Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1652947681187-144.png||height=" 404" width="404"]]2 +[[image:1652947681187-144.png||height="385" width="385"]] 3 3 4 4 5 5 6 6 7 +**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 + 9 + 10 + 7 7 **Table of Contents:** 8 8 9 9 {{toc/}} ... ... @@ -63,7 +63,6 @@ 63 63 ** Idle: 6uA@3.3v 64 64 ** 20dB Transmit: 130mA@3.3v 65 65 66 - 67 67 **Interface for Model:** 68 68 69 69 * 1 x RS485 Interface ... ... @@ -73,7 +73,6 @@ 73 73 * 1 x Interrupt Interface 74 74 * 1 x Controllable 5V output, max 75 75 76 - 77 77 **LoRa Spec:** 78 78 79 79 * Frequency Range: ... ... @@ -92,9 +92,6 @@ 92 92 * 127 dB Dynamic Range RSSI. 93 93 * Automatic RF Sense and CAD with ultra-fast AFC. 94 94 95 - 96 - 97 - 98 98 == 1.3 Features == 99 99 100 100 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -106,9 +106,6 @@ 106 106 * Support Modbus protocol 107 107 * Support Interrupt uplink 108 108 109 - 110 - 111 - 112 112 == 1.4 Applications == 113 113 114 114 * Smart Buildings & Home Automation ... ... @@ -118,9 +118,6 @@ 118 118 * Smart Cities 119 119 * Smart Factory 120 120 121 - 122 - 123 - 124 124 == 1.5 Firmware Change log == 125 125 126 126 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -204,7 +204,6 @@ 204 204 205 205 [[image:1652953414711-647.png||height="337" width="723"]] 206 206 207 - 208 208 ((( 209 209 The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. 210 210 ))) ... ... @@ -223,13 +223,12 @@ 223 223 224 224 [[image:1652953462722-299.png]] 225 225 226 - 227 227 ((( 228 228 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: 229 229 ))) 230 230 231 231 ((( 232 - **Add APP EUI in the application.**223 +Add APP EUI in the application. 233 233 ))) 234 234 235 235 ... ... @@ -241,18 +241,15 @@ 241 241 242 242 [[image:image-20220519174512-4.png]] 243 243 244 - 245 245 You can also choose to create the device manually. 246 246 247 247 [[image:1652953542269-423.png||height="710" width="723"]] 248 248 249 - 250 250 Add APP KEY and DEV EUI 251 251 252 252 [[image:1652953553383-907.png||height="514" width="724"]] 253 253 254 254 255 - 256 256 ((( 257 257 **Step 2**: Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 258 258 ))) ... ... @@ -295,28 +295,28 @@ 295 295 ))) 296 296 297 297 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 298 -|=(% style="width: 80px;" %)(((286 +|=(% style="width: 120px;" %)((( 299 299 ((( 300 300 **AT Commands** 301 301 ))) 302 -)))|=(% style="width: 210px;" %)(((290 +)))|=(% style="width: 190px;" %)((( 303 303 ((( 304 304 **Description** 305 305 ))) 306 -)))|=(% style="width: 210px;" %)(((294 +)))|=(% style="width: 190px;" %)((( 307 307 ((( 308 308 **Example** 309 309 ))) 310 310 ))) 311 -|(% style="width: 80px" %)(((299 +|(% style="width:120px" %)((( 312 312 ((( 313 313 AT+BAUDR 314 314 ))) 315 -)))|(% style="width: 210px" %)(((303 +)))|(% style="width:190px" %)((( 316 316 ((( 317 317 Set the baud rate (for RS485 connection). Default Value is: 9600. 318 318 ))) 319 -)))|(% style="width: 210px" %)(((307 +)))|(% style="width:190px" %)((( 320 320 ((( 321 321 ((( 322 322 AT+BAUDR=9600 ... ... @@ -329,11 +329,11 @@ 329 329 ))) 330 330 ))) 331 331 ))) 332 -|(% style="width: 80px" %)(((320 +|(% style="width:120px" %)((( 333 333 ((( 334 334 AT+PARITY 335 335 ))) 336 -)))|(% style="width: 210px" %)(((324 +)))|(% style="width:190px" %)((( 337 337 ((( 338 338 ((( 339 339 Set UART parity (for RS485 connection) ... ... @@ -345,7 +345,7 @@ 345 345 Default Value is: no parity. 