Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1652947681187-144.png||height=" 404" width="404"]]2 +[[image:1652947681187-144.png||height="385" width="385"]] 3 3 4 4 5 5 6 6 7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 + 9 + 10 + 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -90,7 +90,6 @@ 90 90 * 127 dB Dynamic Range RSSI. 91 91 * Automatic RF Sense and CAD with ultra-fast AFC. 92 92 93 - 94 94 == 1.3 Features == 95 95 96 96 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -102,7 +102,6 @@ 102 102 * Support Modbus protocol 103 103 * Support Interrupt uplink 104 104 105 - 106 106 == 1.4 Applications == 107 107 108 108 * Smart Buildings & Home Automation ... ... @@ -112,7 +112,6 @@ 112 112 * Smart Cities 113 113 * Smart Factory 114 114 115 - 116 116 == 1.5 Firmware Change log == 117 117 118 118 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -196,7 +196,6 @@ 196 196 197 197 [[image:1652953414711-647.png||height="337" width="723"]] 198 198 199 - 200 200 ((( 201 201 The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. 202 202 ))) ... ... @@ -206,7 +206,7 @@ 206 206 ))) 207 207 208 208 ((( 209 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN V3 with the OTAA keys from RS485-BL.209 +**Step 1**: Create a device in TTN V3 with the OTAA keys from RS485-BL. 210 210 ))) 211 211 212 212 ((( ... ... @@ -215,13 +215,12 @@ 215 215 216 216 [[image:1652953462722-299.png]] 217 217 218 - 219 219 ((( 220 220 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: 221 221 ))) 222 222 223 223 ((( 224 - **Add APP EUI in the application.**223 +Add APP EUI in the application. 225 225 ))) 226 226 227 227 ... ... @@ -233,20 +233,17 @@ 233 233 234 234 [[image:image-20220519174512-4.png]] 235 235 236 - 237 237 You can also choose to create the device manually. 238 238 239 239 [[image:1652953542269-423.png||height="710" width="723"]] 240 240 241 - 242 242 Add APP KEY and DEV EUI 243 243 244 244 [[image:1652953553383-907.png||height="514" width="724"]] 245 245 246 246 247 - 248 248 ((( 249 - (% style="color:blue" %)**Step 2**(%%): Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.245 +**Step 2**: Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 250 250 ))) 251 251 252 252 [[image:1652953568895-172.png||height="232" width="724"]] ... ... @@ -287,28 +287,28 @@ 287 287 ))) 288 288 289 289 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 290 -|=(% style="width: 80px;" %)(((286 +|=(% style="width: 120px;" %)((( 291 291 ((( 292 292 **AT Commands** 293 293 ))) 294 -)))|=(% style="width: 210px;" %)(((290 +)))|=(% style="width: 190px;" %)((( 295 295 ((( 296 296 **Description** 297 297 ))) 298 -)))|=(% style="width: 210px;" %)(((294 +)))|=(% style="width: 190px;" %)((( 299 299 ((( 300 300 **Example** 301 301 ))) 302 302 ))) 303 -|(% style="width: 80px" %)(((299 +|(% style="width:120px" %)((( 304 304 ((( 305 305 AT+BAUDR 306 306 ))) 307 -)))|(% style="width: 210px" %)(((303 +)))|(% style="width:190px" %)((( 308 308 ((( 309 309 Set the baud rate (for RS485 connection). Default Value is: 9600. 310 310 ))) 311 -)))|(% style="width: 210px" %)(((307 +)))|(% style="width:190px" %)((( 312 312 ((( 313 313 ((( 314 314 AT+BAUDR=9600 ... ... @@ -321,11 +321,11 @@ 321 321 ))) 322 322 ))) 323 323 ))) 324 -|(% style="width: 80px" %)(((320 +|(% style="width:120px" %)((( 325 325 ((( 326 326 AT+PARITY 327 327 ))) 328 -)))|(% style="width: 210px" %)(((324 +)))|(% style="width:190px" %)((( 329 329 ((( 330 330 ((( 331 331 Set UART parity (for RS485 connection) ... ... @@ -337,7 +337,7 @@ 337 337 Default Value is: no parity. 