Last modified by Xiaoling on 2025/04/23 15:57

From version 44.10
edited by Xiaoling
on 2022/06/14 10:05
Change comment: There is no comment for this version
To version 42.1
edited by Xiaoling
on 2022/06/06 11:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,9 +1,13 @@
1 1  (% style="text-align:center" %)
2 -[[image:1652947681187-144.png||height="404" width="404"]]
2 +[[image:1652947681187-144.png||height="385" width="385"]]
3 3  
4 4  
5 5  
6 6  
7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual**
8 +
9 +
10 +
7 7  **Table of Contents:**
8 8  
9 9  {{toc/}}
... ... @@ -63,7 +63,6 @@
63 63  ** Idle: 6uA@3.3v
64 64  ** 20dB Transmit: 130mA@3.3v
65 65  
66 -
67 67  **Interface for Model:**
68 68  
69 69  * 1 x RS485 Interface
... ... @@ -73,7 +73,6 @@
73 73  * 1 x Interrupt Interface
74 74  * 1 x Controllable 5V output, max
75 75  
76 -
77 77  **LoRa Spec:**
78 78  
79 79  * Frequency Range:
... ... @@ -92,9 +92,6 @@
92 92  * 127 dB Dynamic Range RSSI.
93 93  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
94 94  
95 -
96 -
97 -
98 98  == 1.3 Features ==
99 99  
100 100  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -106,9 +106,6 @@
106 106  * Support Modbus protocol
107 107  * Support Interrupt uplink
108 108  
109 -
110 -
111 -
112 112  == 1.4 Applications ==
113 113  
114 114  * Smart Buildings & Home Automation
... ... @@ -118,9 +118,6 @@
118 118  * Smart Cities
119 119  * Smart Factory
120 120  
121 -
122 -
123 -
124 124  == 1.5 Firmware Change log ==
125 125  
126 126  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -204,7 +204,6 @@
204 204  
205 205  [[image:1652953414711-647.png||height="337" width="723"]]
206 206  
207 -
208 208  (((
209 209  The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method.
210 210  )))
... ... @@ -223,13 +223,12 @@
223 223  
224 224  [[image:1652953462722-299.png]]
225 225  
226 -
227 227  (((
228 228  User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot:
229 229  )))
230 230  
231 231  (((
232 -**Add APP EUI in the application.**
223 +Add APP EUI in the application.
233 233  )))
234 234  
235 235  
... ... @@ -241,18 +241,15 @@
241 241  
242 242  [[image:image-20220519174512-4.png]]
243 243  
244 -
245 245  You can also choose to create the device manually.
246 246  
247 247  [[image:1652953542269-423.png||height="710" width="723"]]
248 248  
249 -
250 250  Add APP KEY and DEV EUI
251 251  
252 252  [[image:1652953553383-907.png||height="514" width="724"]]
253 253  
254 254  
255 -
256 256  (((
257 257  **Step 2**: Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel.
258 258  )))
... ... @@ -295,28 +295,28 @@
295 295  )))
296 296  
297 297  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
298 -|=(% style="width: 80px;" %)(((
286 +|=(% style="width: 120px;" %)(((
299 299  (((
300 300  **AT Commands**
301 301  )))
302 -)))|=(% style="width: 210px;" %)(((
290 +)))|=(% style="width: 190px;" %)(((
303 303  (((
304 304  **Description**
305 305  )))
306 -)))|=(% style="width: 210px;" %)(((
294 +)))|=(% style="width: 190px;" %)(((
307 307  (((
308 308  **Example**
309 309  )))
310 310  )))
311 -|(% style="width:80px" %)(((
299 +|(% style="width:120px" %)(((
312 312  (((
313 313  AT+BAUDR
314 314  )))
315 -)))|(% style="width:210px" %)(((
303 +)))|(% style="width:190px" %)(((
316 316  (((
317 317  Set the baud rate (for RS485 connection). Default Value is: 9600.
318 318  )))
319 -)))|(% style="width:210px" %)(((
307 +)))|(% style="width:190px" %)(((
320 320  (((
321 321  (((
322 322  AT+BAUDR=9600
... ... @@ -329,11 +329,11 @@
329 329  )))
330 330  )))
331 331  )))
332 -|(% style="width:80px" %)(((
320 +|(% style="width:120px" %)(((
333 333  (((
334 334  AT+PARITY
335 335  )))
336 -)))|(% style="width:210px" %)(((
324 +)))|(% style="width:190px" %)(((
337 337  (((
338 338  (((
339 339  Set UART parity (for RS485 connection)
... ... @@ -345,7 +345,7 @@
345 345  Default Value is: no parity.