346 346 ))) 347 347 ))) 348 -)))|(% style="width: 210px" %)(((336 +)))|(% style="width:190px" %)((( 349 349 ((( 350 350 ((( 351 351 AT+PARITY=0 ... ... @@ -358,11 +358,11 @@ 358 358 ))) 359 359 ))) 360 360 ))) 361 -|(% style="width: 80px" %)(((349 +|(% style="width:120px" %)((( 362 362 ((( 363 363 AT+STOPBIT 364 364 ))) 365 -)))|(% style="width: 210px" %)(((353 +)))|(% style="width:190px" %)((( 366 366 ((( 367 367 ((( 368 368 Set serial stopbit (for RS485 connection) ... ... @@ -374,7 +374,7 @@ 374 374 Default Value is: 1bit. 375 375 ))) 376 376 ))) 377 -)))|(% style="width: 210px" %)(((365 +)))|(% style="width:190px" %)((( 378 378 ((( 379 379 ((( 380 380 AT+STOPBIT=0 for 1bit ... ... @@ -394,6 +394,8 @@ 394 394 ))) 395 395 ))) 396 396 385 + 386 + 397 397 === 3.3.2 Configure sensors === 398 398 399 399 ((( ... ... @@ -405,20 +405,14 @@ 405 405 ))) 406 406 407 407 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 408 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 409 -|AT+CFGDEV|(% style="width:80px" %)((( 410 -((( 398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 +|AT+CFGDEV|(% style="width:120px" %)((( 411 411 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 412 -))) 413 413 414 -((( 415 415 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 416 -))) 417 417 418 -((( 419 419 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 420 -))) 421 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 422 422 423 423 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 424 424 ... ... @@ -918,6 +918,8 @@ 918 918 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 919 919 ))) 920 920 905 + 906 + 921 921 === 3.5.1 Common Commands: === 922 922 923 923 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -953,101 +953,53 @@ 953 953 954 954 ==== **RS485 Debug Command (AT+CFGDEV)** ==== 955 955 956 -((( 957 957 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 958 -))) 959 959 960 -* ((( 961 -**AT Command** 962 -))) 944 +* **AT Command** 963 963 964 964 (% class="box infomessage" %) 965 965 ((( 966 -((( 967 967 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 968 968 ))) 969 -))) 970 970 971 -((( 972 972 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 973 -))) 974 974 975 -((( 976 - 977 -))) 978 978 979 -* ((( 980 -**Downlink Payload** 981 -))) 954 +* **Downlink Payload** 982 982 983 -((( 984 984 Format: A8 MM NN XX XX XX XX YY 985 -))) 986 986 987 -((( 988 988 Where: 989 -))) 990 990 991 -* ((( 992 -MM: 1: add CRC-16/MODBUS ; 0: no CRC 993 -))) 994 -* ((( 995 -NN: The length of RS485 command 996 -))) 997 -* ((( 998 -XX XX XX XX: RS485 command total NN bytes 999 -))) 1000 -* ((( 1001 -YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 1002 -))) 960 +* MM: 1: add CRC-16/MODBUS ; 0: no CRC 961 +* NN: The length of RS485 command 962 +* XX XX XX XX: RS485 command total NN bytes 963 +* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 1003 1003 1004 -((( 1005 1005 **Example 1:** 1006 -))) 1007 1007 1008 -((( 1009 1009 To connect a Modbus Alarm with below commands. 1010 -))) 1011 1011 1012 -* ((( 1013 -The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1014 -))) 969 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1015 1015 1016 -* ((( 1017 -The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1018 -))) 971 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1019 1019 1020 -((( 1021 1021 So if user want to use downlink command to control to RS485 Alarm, he can use: 1022 -))) 1023 1023 1024 -((( 1025 1025 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 1026 -))) 1027 1027 1028 -((( 1029 1029 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 1030 -))) 1031 1031 1032 1032 ((( 1033 1033 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 1034 1034 ))) 1035 1035 1036 -((( 1037 - 1038 -))) 1039 1039 1040 -((( 1041 1041 **Example 2:** 1042 -))) 1043 1043 1044 -((( 1045 1045 Check TTL Sensor return: 1046 -))) 1047 1047 1048 -((( 1049 1049 [[image:1654132684752-193.png]] 1050 -))) 1051 1051 1052 1052 1053 1053 ... ... @@ -1076,121 +1076,62 @@ 1076 1076 1077 1077 ==== **Set RS485 Sampling Commands** ==== 1078 1078 1079 -((( 1080 1080 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 1081 -))) 1082 1082 1083 -((( 1084 1084 These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 1085 -))) 1086 1086 1087 -((( 1088 - 1089 -))) 1090 1090 1091 -* ((( 1092 -**AT Command:** 1093 -))) 1022 +* **AT Command:** 1094 1094 1095 1095 (% class="box infomessage" %) 1096 1096 ((( 1097 -((( 1098 1098 **AT+COMMANDx: Configure RS485 read command to sensor.