Last modified by Xiaoling on 2025/04/23 15:57

From version 44.29
edited by Xiaoling
on 2022/06/14 10:31
Change comment: There is no comment for this version
To version 44.23
edited by Xiaoling
on 2022/06/14 10:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -952,6 +952,7 @@
952 952  **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
953 953  
954 954  
955 +
955 955  * (% style="color:#037691" %)**Downlink Payload**
956 956  
957 957  **0A aa**  ~-~->  same as AT+MOD=aa
... ... @@ -967,13 +967,20 @@
967 967  
968 968  * (((
969 969  (% style="color:#037691" %)**AT Command**
971 +)))
970 970  
973 +(% class="box infomessage" %)
971 971  (((
972 -**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**  m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
975 +(((
976 +**AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
973 973  )))
974 974  )))
975 975  
976 976  (((
981 +m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
982 +)))
983 +
984 +(((
977 977  
978 978  )))
979 979  
... ... @@ -1060,9 +1060,10 @@
1060 1060  
1061 1061  * (% style="color:#037691" %)**AT Command:**
1062 1062  
1063 -**AT+PAYVER:  **Set PAYVER field = 1
1071 +**AT+PAYVER: Set PAYVER field = 1**
1064 1064  
1065 1065  
1074 +
1066 1066  * (% style="color:#037691" %)**Downlink Payload:**
1067 1067  
1068 1068  **0xAE 01**  ~-~-> Set PAYVER field =  0x01
... ... @@ -1090,11 +1090,11 @@
1090 1090  (% style="color:#037691" %)**AT Command:**
1091 1091  )))
1092 1092  
1093 -**AT+COMMANDx:  Configure RS485 read command to sensor.**
1102 +**AT+COMMANDx: Configure RS485 read command to sensor.**
1094 1094  
1095 -**AT+DATACUTx:  Configure how to handle return from RS485 devices.**
1104 +**AT+DATACUTx: Configure how to handle return from RS485 devices.**
1096 1096  
1097 -**AT+SEARCHx:  Configure search command**
1106 +**AT+SEARCHx: Configure search command**
1098 1098  
1099 1099  
1100 1100  * (((
... ... @@ -1206,8 +1206,6 @@
1206 1206  )))
1207 1207  
1208 1208  (((
1209 -
1210 -
1211 1211  **Example:**
1212 1212  )))
1213 1213  
... ... @@ -1254,11 +1254,14 @@
1254 1254  
1255 1255  * (((
1256 1256  (% style="color:#037691" %)**AT Command:**
1264 +)))
1257 1257  
1266 +(% class="box infomessage" %)
1267 +(((
1268 +(((
1258 1258  **AT+CMDDLaa=hex(bb cc)**
1259 -
1260 -
1261 1261  )))
1271 +)))
1262 1262  
1263 1263  (((
1264 1264  **Example:**
... ... @@ -1307,11 +1307,21 @@
1307 1307  
1308 1308  * (((
1309 1309  (% style="color:#037691" %)**AT Command:**
1320 +)))
1310 1310  
1322 +(% class="box infomessage" %)
1323 +(((
1324 +(((
1311 1311  **AT+DATAUP=0**
1326 +)))
1327 +)))
1312 1312  
1329 +(% class="box infomessage" %)
1330 +(((
1331 +(((
1313 1313  **AT+DATAUP=1**
1314 1314  )))
1334 +)))
1315 1315  
1316 1316  (((
1317 1317  
... ... @@ -1403,24 +1403,22 @@
1403 1403  )))
1404 1404  
1405 1405  (((
1406 -
1407 -
1408 -* Set Baud Rate:
1426 +Set Baud Rate:
1409 1409  )))
1410 1410  
1429 +
1411 1411  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1412 1412  
1413 -
1414 -* Set UART Parity
1415 -
1432 +Set UART Parity
1416 1416  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1417 1417  
1418 1418  
1419 -* Set STOPBIT
1436 +Set STOPBIT
1420 1420  
1421 1421  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1422 1422  
1423 1423  
1441 +
1424 1424  * (((
1425 1425  (% style="color:#037691" %)**Downlink Payload:**
1426 1426  )))
... ... @@ -1430,8 +1430,6 @@
1430 1430  )))
1431 1431  
1432 1432  (((
1433 -
1434 -
1435 1435  **Example:**
1436 1436  )))
1437 1437