346 346  )))
347 347  )))
348 -)))|(% style="width:210px" %)(((
336 +)))|(% style="width:190px" %)(((
349 349  (((
350 350  (((
351 351  AT+PARITY=0
... ... @@ -358,11 +358,11 @@
358 358  )))
359 359  )))
360 360  )))
361 -|(% style="width:80px" %)(((
349 +|(% style="width:120px" %)(((
362 362  (((
363 363  AT+STOPBIT
364 364  )))
365 -)))|(% style="width:210px" %)(((
353 +)))|(% style="width:190px" %)(((
366 366  (((
367 367  (((
368 368  Set serial stopbit (for RS485 connection)
... ... @@ -374,7 +374,7 @@
374 374  Default Value is: 1bit.
375 375  )))
376 376  )))
377 -)))|(% style="width:210px" %)(((
365 +)))|(% style="width:190px" %)(((
378 378  (((
379 379  (((
380 380  AT+STOPBIT=0 for 1bit
... ... @@ -394,6 +394,8 @@
394 394  )))
395 395  )))
396 396  
385 +
386 +
397 397  === 3.3.2 Configure sensors ===
398 398  
399 399  (((
... ... @@ -405,20 +405,14 @@
405 405  )))
406 406  
407 407  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
408 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
409 -|AT+CFGDEV|(% style="width:80px" %)(((
410 -(((
398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
399 +|AT+CFGDEV|(% style="width:120px" %)(((
411 411  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
412 -)))
413 413  
414 -(((
415 415  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
416 -)))
417 417  
418 -(((
419 419  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
420 -)))
421 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
422 422  
423 423  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
424 424  
... ... @@ -888,7 +888,7 @@
888 888  )))
889 889  
890 890  (((
891 -**}**
875 +{{{}}}}
892 892  
893 893  
894 894  )))
... ... @@ -918,6 +918,8 @@
918 918  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
919 919  )))
920 920  
905 +
906 +
921 921  === 3.5.1 Common Commands: ===
922 922  
923 923  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1441,16 +1441,34 @@
1441 1441  (((
1442 1442  (((
1443 1443  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1430 +)))
1431 +)))
1444 1444  
1433 +(((
1445 1445  Set UART Parity
1435 +)))
1436 +
1437 +(% class="box infomessage" %)
1438 +(((
1439 +(((
1446 1446  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1441 +)))
1442 +)))
1447 1447  
1444 +(((
1448 1448  Set STOPBIT
1446 +)))
1449 1449  
1448 +(% class="box infomessage" %)
1449 +(((
1450 +(((
1450 1450  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1451 1451  )))
1452 1452  )))
1453 1453  
1455 +(((
1456 +
1457 +)))
1454 1454  
1455 1455  * (((
1456 1456  **Downlink Payload:**
... ... @@ -1528,6 +1528,8 @@
1528 1528  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1529 1529  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1530 1530  
1535 +
1536 +
1531 1531  == 3.7 +3V3 Output ==
1532 1532  
1533 1533  (((
... ... @@ -1605,14 +1605,22 @@
1605 1605  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1606 1606  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1607 1607  
1614 +
1615 +
1608 1608  == 3.10 Switch Jumper ==
1609 1609  
1610 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %)
1611 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature**
1612 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART
1618 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
1619 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature**
1620 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)(((
1621 +ISP position: Upgrade firmware via UART
1622 +
1613 1613  Flash position: Configure device, check running status.
1614 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O.
1624 +)))
1625 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)(((
1626 +5V position: set to compatible with 5v I/O.
1627 +
1615 1615  3.3v position: set to compatible with 3.3v I/O.,
1629 +)))
1616 1616  
1617 1617  (((
1618 1618  **+3.3V**: is always ON
... ... @@ -1660,7 +1660,15 @@
1660 1660  (% class="box infomessage" %)
1661 1661  (((
1662 1662  **AT+FDR**
1677 +)))
1678 +
1679 +(% class="box infomessage" %)
1680 +(((
1663 1663  **AT+NJM=0**
1682 +)))
1683 +
1684 +(% class="box infomessage" %)
1685 +(((
1664 1664  **ATZ**
1665 1665  )))
1666 1666  
... ... @@ -1802,6 +1802,8 @@
1802 1802  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1803 1803  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1804 1804  
1827 +
1828 +
1805 1805  = 9. Packing Info =
1806 1806  