** 1099 1099 ))) 1100 -))) 1101 1101 1102 1102 (% class="box infomessage" %) 1103 1103 ((( 1104 -((( 1105 1105 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 1106 1106 ))) 1107 -))) 1108 1108 1109 1109 (% class="box infomessage" %) 1110 1110 ((( 1111 -((( 1112 1112 **AT+SEARCHx: Configure search command** 1113 1113 ))) 1114 -))) 1115 1115 1116 -((( 1117 - 1118 -))) 1119 1119 1120 -* ((( 1121 -**Downlink Payload:** 1122 -))) 1040 +* **Downlink Payload:** 1123 1123 1124 -((( 1125 1125 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 1126 -))) 1127 1127 1128 -((( 1129 1129 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 1130 -))) 1131 1131 1132 -((( 1133 1133 Format: AF MM NN LL XX XX XX XX YY 1134 -))) 1135 1135 1136 -((( 1137 1137 Where: 1138 -))) 1139 1139 1140 -* ((( 1141 -MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 1142 -))) 1143 -* ((( 1144 -NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 1145 -))) 1146 -* ((( 1147 -LL: The length of AT+COMMAND or AT+DATACUT command 1148 -))) 1149 -* ((( 1150 -XX XX XX XX: AT+COMMAND or AT+DATACUT command 1151 -))) 1152 -* ((( 1153 -YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 1154 -))) 1050 +* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 1051 +* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 1052 +* LL: The length of AT+COMMAND or AT+DATACUT command 1053 +* XX XX XX XX: AT+COMMAND or AT+DATACUT command 1054 +* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 1155 1155 1156 -((( 1157 1157 **Example:** 1158 -))) 1159 1159 1160 -((( 1161 1161 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 1162 -))) 1163 1163 1164 -((( 1165 1165 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 1166 -))) 1167 1167 1168 -((( 1169 1169 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 1170 -))) 1171 1171 1172 -((( 1173 - 1174 -))) 1175 1175 1176 -((( 1177 1177 **0xAB** downlink command can be used for set AT+SEARCHx 1178 -))) 1179 1179 1180 -((( 1181 1181 **Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 1182 -))) 1183 1183 1184 -* ((( 1185 -AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 1186 -))) 1187 -* ((( 1188 -AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 1189 -))) 1069 +* AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 1070 +* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 1190 1190 1191 -((( 1192 1192 **AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 1193 -))) 1194 1194 1195 1195 1196 1196 ... ... @@ -1197,47 +1197,24 @@ 1197 1197 1198 1198 ==== **Fast command to handle MODBUS device** ==== 1199 1199 1200 -((( 1201 1201 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 1202 -))) 1203 1203 1204 -((( 1205 1205 This command is valid since v1.3 firmware version 1206 -))) 1207 1207 1208 -((( 1209 - 1210 -))) 1211 1211 1212 -((( 1213 1213 **AT+MBFUN has only two value:** 1214 -))) 1215 1215 1216 -* ((( 1217 -**AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 1218 -))) 1086 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 1219 1219 1220 -((( 1221 1221 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 1222 -))) 1223 1223 1224 -* ((( 1225 -**AT+MBFUN=0**: Disable Modbus fast reading. 1226 -))) 1090 +* **AT+MBFUN=0**: Disable Modbus fast reading. 