338 338 ))) 339 339 ))) 340 -)))|(% style="width: 210px" %)(((336 +)))|(% style="width:190px" %)((( 341 341 ((( 342 342 ((( 343 343 AT+PARITY=0 ... ... @@ -350,11 +350,11 @@ 350 350 ))) 351 351 ))) 352 352 ))) 353 -|(% style="width: 80px" %)(((349 +|(% style="width:120px" %)((( 354 354 ((( 355 355 AT+STOPBIT 356 356 ))) 357 -)))|(% style="width: 210px" %)(((353 +)))|(% style="width:190px" %)((( 358 358 ((( 359 359 ((( 360 360 Set serial stopbit (for RS485 connection) ... ... @@ -366,7 +366,7 @@ 366 366 Default Value is: 1bit. 367 367 ))) 368 368 ))) 369 -)))|(% style="width: 210px" %)(((365 +)))|(% style="width:190px" %)((( 370 370 ((( 371 371 ((( 372 372 AT+STOPBIT=0 for 1bit ... ... @@ -399,20 +399,14 @@ 399 399 ))) 400 400 401 401 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 402 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 403 -|AT+CFGDEV|(% style="width:80px" %)((( 404 -((( 398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 +|AT+CFGDEV|(% style="width:120px" %)((( 405 405 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 406 -))) 407 407 408 -((( 409 409 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 410 -))) 411 411 412 -((( 413 413 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 414 -))) 415 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 416 416 417 417 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 418 418 ... ... @@ -438,22 +438,18 @@ 438 438 439 439 ((( 440 440 During each sampling, the RS485-BL can support 15 commands to read sensors. And combine the return to one or several uplink payloads. 441 - 442 - 443 443 ))) 444 444 445 445 ((( 446 - (% style="color:blue" %)**Command from RS485-BL to Sensor:**434 +**Command from RS485-BL to Sensor:** 447 447 ))) 448 448 449 449 ((( 450 450 RS485-BL can send out pre-set max 15 strings via **AT+COMMAD1**, **ATCOMMAND2**,…, to **AT+COMMANDF** . All commands are of same grammar. 451 - 452 - 453 453 ))) 454 454 455 455 ((( 456 - (% style="color:blue" %)**Handle return from sensors to RS485-BL**:442 +**Handle return from sensors to RS485-BL**: 457 457 ))) 458 458 459 459 ((( ... ... @@ -461,17 +461,15 @@ 461 461 ))) 462 462 463 463 * ((( 464 - (% style="color:blue" %)**AT+DATACUT**450 +**AT+DATACUT** 465 465 ))) 466 466 467 467 ((( 468 468 When the return value from sensor have fix length and we know which position the valid value we should get, we can use AT+DATACUT command. 469 - 470 - 471 471 ))) 472 472 473 473 * ((( 474 - (% style="color:blue" %)**AT+SEARCH**458 +**AT+SEARCH** 475 475 ))) 476 476 477 477 ((( ... ... @@ -479,9 +479,7 @@ 479 479 ))) 480 480 481 481 ((( 482 - 483 - 484 -(% style="color:blue" %)**Define wait timeout:** 466 +**Define wait timeout:** 485 485 ))) 486 486 487 487 ((( ... ... @@ -493,8 +493,6 @@ 493 493 ))) 494 494 495 495 ((( 496 - 497 - 498 498 **Examples:** 499 499 ))) 500 500 ... ... @@ -552,8 +552,6 @@ 552 552 ))) 553 553 554 554 ((( 555 - 556 - 557 557 **Examples:** 558 558 ))) 559 559 ... ... @@ -894,7 +894,7 @@ 894 894 ))) 895 895 896 896 ((( 897 - **}**875 +{{{}}}} 898 898 899 899 900 900 ))) ... ... @@ -924,6 +924,8 @@ 924 924 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 925 925 ))) 926 926 905 + 906 + 927 927 === 3.5.1 Common Commands: === 928 928 929 929 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1431,59 +1431,44 @@ 1431 1431 1432 1432 ==== **Set Serial Communication Parameters** ==== 1433 1433 1434 -((( 1435 1435 Set the Rs485 serial communication parameters: 1436 -))) 1437 1437 1438 -* ((( 1439 -**AT Command:** 1440 -))) 1416 +* **AT Command:** 1441 1441 1442 -((( 1443 1443 Set Baud Rate: 1444 -))) 1445 1445 1446 1446 (% class="box infomessage" %) 1447 1447 ((( 1448 -((( 1449 1449 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1423 +))) 1450 1450 1451 1451 Set UART Parity 1426 + 1427 +(% class="box infomessage" %) 1428 +((( 1452 1452 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1430 +))) 1453 1453 1454 1454 Set STOPBIT 1455 1455 1434 +(% class="box infomessage" %) 1435 +((( 1456 1456 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1457 1457 ))) 1458 -))) 1459 1459 1460 1460 1461 -* ((( 1462 -**Downlink Payload:** 1463 -))) 1440 +* **Downlink Payload:** 1464 1464 1465 -((( 1466 1466 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1467 -))) 1468 1468 1469 -((( 1470 1470 **Example:** 1471 -))) 1472 1472 1473 -* ((( 1474 -A7 01 00 60 same as AT+BAUDR=9600 1475 -))) 1476 -* ((( 1477 -A7 01 04 80 same as AT+BAUDR=115200 1478 -))) 1446 +* A7 01 00 60 same as AT+BAUDR=9600 1447 +* A7 01 04 80 same as AT+BAUDR=115200 1479 1479 1480 -((( 1481 1481 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1482 -))) 1483 1483 1484 -((( 1485 1485 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1486 -))) 1487 1487 1488 1488 1489 1489 ... ... @@ -1490,41 +1490,22 @@ 1490 1490 1491 1491 ==== **Control output power duration** ==== 1492 1492 1493 -((( 1494 1494 User can set the output power duration before each sampling. 1495 -))) 1496 1496 1497 -* ((( 1498 -**AT Command:** 1499 -))) 1460 +* **AT Command:** 1500 1500 1501 -((( 1502 1502 **Example:** 1503 -))) 1504 1504 1505 -((( 1506 1506 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1507 -))) 1508 1508 1509 -((( 1510 1510 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1511 -))) 1512 1512 1513 -((( 1514 - 1515 -))) 1516 1516 1517 -* ((( 1518 -**LoRaWAN Downlink Command:** 1519 -))) 1469 +* **LoRaWAN Downlink Command:** 1520 1520 1521 -((( 1522 1522 **07 01 aa bb** Same as AT+5VT=(aa bb) 1523 -))) 1524 1524 1525 -((( 1526 1526 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1527 -))) 1528 1528 1529 1529 1530 1530 ... ... @@ -1534,6 +1534,8 @@ 1534 1534 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1535 1535 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1536 1536 1483 + 1484 + 1537 1537 == 3.7 +3V3 Output == 1538 1538 1539 1539 ((( ... ... @@ -1611,14 +1611,22 @@ 1611 1611 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1612 1612 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1613 1613 1562 + 1563 + 1614 1614 == 3.10 Switch Jumper == 1615 1615 1616 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1617 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1618 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1566 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1567 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1568 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1569 +ISP position: Upgrade firmware via UART 1570 + 1619 1619 Flash position: Configure device, check running status. 1620 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1572 +))) 1573 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1574 +5V position: set to compatible with 5v I/O. 1575 + 1621 1621 3.3v position: set to compatible with 3.3v I/O., 1577 +))) 1622 1622 1623 1623 ((( 1624 1624 **+3.3V**: is always ON ... ... @@ -1666,7 +1666,15 @@ 1666 1666 (% class="box infomessage" %) 1667 1667 ((( 1668 1668 **AT+FDR** 1625 +))) 1626 + 1627 +(% class="box infomessage" %) 1628 +((( 1669 1669 **AT+NJM=0** 1630 +))) 1631 + 1632 +(% class="box infomessage" %) 1633 +((( 1670 1670 **ATZ** 1671 1671 ))) 1672 1672 ... ... @@ -1808,6 +1808,8 @@ 1808 1808 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1809 1809 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1810 1810 1775 + 1776 + 1811 1811 = 9. Packing Info = 1812 1812 1813 1813 (((