Last modified by Xiaoling on 2025/04/23 15:57

From version 44.20
edited by Xiaoling
on 2022/06/14 10:13
Change comment: There is no comment for this version
To version 44.23
edited by Xiaoling
on 2022/06/14 10:23
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -383,7 +383,6 @@
383 383  )))
384 384  )))
385 385  
386 -
387 387  === 3.3.2 Configure sensors ===
388 388  
389 389  (((
... ... @@ -898,7 +898,7 @@
898 898  )))
899 899  
900 900  (((
901 -{{{}}}}
900 +}
902 902  
903 903  
904 904  )))
... ... @@ -926,6 +926,10 @@
926 926  
927 927  * (((
928 928  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
928 +
929 +
930 +
931 +
929 929  )))
930 930  
931 931  === 3.5.1 Common Commands: ===
... ... @@ -941,21 +941,17 @@
941 941  
942 942  RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
943 943  
944 -* **AT Command**
947 +* (% style="color:#037691" %)**AT Command**
945 945  
946 -(% class="box infomessage" %)
947 -(((
949 +
948 948  **AT+MOD=1** ~/~/ Set to support RS485-MODBUS type sensors. User can connect multiply RS485 , Modbus sensors to the A / B pins.
949 -)))
950 950  
951 -(% class="box infomessage" %)
952 -(((
953 953  **AT+MOD=2** ~/~/ Set to support TTL Level sensors, User can connect one TTL Sensor to the TXD/RXD/GND pins.
954 -)))
955 955  
956 956  
957 -* **Downlink Payload**
958 958  
956 +* (% style="color:#037691" %)**Downlink Payload**
957 +
959 959  **0A aa**  ~-~->  same as AT+MOD=aa
960 960  
961 961  
... ... @@ -968,7 +968,7 @@
968 968  )))
969 969  
970 970  * (((
971 -**AT Command**
970 +(% style="color:#037691" %)**AT Command**
972 972  )))
973 973  
974 974  (% class="box infomessage" %)
... ... @@ -987,7 +987,7 @@
987 987  )))
988 988  
989 989  * (((
990 -**Downlink Payload**
989 +(% style="color:#037691" %)**Downlink Payload**
991 991  )))
992 992  
993 993  (((
... ... @@ -1067,16 +1067,14 @@
1067 1067  
1068 1068  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
1069 1069  
1070 -* **AT Command:**
1069 +* (% style="color:#037691" %)**AT Command:**
1071 1071  
1072 -(% class="box infomessage" %)
1073 -(((
1074 1074  **AT+PAYVER: Set PAYVER field = 1**
1075 -)))
1076 1076  
1077 1077  
1078 -* **Downlink Payload:**
1079 1079  
1075 +* (% style="color:#037691" %)**Downlink Payload:**
1076 +
1080 1080  **0xAE 01**  ~-~-> Set PAYVER field =  0x01
1081 1081  
1082 1082  **0xAE 0F**   ~-~-> Set PAYVER field =  0x0F
... ... @@ -1099,36 +1099,18 @@
1099 1099  )))
1100 1100  
1101 1101  * (((
1102 -**AT Command:**
1099 +(% style="color:#037691" %)**AT Command:**
1103 1103  )))
1104 1104  
1105 -(% class="box infomessage" %)
1106 -(((
1107 -(((
1108 1108  **AT+COMMANDx: Configure RS485 read command to sensor.**
1109 -)))
1110 -)))
1111 1111  
1112 -(% class="box infomessage" %)
1113 -(((
1114 -(((
1115 1115  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
1116 -)))
1117 -)))
1118 1118  
1119 -(% class="box infomessage" %)
1120 -(((
1121 -(((
1122 1122  **AT+SEARCHx: Configure search command**
1123 -)))
1124 -)))
1125 1125  
1126 -(((
1127 -
1128 -)))
1129 1129  
1130 1130  * (((
1131 -**Downlink Payload:**
1110 +(% style="color:#037691" %)**Downlink Payload:**
1132 1132  )))
1133 1133  
1134 1134  (((
... ... @@ -1220,7 +1220,7 @@
1220 1220  )))
1221 1221  
1222 1222  (((