1227 1227 1228 -((( 1229 1229 **Example:** 1230 -))) 1231 1231 1232 -* ((( 1233 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 1234 -))) 1235 -* ((( 1236 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 1237 -))) 1238 -* ((( 1239 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 1240 -))) 1094 +* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 1095 +* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 1096 +* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 1241 1241 1242 1242 [[image:1654133913295-597.png]] 1243 1243 ... ... @@ -1245,13 +1245,9 @@ 1245 1245 [[image:1654133954153-643.png]] 1246 1246 1247 1247 1248 -* ((( 1249 -**Downlink Commands:** 1250 -))) 1104 +* **Downlink Commands:** 1251 1251 1252 -((( 1253 1253 **A9 aa** ~-~-> Same as AT+MBFUN=aa 1254 -))) 1255 1255 1256 1256 1257 1257 ... ... @@ -1258,60 +1258,32 @@ 1258 1258 1259 1259 ==== **RS485 command timeout** ==== 1260 1260 1261 -((( 1262 1262 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 1263 -))) 1264 1264 1265 -((( 1266 1266 Default value: 0, range: 0 ~~ 5 seconds 1267 -))) 1268 1268 1269 -((( 1270 - 1271 -))) 1272 1272 1273 -* ((( 1274 -**AT Command:** 1275 -))) 1118 +* **AT Command:** 1276 1276 1277 1277 (% class="box infomessage" %) 1278 1278 ((( 1279 -((( 1280 1280 **AT+CMDDLaa=hex(bb cc)** 1281 1281 ))) 1282 -))) 1283 1283 1284 -((( 1285 1285 **Example:** 1286 -))) 1287 1287 1288 -((( 1289 1289 **AT+CMDDL1=1000** to send the open time to 1000ms 1290 -))) 1291 1291 1292 -((( 1293 - 1294 -))) 1295 1295 1296 -* ((( 1297 -**Downlink Payload:** 1298 -))) 1130 +* **Downlink Payload:** 1299 1299 1300 -((( 1301 1301 0x AA aa bb cc 1302 -))) 1303 1303 1304 -((( 1305 1305 Same as: AT+CMDDLaa=hex(bb cc) 1306 -))) 1307 1307 1308 -((( 1309 1309 **Example:** 1310 -))) 1311 1311 1312 -((( 1313 1313 **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 1314 -))) 1315 1315 1316 1316 1317 1317 ... ... @@ -1318,47 +1318,28 @@ 1318 1318 1319 1319 ==== **Uplink payload mode** ==== 1320 1320 1321 -((( 1322 1322 Define to use one uplink or multiple uplinks for the sampling. 1323 -))) 1324 1324 1325 -((( 1326 1326 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 1327 -))) 1328 1328 1329 -* ((( 1330 -**AT Command:** 1331 -))) 1149 +* **AT Command:** 1332 1332 1333 1333 (% class="box infomessage" %) 1334 1334 ((( 1335 -((( 1336 1336 **AT+DATAUP=0** 1337 1337 ))) 1338 -))) 1339 1339 1340 1340 (% class="box infomessage" %) 1341 1341 ((( 1342 -((( 1343 1343 **AT+DATAUP=1** 1344 1344 ))) 1345 -))) 1346 1346 1347 -((( 1348 - 1349 -))) 1350 1350 1351 -* ((( 1352 -**Downlink Payload:** 1353 -))) 1162 +* **Downlink Payload:** 1354 1354 1355 -((( 1356 1356 **0xAD 00** **~-~->** Same as AT+DATAUP=0 1357 -))) 1358 1358 1359 -((( 1360 1360 **0xAD 01** **~-~->** Same as AT+DATAUP=1 1361 -))) 1362 1362 1363 1363 1364 1364 ... ... @@ -1376,49 +1376,26 @@ 1376 1376 1377 1377 ==== **Clear RS485 Command** ==== 1378 1378 1379 -((( 1380 1380 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1381 -))) 1382 1382 1383 -((( 1384 - 1385 -))) 1386 1386 1387 -* ((( 1388 -**AT Command:** 1389 -))) 1187 +* **AT Command:** 1390 1390 1391 1391 ((( 1392 1392 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1393 1393 ))) 1394 1394 1395 -((( 1396 1396 Example screen shot after clear all RS485 commands. 1397 -))) 1398 1398 1399 -((( 1400 - 1401 -))) 1402 1402 1403 -((( 1404 1404 The uplink screen shot is: 1405 -))) 1406 1406 1407 -((( 1408 1408 [[image:1654134704555-320.png]] 1409 -))) 1410 1410 1411 -((( 1412 - 1413 -))) 1414 1414 1415 -* ((( 1416 -**Downlink Payload:** 1417 -))) 1201 +* **Downlink Payload:** 1418 1418 1419 -((( 1420 1420 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1421 -))) 1422 1422 1423 1423 1424 1424 ... ... @@ -1425,59 +1425,44 @@ 1425 1425 1426 1426 ==== **Set Serial Communication Parameters** ==== 1427 1427 1428 -((( 1429 1429 Set the Rs485 serial communication parameters: 1430 -))) 1431 1431 1432 -* ((( 1433 -**AT Command:** 1434 -))) 1212 +* **AT Command:** 1435 1435 1436 -((( 1437 1437 Set Baud Rate: 1438 -))) 1439 1439 1440 1440 (% class="box infomessage" %) 1441 1441 ((( 1442 -((( 1443 1443 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1219 +))) 1444 1444 1445 1445 Set UART Parity 1222 + 1223 +(% class="box infomessage" %) 1224 +((( 