 331  )))
332 332  )))
333 -)))|(% style="width:210px" %)(((
336 +)))|(% style="width:190px" %)(((
334 334  (((
335 335  (((
336 336  AT+PARITY=0
... ... @@ -343,11 +343,11 @@
343 343  )))
344 344  )))
345 345  )))
346 -|(% style="width:80px" %)(((
349 +|(% style="width:120px" %)(((
347 347  (((
348 348  AT+STOPBIT
349 349  )))
350 -)))|(% style="width:210px" %)(((
353 +)))|(% style="width:190px" %)(((
351 351  (((
352 352  (((
353 353  Set serial stopbit (for RS485 connection)
... ... @@ -359,7 +359,7 @@
359 359  Default Value is: 1bit.
360 360  )))
361 361  )))
362 -)))|(% style="width:210px" %)(((
365 +)))|(% style="width:190px" %)(((
363 363  (((
364 364  (((
365 365  AT+STOPBIT=0 for 1bit
... ... @@ -379,6 +379,8 @@
379 379  )))
380 380  )))
381 381  
385 +
386 +
382 382  === 3.3.2 Configure sensors ===
383 383  
384 384  (((
... ... @@ -390,20 +390,14 @@
390 390  )))
391 391  
392 392  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
393 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
394 -|AT+CFGDEV|(% style="width:80px" %)(((
395 -(((
398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
399 +|AT+CFGDEV|(% style="width:120px" %)(((
396 396  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
397 -)))
398 398  
399 -(((
400 400  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
401 -)))
402 402  
403 -(((
404 404  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
405 -)))
406 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
407 407  
408 408  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
409 409  
... ... @@ -873,7 +873,7 @@
873 873  )))
874 874  
875 875  (((
876 -**}**
875 +{{{}}}}
877 877  
878 878  
879 879  )))
... ... @@ -903,6 +903,8 @@
903 903  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
904 904  )))
905 905  
905 +
906 +
906 906  === 3.5.1 Common Commands: ===
907 907  
908 908  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1426,16 +1426,34 @@
1426 1426  (((
1427 1427  (((
1428 1428  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1430 +)))
1431 +)))
1429 1429  
1433 +(((
1430 1430  Set UART Parity
1435 +)))
1436 +
1437 +(% class="box infomessage" %)
1438 +(((
1439 +(((
1431 1431  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1441 +)))
1442 +)))
1432 1432  
1444 +(((
1433 1433  Set STOPBIT
1446 +)))
1434 1434  
1448 +(% class="box infomessage" %)
1449 +(((
1450 +(((
1435 1435  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1436 1436  )))
1437 1437  )))
1438 1438  
1455 +(((
1456 +
1457 +)))
1439 1439  
1440 1440  * (((
1441 1441  **Downlink Payload:**
... ... @@ -1513,6 +1513,8 @@
1513 1513  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1514 1514  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1515 1515  
1535 +
1536 +
1516 1516  == 3.7 +3V3 Output ==
1517 1517  
1518 1518  (((
... ... @@ -1590,14 +1590,22 @@
1590 1590  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1591 1591  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1592 1592  
1614 +
1615 +
1593 1593  == 3.10 Switch Jumper ==
1594 1594  
1595 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %)
1596 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature**
1597 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART
1618 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
1619 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature**
1620 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)(((
1621 +ISP position: Upgrade firmware via UART
1622 +
1598 1598  Flash position: Configure device, check running status.
1599 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O.
1624 +)))
1625 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)(((
1626 +5V position: set to compatible with 5v I/O.
1627 +
1600 1600  3.3v position: set to compatible with 3.3v I/O.,
1629 +)))
1601 1601  
1602 1602  (((
1603 1603  **+3.3V**: is always ON
... ... @@ -1645,7 +1645,15 @@
1645 1645  (% class="box infomessage" %)
1646 1646  (((
1647 1647  **AT+FDR**
1677 +)))
1678 +
1679 +(% class="box infomessage" %)
1680 +(((
1648 1648  **AT+NJM=0**
1682 +)))
1683 +
1684 +(% class="box infomessage" %)
1685 +(((
1649 1649  **ATZ**
1650 1650  )))
1651 1651  
... ... @@ -1787,6 +1787,8 @@
1787 1787  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1788 1788  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1789 1789  
1827 +
1828 +
1790 1790  = 9. Packing Info =
1791 1791  
1792 1792  (((