Last modified by Xiaoling on 2025/04/23 15:57

From version 44.17
edited by Xiaoling
on 2022/06/14 10:11
Change comment: There is no comment for this version
To version 42.23
edited by Xiaoling
on 2022/06/06 14:27
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,9 +1,13 @@
1 1  (% style="text-align:center" %)
2 -[[image:1652947681187-144.png||height="404" width="404"]]
2 +[[image:1652947681187-144.png||height="385" width="385"]]
3 3  
4 4  
5 5  
6 6  
7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual**
8 +
9 +
10 +
7 7  **Table of Contents:**
8 8  
9 9  {{toc/}}
... ... @@ -91,6 +91,7 @@
91 91  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
92 92  
93 93  
98 +
94 94  == 1.3 Features ==
95 95  
96 96  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -103,6 +103,7 @@
103 103  * Support Interrupt uplink
104 104  
105 105  
111 +
106 106  == 1.4 Applications ==
107 107  
108 108  * Smart Buildings & Home Automation
... ... @@ -113,6 +113,7 @@
113 113  * Smart Factory
114 114  
115 115  
122 +
116 116  == 1.5 Firmware Change log ==
117 117  
118 118  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -196,7 +196,6 @@
196 196  
197 197  [[image:1652953414711-647.png||height="337" width="723"]]
198 198  
199 -
200 200  (((
201 201  The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method.
202 202  )))
... ... @@ -206,7 +206,7 @@
206 206  )))
207 207  
208 208  (((
209 -(% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-BL.
215 +**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-BL.
210 210  )))
211 211  
212 212  (((
... ... @@ -215,13 +215,12 @@
215 215  
216 216  [[image:1652953462722-299.png]]
217 217  
218 -
219 219  (((
220 220  User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
221 221  )))
222 222  
223 223  (((
224 -**Add APP EUI in the application.**
229 +Add APP EUI in the application.
225 225  )))
226 226  
227 227  
... ... @@ -233,20 +233,17 @@
233 233  
234 234  [[image:image-20220519174512-4.png]]
235 235  
236 -
237 237  You can also choose to create the device manually.
238 238  
239 239  [[image:1652953542269-423.png||height="710" width="723"]]
240 240  
241 -
242 242  Add APP KEY and DEV EUI
243 243  
244 244  [[image:1652953553383-907.png||height="514" width="724"]]
245 245  
246 246  
247 -
248 248  (((
249 -(% style="color:blue" %)**Step 2**(%%): Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
251 +**Step 2**: Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
250 250  )))
251 251  
252 252  [[image:1652953568895-172.png||height="232" width="724"]]
... ... @@ -401,17 +401,11 @@
401 401  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
402 402  |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
403 403  |AT+CFGDEV|(% style="width:80px" %)(((
404 -(((
405 405  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
406 -)))
407 407  
408 -(((
409 409  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
410 -)))
411 411  
412 -(((
413 413  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
414 -)))
415 415  )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
416 416  
417 417  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
... ... @@ -438,22 +438,18 @@
438 438  
439 439  (((
440 440  During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads.
441 -
442 -
443 443  )))
444 444  
445 445  (((
446 -(% style="color:blue" %)**Command from RS485-BL to Sensor:**
440 +**Command from RS485-BL to Sensor:**
447 447  )))
448 448  
449 449  (((
450 450  RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar.
451 -
452 -
453 453  )))
454 454  
455 455  (((
456 -(% style="color:blue" %)**Handle return from sensors to RS485-BL**:
448 +**Handle return from sensors to RS485-BL**:
457 457  )))
458 458  
459 459  (((
... ... @@ -461,17 +461,15 @@
461 461  )))
462 462  
463 463  * (((
464 -(% style="color:blue" %)**AT+DATACUT**
456 +**AT+DATACUT**
465 465  )))
466 466  
467 467  (((
468 468  When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command.
469 -
470 -
471 471  )))
472 472  
473 473  * (((
474 -(% style="color:blue" %)**AT+SEARCH**
464 +**AT+SEARCH**
475 475  )))
476 476  
477 477  (((
... ... @@ -479,9 +479,7 @@
479 479  )))
480 480  
481 481  (((
482 -
483 -
484 -(% style="color:blue" %)**Define wait timeout:**
472 +**Define wait timeout:**
485 485  )))
486 486  
487 487  (((
... ... @@ -493,8 +493,6 @@
493 493  )))
494 494  
495 495  (((
496 -
497 -
498 498  **Examples:**
499 499  )))
500 500  
... ... @@ -552,8 +552,6 @@
552 552  )))
553 553  
554 554  (((
555 -
556 -
557 557  **Examples:**
558 558  )))
559 559  
... ... @@ -571,8 +571,6 @@
571 571  
572 572  (((
573 573  [[image:1653271044481-711.png]]
574 -
575 -
576 576  )))
577 577  
578 578  (((
... ... @@ -613,8 +613,6 @@
613 613  )))
614 614  
615 615  (((
616 -
617 -
618 618  **Examples:**
619 619  )))
620 620  
... ... @@ -928,6 +928,7 @@
928 928  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
929 929  )))
930 930  
911 +
931 931  === 3.5.1 Common Commands: ===
932 932  
933 933  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1451,16 +1451,34 @@
1451 1451  (((
1452 1452  (((
1453 1453  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1435 +)))
1436 +)))
1454 1454  
1438 +(((
1455 1455  Set UART Parity
1440 +)))
1441 +
1442 +(% class="box infomessage" %)
1443 +(((
1444 +(((
1456 1456  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1446 +)))
1447 +)))
1457 1457  
1449 +(((
1458 1458  Set STOPBIT
1451 +)))
1459 1459  
1453 +(% class="box infomessage" %)
1454 +(((
1455 +(((
1460 1460  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1461 1461  )))
1462 1462  )))
1463 1463  
1460 +(((
1461 +
1462 +)))
1464 1464  
1465 1465  * (((
1466 1466  **Downlink Payload:**
... ... @@ -1538,6 +1538,7 @@
1538 1538  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1539 1539  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1540 1540  
1540 +
1541 1541  == 3.7 +3V3 Output ==
1542 1542  
1543 1543  (((
... ... @@ -1615,6 +1615,7 @@
1615 1615  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1616 1616  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1617 1617  
1618 +
1618 1618  == 3.10 Switch Jumper ==
1619 1619  
1620 1620  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %)
... ... @@ -1670,7 +1670,15 @@
1670 1670  (% class="box infomessage" %)
1671 1671  (((
1672 1672  **AT+FDR**
1674 +)))
1675 +
1676 +(% class="box infomessage" %)
1677 +(((
1673 1673  **AT+NJM=0**
1679 +)))
1680 +
1681 +(% class="box infomessage" %)
1682 +(((
1674 1674  **ATZ**
1675 1675  )))
1676 1676  
... ... @@ -1812,6 +1812,7 @@
1812 1812  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1813 1813  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1814 1814  
1824 +
1815 1815  = 9. Packing Info =