Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
From version 44.1
edited by Edwin Chen
on 2022/06/13 10:49
on 2022/06/13 10:49
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -395,17 +395,11 @@ 395 395 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 396 396 |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 397 397 |AT+CFGDEV|(% style="width:80px" %)((( 398 -((( 399 399 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 400 -))) 401 401 402 -((( 403 403 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 404 -))) 405 405 406 -((( 407 407 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 408 -))) 409 409 )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 410 410 411 411 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. ... ... @@ -876,7 +876,7 @@ 876 876 ))) 877 877 878 878 ((( 879 - **}**873 +} 880 880 881 881 882 882 ))) ... ... @@ -1429,16 +1429,34 @@ 1429 1429 ((( 1430 1430 ((( 1431 1431 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1426 +))) 1427 +))) 1432 1432 1429 +((( 1433 1433 Set UART Parity 1431 +))) 1432 + 1433 +(% class="box infomessage" %) 1434 +((( 1435 +((( 1434 1434 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1437 +))) 1438 +))) 1435 1435 1440 +((( 1436 1436 Set STOPBIT 1442 +))) 1437 1437 1444 +(% class="box infomessage" %) 1445 +((( 1446 +((( 1438 1438 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1439 1439 ))) 1440 1440 ))) 1441 1441 1451 +((( 1452 + 1453 +))) 1442 1442 1443 1443 * ((( 1444 1444 **Downlink Payload:** ... ... @@ -1516,6 +1516,7 @@ 1516 1516 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1517 1517 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1518 1518 1531 + 1519 1519 == 3.7 +3V3 Output == 1520 1520 1521 1521 ((( ... ... @@ -1593,14 +1593,22 @@ 1593 1593 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1594 1594 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1595 1595 1609 + 1610 + 1596 1596 == 3.10 Switch Jumper == 1597 1597 1598 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1599 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1600 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1613 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1614 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1615 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1616 +ISP position: Upgrade firmware via UART 1617 + 1601 1601 Flash position: Configure device, check running status. 1602 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1619 +))) 1620 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1621 +5V position: set to compatible with 5v I/O. 1622 + 1603 1603 3.3v position: set to compatible with 3.3v I/O., 1624 +))) 1604 1604 1605 1605 ((( 1606 1606 **+3.3V**: is always ON ... ... @@ -1648,7 +1648,15 @@ 1648 1648 (% class="box infomessage" %) 1649 1649 ((( 1650 1650 **AT+FDR** 1672 +))) 1673 + 1674 +(% class="box infomessage" %) 1675 +((( 1651 1651 **AT+NJM=0** 1677 +))) 1678 + 1679 +(% class="box infomessage" %) 1680 +((( 1652 1652 **ATZ** 1653 1653 ))) 1654 1654