1223 -**AT+MBFUN has only two value:**
1202 +(% style="color:#037691" %)**AT+MBFUN has only two value:**
1224 1224  )))
1225 1225  
1226 1226  * (((
... ... @@ -1256,7 +1256,7 @@
1256 1256  
1257 1257  
1258 1258  * (((
1259 -**Downlink Commands:**
1238 +(% style="color:#037691" %)**Downlink Commands:**
1260 1260  )))
1261 1261  
1262 1262  (((
... ... @@ -1281,7 +1281,7 @@
1281 1281  )))
1282 1282  
1283 1283  * (((
1284 -**AT Command:**
1263 +(% style="color:#037691" %)**AT Command:**
1285 1285  )))
1286 1286  
1287 1287  (% class="box infomessage" %)
... ... @@ -1304,7 +1304,7 @@
1304 1304  )))
1305 1305  
1306 1306  * (((
1307 -**Downlink Payload:**
1286 +(% style="color:#037691" %)**Downlink Payload:**
1308 1308  )))
1309 1309  
1310 1310  (((
... ... @@ -1337,7 +1337,7 @@
1337 1337  )))
1338 1338  
1339 1339  * (((
1340 -**AT Command:**
1319 +(% style="color:#037691" %)**AT Command:**
1341 1341  )))
1342 1342  
1343 1343  (% class="box infomessage" %)
... ... @@ -1359,7 +1359,7 @@
1359 1359  )))
1360 1360  
1361 1361  * (((
1362 -**Downlink Payload:**
1341 +(% style="color:#037691" %)**Downlink Payload:**
1363 1363  )))
1364 1364  
1365 1365  (((
... ... @@ -1377,7 +1377,7 @@
1377 1377  
1378 1378  Ask device to send an uplink immediately.
1379 1379  
1380 -* **Downlink Payload:**
1359 +* (% style="color:#037691" %)**Downlink Payload:**
1381 1381  
1382 1382  **0x08 FF**, RS485-BL will immediately send an uplink.
1383 1383  
... ... @@ -1395,7 +1395,7 @@
1395 1395  )))
1396 1396  
1397 1397  * (((
1398 -**AT Command:**
1377 +(% style="color:#037691" %)**AT Command:**
1399 1399  )))
1400 1400  
1401 1401  (((
... ... @@ -1423,7 +1423,7 @@
1423 1423  )))
1424 1424  
1425 1425  * (((
1426 -**Downlink Payload:**
1405 +(% style="color:#037691" %)**Downlink Payload:**
1427 1427  )))
1428 1428  
1429 1429  (((
... ... @@ -1440,7 +1440,7 @@
1440 1440  )))
1441 1441  
1442 1442  * (((
1443 -**AT Command:**
1422 +(% style="color:#037691" %)**AT Command:**
1444 1444  )))
1445 1445  
1446 1446  (((
... ... @@ -1447,23 +1447,21 @@
1447 1447  Set Baud Rate:
1448 1448  )))
1449 1449  
1450 -(% class="box infomessage" %)
1451 -(((
1452 -(((
1429 +
1453 1453  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1454 1454  
1455 1455  Set UART Parity
1456 1456  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1457 1457  
1435 +
1458 1458  Set STOPBIT
1459 1459  
1460 1460  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1461 -)))
1462 -)))
1463 1463  
1464 1464  
1441 +
1465 1465  * (((
1466 -**Downlink Payload:**
1443 +(% style="color:#037691" %)**Downlink Payload:**
1467 1467  )))
1468 1468  
1469 1469  (((
... ... @@ -1499,7 +1499,7 @@
1499 1499  )))
1500 1500  
1501 1501  * (((
1502 -**AT Command:**
1479 +(% style="color:#037691" %)**AT Command:**
1503 1503  )))
1504 1504  
1505 1505  (((
... ... @@ -1519,7 +1519,7 @@
1519 1519  )))
1520 1520  
1521 1521  * (((
1522 -**LoRaWAN Downlink Command:**
1499 +(% style="color:#037691" %)**LoRaWAN Downlink Command:**
1523 1523  )))
1524 1524  
1525 1525  (((
... ... @@ -1538,6 +1538,9 @@
1538 1538  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1539 1539  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1540 1540  
1518 +
1519 +
1520 +
1541 1541  == 3.7 +3V3 Output ==
1542 1542  
1543 1543  (((