1446 1446 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1226 +))) 1447 1447 1448 1448 Set STOPBIT 1449 1449 1230 +(% class="box infomessage" %) 1231 +((( 1450 1450 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1451 1451 ))) 1452 -))) 1453 1453 1454 1454 1455 -* ((( 1456 -**Downlink Payload:** 1457 -))) 1236 +* **Downlink Payload:** 1458 1458 1459 -((( 1460 1460 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1461 -))) 1462 1462 1463 -((( 1464 1464 **Example:** 1465 -))) 1466 1466 1467 -* ((( 1468 -A7 01 00 60 same as AT+BAUDR=9600 1469 -))) 1470 -* ((( 1471 -A7 01 04 80 same as AT+BAUDR=115200 1472 -))) 1242 +* A7 01 00 60 same as AT+BAUDR=9600 1243 +* A7 01 04 80 same as AT+BAUDR=115200 1473 1473 1474 -((( 1475 1475 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1476 -))) 1477 1477 1478 -((( 1479 1479 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1480 -))) 1481 1481 1482 1482 1483 1483 ... ... @@ -1484,41 +1484,22 @@ 1484 1484 1485 1485 ==== **Control output power duration** ==== 1486 1486 1487 -((( 1488 1488 User can set the output power duration before each sampling. 1489 -))) 1490 1490 1491 -* ((( 1492 -**AT Command:** 1493 -))) 1256 +* **AT Command:** 1494 1494 1495 -((( 1496 1496 **Example:** 1497 -))) 1498 1498 1499 -((( 1500 1500 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1501 -))) 1502 1502 1503 -((( 1504 1504 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1505 -))) 1506 1506 1507 -((( 1508 - 1509 -))) 1510 1510 1511 -* ((( 1512 -**LoRaWAN Downlink Command:** 1513 -))) 1265 +* **LoRaWAN Downlink Command:** 1514 1514 1515 -((( 1516 1516 **07 01 aa bb** Same as AT+5VT=(aa bb) 1517 -))) 1518 1518 1519 -((( 1520 1520 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1521 -))) 1522 1522 1523 1523 1524 1524 ... ... @@ -1528,6 +1528,8 @@ 1528 1528 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1529 1529 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1530 1530 1279 + 1280 + 1531 1531 == 3.7 +3V3 Output == 1532 1532 1533 1533 ((( ... ... @@ -1605,14 +1605,22 @@ 1605 1605 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1606 1606 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1607 1607 1358 + 1359 + 1608 1608 == 3.10 Switch Jumper == 1609 1609 1610 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1611 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1612 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1362 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1363 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1364 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1365 +ISP position: Upgrade firmware via UART 1366 + 1613 1613 Flash position: Configure device, check running status. 1614 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1368 +))) 1369 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1370 +5V position: set to compatible with 5v I/O. 1371 + 1615 1615 3.3v position: set to compatible with 3.3v I/O., 1373 +))) 1616 1616 1617 1617 ((( 1618 1618 **+3.3V**: is always ON ... ... @@ -1660,7 +1660,15 @@ 1660 1660 (% class="box infomessage" %) 1661 1661 ((( 1662 1662 **AT+FDR** 1421 +))) 1422 + 1423 +(% class="box infomessage" %) 1424 +((( 1663 1663 **AT+NJM=0** 1426 +))) 1427 + 1428 +(% class="box infomessage" %) 1429 +((( 1664 1664 **ATZ** 1665 1665 ))) 1666 1666 ... ... @@ -1720,23 +1720,13 @@ 1720 1720 1721 1721 == 6.1 How to upgrade the image? == 1722 1722 1723 -((( 1724 1724 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1725 -))) 1726 1726 1727 -* ((( 1728 -Support new features 1729 -))) 1730 -* ((( 1731 -For bug fix 1732 -))) 1733 -* ((( 1734 -Change LoRaWAN bands. 1735 -))) 1491 +* Support new features 1492 +* For bug fix 1493 +* Change LoRaWAN bands. 1736 1736 1737 -((( 1738 1738 Below shows the hardware connection for how to upload an image to RS485-BL: 1739 -))) 1740 1740 1741 1741 [[image:1654136646995-976.png]] 1742 1742