Last modified by Xiaoling on 2025/04/23 15:57

From version 42.3
edited by Xiaoling
on 2022/06/06 12:01
Change comment: There is no comment for this version
To version 42.24
edited by Xiaoling
on 2022/06/06 14:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -94,6 +94,8 @@
94 94  * 127 dB Dynamic Range RSSI.
95 95  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
96 96  
97 +
98 +
97 97  == 1.3 Features ==
98 98  
99 99  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -105,6 +105,8 @@
105 105  * Support Modbus protocol
106 106  * Support Interrupt uplink
107 107  
110 +
111 +
108 108  == 1.4 Applications ==
109 109  
110 110  * Smart Buildings & Home Automation
... ... @@ -114,6 +114,8 @@
114 114  * Smart Cities
115 115  * Smart Factory
116 116  
121 +
122 +
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -291,7 +291,7 @@
291 291  (((
292 292  **Description**
293 293  )))
294 -)))|=(% style="width: 2100px;" %)(((
300 +)))|=(% style="width: 210px;" %)(((
295 295  (((
296 296  **Example**
297 297  )))
... ... @@ -382,6 +382,8 @@
382 382  )))
383 383  )))
384 384  
391 +
392 +
385 385  === 3.3.2 Configure sensors ===
386 386  
387 387  (((
... ... @@ -395,11 +395,17 @@
395 395  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
396 396  |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
397 397  |AT+CFGDEV|(% style="width:80px" %)(((
406 +(((
398 398  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
408 +)))
399 399  
410 +(((
400 400  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
412 +)))
401 401  
414 +(((
402 402  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
416 +)))
403 403  )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
404 404  
405 405  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
... ... @@ -870,7 +870,7 @@
870 870  )))
871 871  
872 872  (((
873 -}
887 +**}**
874 874  
875 875  
876 876  )))
... ... @@ -900,6 +900,7 @@
900 900  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
901 901  )))
902 902  
917 +
903 903  === 3.5.1 Common Commands: ===
904 904  
905 905  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1528,6 +1528,7 @@
1528 1528  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1529 1529  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1530 1530  
1546 +
1531 1531  == 3.7 +3V3 Output ==
1532 1532  
1533 1533  (((
... ... @@ -1605,20 +1605,15 @@
1605 1605  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1606 1606  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1607 1607  
1624 +
1608 1608  == 3.10 Switch Jumper ==
1609 1609  
1610 -(% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
1611 -|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature**
1612 -|(% style="width:124px" %)**SW1**|(% style="width:388px" %)(((
1613 -ISP position: Upgrade firmware via UART
1614 -
1627 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %)
1628 +|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature**
1629 +|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART
1615 1615  Flash position: Configure device, check running status.
1616 -)))
1617 -|(% style="width:124px" %)**SW2**|(% style="width:388px" %)(((
1618 -5V position: set to compatible with 5v I/O.
1619 -
1631 +|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O.
1620 1620  3.3v position: set to compatible with 3.3v I/O.,
1621 -)))
1622 1622  
1623 1623  (((
1624 1624  **+3.3V**: is always ON
... ... @@ -1816,6 +1816,7 @@
1816 1816  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1817 1817  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1818 1818  
1830 +
1819 1819  = 9. Packing Info =
1820 1820  
1821 1821  (((