Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
From version 42.5
edited by Xiaoling
on 2022/06/06 13:41
on 2022/06/06 13:41
Change comment:
There is no comment for this version
To version 43.1
edited by Edwin Chen
on 2022/06/13 10:47
on 2022/06/13 10:47
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -94,6 +94,7 @@ 94 94 * 127 dB Dynamic Range RSSI. 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 97 + 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -105,6 +105,7 @@ 105 105 * Support Modbus protocol 106 106 * Support Interrupt uplink 107 107 109 + 108 108 == 1.4 Applications == 109 109 110 110 * Smart Buildings & Home Automation ... ... @@ -114,6 +114,7 @@ 114 114 * Smart Cities 115 115 * Smart Factory 116 116 119 + 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -382,6 +382,7 @@ 382 382 ))) 383 383 ))) 384 384 388 + 385 385 === 3.3.2 Configure sensors === 386 386 387 387 ((( ... ... @@ -395,11 +395,17 @@ 395 395 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 396 396 |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 397 397 |AT+CFGDEV|(% style="width:80px" %)((( 402 +((( 398 398 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 404 +))) 399 399 406 +((( 400 400 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 408 +))) 401 401 410 +((( 402 402 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 412 +))) 403 403 )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 404 404 405 405 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. ... ... @@ -870,7 +870,7 @@ 870 870 ))) 871 871 872 872 ((( 873 -} 883 +**}** 874 874 875 875 876 876 ))) ... ... @@ -1423,34 +1423,16 @@ 1423 1423 ((( 1424 1424 ((( 1425 1425 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1426 -))) 1427 -))) 1428 1428 1429 -((( 1430 1430 Set UART Parity 1431 -))) 1432 - 1433 -(% class="box infomessage" %) 1434 -((( 1435 -((( 1436 1436 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1437 -))) 1438 -))) 1439 1439 1440 -((( 1441 1441 Set STOPBIT 1442 -))) 1443 1443 1444 -(% class="box infomessage" %) 1445 -((( 1446 -((( 1447 1447 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1448 1448 ))) 1449 1449 ))) 1450 1450 1451 -((( 1452 - 1453 -))) 1454 1454 1455 1455 * ((( 1456 1456 **Downlink Payload:** ... ... @@ -1528,8 +1528,6 @@ 1528 1528 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1529 1529 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1530 1530 1531 - 1532 - 1533 1533 == 3.7 +3V3 Output == 1534 1534 1535 1535 ((( ... ... @@ -1609,18 +1609,12 @@ 1609 1609 1610 1610 == 3.10 Switch Jumper == 1611 1611 1612 -(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1613 -|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1614 -|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1615 -ISP position: Upgrade firmware via UART 1616 - 1602 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1603 +|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1604 +|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1617 1617 Flash position: Configure device, check running status. 1618 -))) 1619 -|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1620 -5V position: set to compatible with 5v I/O. 1621 - 1606 +|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1622 1622 3.3v position: set to compatible with 3.3v I/O., 1623 -))) 1624 1624 1625 1625 ((( 1626 1626 **+3.3V**: is always ON