Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1652947681187-144.png||height=" 404" width="404"]]2 +[[image:1652947681187-144.png||height="385" width="385"]] 3 3 4 4 5 5 6 6 7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 + 9 + 10 + 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -193,7 +193,6 @@ 193 193 194 194 [[image:1652953414711-647.png||height="337" width="723"]] 195 195 196 - 197 197 ((( 198 198 The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. 199 199 ))) ... ... @@ -203,7 +203,7 @@ 203 203 ))) 204 204 205 205 ((( 206 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-BL.209 +**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-BL. 207 207 ))) 208 208 209 209 ((( ... ... @@ -212,13 +212,12 @@ 212 212 213 213 [[image:1652953462722-299.png]] 214 214 215 - 216 216 ((( 217 217 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: 218 218 ))) 219 219 220 220 ((( 221 - **Add APP EUI in the application.**223 +Add APP EUI in the application. 222 222 ))) 223 223 224 224 ... ... @@ -230,20 +230,17 @@ 230 230 231 231 [[image:image-20220519174512-4.png]] 232 232 233 - 234 234 You can also choose to create the device manually. 235 235 236 236 [[image:1652953542269-423.png||height="710" width="723"]] 237 237 238 - 239 239 Add APP KEY and DEV EUI 240 240 241 241 [[image:1652953553383-907.png||height="514" width="724"]] 242 242 243 243 244 - 245 245 ((( 246 - (% style="color:blue" %)**Step 2**(%%): Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.245 +**Step 2**: Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 247 247 ))) 248 248 249 249 [[image:1652953568895-172.png||height="232" width="724"]] ... ... @@ -284,28 +284,28 @@ 284 284 ))) 285 285 286 286 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 287 -|=(% style="width: 80px;" %)(((286 +|=(% style="width: 120px;" %)((( 288 288 ((( 289 289 **AT Commands** 290 290 ))) 291 -)))|=(% style="width: 210px;" %)(((290 +)))|=(% style="width: 190px;" %)((( 292 292 ((( 293 293 **Description** 294 294 ))) 295 -)))|=(% style="width: 210px;" %)(((294 +)))|=(% style="width: 190px;" %)((( 296 296 ((( 297 297 **Example** 298 298 ))) 299 299 ))) 300 -|(% style="width: 80px" %)(((299 +|(% style="width:120px" %)((( 301 301 ((( 302 302 AT+BAUDR 303 303 ))) 304 -)))|(% style="width: 210px" %)(((303 +)))|(% style="width:190px" %)((( 305 305 ((( 306 306 Set the baud rate (for RS485 connection). Default Value is: 9600. 307 307 ))) 308 -)))|(% style="width: 210px" %)(((307 +)))|(% style="width:190px" %)((( 309 309 ((( 310 310 ((( 311 311 AT+BAUDR=9600 ... ... @@ -318,11 +318,11 @@ 318 318 ))) 319 319 ))) 320 320 ))) 321 -|(% style="width: 80px" %)(((320 +|(% style="width:120px" %)((( 322 322 ((( 323 323 AT+PARITY 324 324 ))) 325 -)))|(% style="width: 210px" %)(((324 +)))|(% style="width:190px" %)((( 326 326 ((( 327 327 ((( 328 328 Set UART parity (for RS485 connection) ... ... @@ -334,7 +334,7 @@ 334 334 Default Value is: no parity. 335 335 ))) 336 336 ))) 337 -)))|(% style="width: 210px" %)(((336 +)))|(% style="width:190px" %)((( 338 338 ((( 339 339 ((( 340 340 AT+PARITY=0 ... ... @@ -347,11 +347,11 @@ 347 347 ))) 348 348 ))) 349 349 ))) 350 -|(% style="width: 80px" %)(((349 +|(% style="width:120px" %)((( 351 351 ((( 352 352 AT+STOPBIT 353 353 ))) 354 -)))|(% style="width: 210px" %)(((353 +)))|(% style="width:190px" %)((( 355 355 ((( 356 356 ((( 357 357 Set serial stopbit (for RS485 connection) ... ... @@ -363,7 +363,7 @@ 363 363 Default Value is: 1bit. 364 364 ))) 365 365 ))) 366 -)))|(% style="width: 210px" %)(((365 +)))|(% style="width:190px" %)((( 367 367 ((( 368 368 ((( 369 369 AT+STOPBIT=0 for 1bit ... ... @@ -384,6 +384,7 @@ 384 384 ))) 385 385 386 386 386 + 387 387 === 3.3.2 Configure sensors === 388 388 389 389 ((( ... ... @@ -395,20 +395,14 @@ 395 395 ))) 396 396 397 397 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 398 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 399 -|AT+CFGDEV|(% style="width:80px" %)((( 400 -((( 398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 +|AT+CFGDEV|(% style="width:120px" %)((( 401 401 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 402 -))) 403 403 404 -((( 405 405 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 406 -))) 407 407 408 -((( 409 409 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 410 -))) 411 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 412 412 413 413 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 414 414 ... ... @@ -434,22 +434,18 @@ 434 434 435 435 ((( 436 436 During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 437 - 438 - 439 439 ))) 440 440 441 441 ((( 442 - (% style="color:blue" %)**Command from RS485-BL to Sensor:**434 +**Command from RS485-BL to Sensor:** 443 443 ))) 444 444 445 445 ((( 446 446 RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar. 447 - 448 - 449 449 ))) 450 450 451 451 ((( 452 - (% style="color:blue" %)**Handle return from sensors to RS485-BL**:442 +**Handle return from sensors to RS485-BL**: 453 453 ))) 454 454 455 455 ((( ... ... @@ -457,17 +457,15 @@ 457 457 ))) 458 458 459 459 * ((( 460 - (% style="color:blue" %)**AT+DATACUT**450 +**AT+DATACUT** 461 461 ))) 462 462 463 463 ((( 464 464 When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command. 465 - 466 - 467 467 ))) 468 468 469 469 * ((( 470 - (% style="color:blue" %)**AT+SEARCH**458 +**AT+SEARCH** 471 471 ))) 472 472 473 473 ((( ... ... @@ -475,9 +475,7 @@ 475 475 ))) 476 476 477 477 ((( 478 - 479 - 480 -(% style="color:blue" %)**Define wait timeout:** 466 +**Define wait timeout:** 481 481 ))) 482 482 483 483 ((( ... ... @@ -489,8 +489,6 @@ 489 489 ))) 490 490 491 491 ((( 492 - 493 - 494 494 **Examples:** 495 495 ))) 496 496 ... ... @@ -548,8 +548,6 @@ 548 548 ))) 549 549 550 550 ((( 551 - 552 - 553 553 **Examples:** 554 554 ))) 555 555 ... ... @@ -567,8 +567,6 @@ 567 567 568 568 ((( 569 569 [[image:1653271044481-711.png]] 570 - 571 - 572 572 ))) 573 573 574 574 ((( ... ... @@ -609,13 +609,11 @@ 609 609 ))) 610 610 611 611 ((( 612 - 613 - 614 614 **Examples:** 615 615 ))) 616 616 617 617 * ((( 618 - (% style="color:blue" %)**Grab bytes:**596 +Grab bytes: 619 619 ))) 620 620 621 621 ((( ... ... @@ -627,7 +627,7 @@ 627 627 ))) 628 628 629 629 * ((( 630 - (% style="color:blue" %)**Grab a section.**608 +Grab a section. 631 631 ))) 632 632 633 633 ((( ... ... @@ -639,13 +639,11 @@ 639 639 ))) 640 640 641 641 * ((( 642 - (% style="color:blue" %)**Grab different sections.**620 +Grab different sections. 643 643 ))) 644 644 645 645 ((( 646 646 [[image:1653271657255-576.png||height="305" width="730"]] 647 - 648 - 649 649 ))) 650 650 651 651 ((( ... ... @@ -773,8 +773,6 @@ 773 773 ))) 774 774 1. ((( 775 775 DATA: Valid value: max 6 bytes(US915 version here, Notice*!) for each uplink so each uplink <= 11 bytes. For the last uplink, DATA will might less than 6 bytes 776 - 777 - 778 778 ))) 779 779 780 780 [[image:1653272817147-600.png||height="437" width="717"]] ... ... @@ -898,7 +898,7 @@ 898 898 ))) 899 899 900 900 ((( 901 - **}**875 +{{{}}}} 902 902 903 903 904 904 ))) ... ... @@ -928,6 +928,8 @@ 928 928 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 929 929 ))) 930 930 905 + 906 + 931 931 === 3.5.1 Common Commands: === 932 932 933 933 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1255,13 +1255,9 @@ 1255 1255 [[image:1654133954153-643.png]] 1256 1256 1257 1257 1258 -* ((( 1259 -**Downlink Commands:** 1260 -))) 1234 +* **Downlink Commands:** 1261 1261 1262 -((( 1263 1263 **A9 aa** ~-~-> Same as AT+MBFUN=aa 1264 -))) 1265 1265 1266 1266 1267 1267 ... ... @@ -1268,60 +1268,32 @@ 1268 1268 1269 1269 ==== **RS485 command timeout** ==== 1270 1270 1271 -((( 1272 1272 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 1273 -))) 1274 1274 1275 -((( 1276 1276 Default value: 0, range: 0 ~~ 5 seconds 1277 -))) 1278 1278 1279 -((( 1280 - 1281 -))) 1282 1282 1283 -* ((( 1284 -**AT Command:** 1285 -))) 1248 +* **AT Command:** 1286 1286 1287 1287 (% class="box infomessage" %) 1288 1288 ((( 1289 -((( 1290 1290 **AT+CMDDLaa=hex(bb cc)** 1291 1291 ))) 1292 -))) 1293 1293 1294 -((( 1295 1295 **Example:** 1296 -))) 1297 1297 1298 -((( 1299 1299 **AT+CMDDL1=1000** to send the open time to 1000ms 1300 -))) 1301 1301 1302 -((( 1303 - 1304 -))) 1305 1305 1306 -* ((( 1307 -**Downlink Payload:** 1308 -))) 1260 +* **Downlink Payload:** 1309 1309 1310 -((( 1311 1311 0x AA aa bb cc 1312 -))) 1313 1313 1314 -((( 1315 1315 Same as: AT+CMDDLaa=hex(bb cc) 1316 -))) 1317 1317 1318 -((( 1319 1319 **Example:** 1320 -))) 1321 1321 1322 -((( 1323 1323 **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 1324 -))) 1325 1325 1326 1326 1327 1327 ... ... @@ -1328,47 +1328,28 @@ 1328 1328 1329 1329 ==== **Uplink payload mode** ==== 1330 1330 1331 -((( 1332 1332 Define to use one uplink or multiple uplinks for the sampling. 1333 -))) 1334 1334 1335 -((( 1336 1336 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 1337 -))) 1338 1338 1339 -* ((( 1340 -**AT Command:** 1341 -))) 1279 +* **AT Command:** 1342 1342 1343 1343 (% class="box infomessage" %) 1344 1344 ((( 1345 -((( 1346 1346 **AT+DATAUP=0** 1347 1347 ))) 1348 -))) 1349 1349 1350 1350 (% class="box infomessage" %) 1351 1351 ((( 1352 -((( 1353 1353 **AT+DATAUP=1** 1354 1354 ))) 1355 -))) 1356 1356 1357 -((( 1358 - 1359 -))) 1360 1360 1361 -* ((( 1362 -**Downlink Payload:** 1363 -))) 1292 +* **Downlink Payload:** 1364 1364 1365 -((( 1366 1366 **0xAD 00** **~-~->** Same as AT+DATAUP=0 1367 -))) 1368 1368 1369 -((( 1370 1370 **0xAD 01** **~-~->** Same as AT+DATAUP=1 1371 -))) 1372 1372 1373 1373 1374 1374 ... ... @@ -1386,49 +1386,26 @@ 1386 1386 1387 1387 ==== **Clear RS485 Command** ==== 1388 1388 1389 -((( 1390 1390 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1391 -))) 1392 1392 1393 -((( 1394 - 1395 -))) 1396 1396 1397 -* ((( 1398 -**AT Command:** 1399 -))) 1317 +* **AT Command:** 1400 1400 1401 1401 ((( 1402 1402 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1403 1403 ))) 1404 1404 1405 -((( 1406 1406 Example screen shot after clear all RS485 commands. 1407 -))) 1408 1408 1409 -((( 1410 - 1411 -))) 1412 1412 1413 -((( 1414 1414 The uplink screen shot is: 1415 -))) 1416 1416 1417 -((( 1418 1418 [[image:1654134704555-320.png]] 1419 -))) 1420 1420 1421 -((( 1422 - 1423 -))) 1424 1424 1425 -* ((( 1426 -**Downlink Payload:** 1427 -))) 1331 +* **Downlink Payload:** 1428 1428 1429 -((( 1430 1430 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1431 -))) 1432 1432 1433 1433 1434 1434 ... ... @@ -1435,59 +1435,44 @@ 1435 1435 1436 1436 ==== **Set Serial Communication Parameters** ==== 1437 1437 1438 -((( 1439 1439 Set the Rs485 serial communication parameters: 1440 -))) 1441 1441 1442 -* ((( 1443 -**AT Command:** 1444 -))) 1342 +* **AT Command:** 1445 1445 1446 -((( 1447 1447 Set Baud Rate: 1448 -))) 1449 1449 1450 1450 (% class="box infomessage" %) 1451 1451 ((( 1452 -((( 1453 1453 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1349 +))) 1454 1454 1455 1455 Set UART Parity 1352 + 1353 +(% class="box infomessage" %) 1354 +((( 1456 1456 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1356 +))) 1457 1457 1458 1458 Set STOPBIT 1459 1459 1360 +(% class="box infomessage" %) 1361 +((( 1460 1460 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1461 1461 ))) 1462 -))) 1463 1463 1464 1464 1465 -* ((( 1466 -**Downlink Payload:** 1467 -))) 1366 +* **Downlink Payload:** 1468 1468 1469 -((( 1470 1470 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1471 -))) 1472 1472 1473 -((( 1474 1474 **Example:** 1475 -))) 1476 1476 1477 -* ((( 1478 -A7 01 00 60 same as AT+BAUDR=9600 1479 -))) 1480 -* ((( 1481 -A7 01 04 80 same as AT+BAUDR=115200 1482 -))) 1372 +* A7 01 00 60 same as AT+BAUDR=9600 1373 +* A7 01 04 80 same as AT+BAUDR=115200 1483 1483 1484 -((( 1485 1485 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1486 -))) 1487 1487 1488 -((( 1489 1489 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1490 -))) 1491 1491 1492 1492 1493 1493 ... ... @@ -1494,41 +1494,22 @@ 1494 1494 1495 1495 ==== **Control output power duration** ==== 1496 1496 1497 -((( 1498 1498 User can set the output power duration before each sampling. 1499 -))) 1500 1500 1501 -* ((( 1502 -**AT Command:** 1503 -))) 1386 +* **AT Command:** 1504 1504 1505 -((( 1506 1506 **Example:** 1507 -))) 1508 1508 1509 -((( 1510 1510 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1511 -))) 1512 1512 1513 -((( 1514 1514 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1515 -))) 1516 1516 1517 -((( 1518 - 1519 -))) 1520 1520 1521 -* ((( 1522 -**LoRaWAN Downlink Command:** 1523 -))) 1395 +* **LoRaWAN Downlink Command:** 1524 1524 1525 -((( 1526 1526 **07 01 aa bb** Same as AT+5VT=(aa bb) 1527 -))) 1528 1528 1529 -((( 1530 1530 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1531 -))) 1532 1532 1533 1533 1534 1534 ... ... @@ -1538,6 +1538,8 @@ 1538 1538 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1539 1539 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1540 1540 1409 + 1410 + 1541 1541 == 3.7 +3V3 Output == 1542 1542 1543 1543 ((( ... ... @@ -1615,14 +1615,22 @@ 1615 1615 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1616 1616 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1617 1617 1488 + 1489 + 1618 1618 == 3.10 Switch Jumper == 1619 1619 1620 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1621 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1622 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1492 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1493 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1494 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1495 +ISP position: Upgrade firmware via UART 1496 + 1623 1623 Flash position: Configure device, check running status. 1624 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1498 +))) 1499 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1500 +5V position: set to compatible with 5v I/O. 1501 + 1625 1625 3.3v position: set to compatible with 3.3v I/O., 1503 +))) 1626 1626 1627 1627 ((( 1628 1628 **+3.3V**: is always ON ... ... @@ -1670,7 +1670,15 @@ 1670 1670 (% class="box infomessage" %) 1671 1671 ((( 1672 1672 **AT+FDR** 1551 +))) 1552 + 1553 +(% class="box infomessage" %) 1554 +((( 1673 1673 **AT+NJM=0** 1556 +))) 1557 + 1558 +(% class="box infomessage" %) 1559 +((( 1674 1674 **ATZ** 1675 1675 ))) 1676 1676 ... ... @@ -1812,6 +1812,8 @@ 1812 1812 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1813 1813 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1814 1814 1701 + 1702 + 1815 1815 = 9. Packing Info = 1816 1816 1817 1817 (((