Last modified by Xiaoling on 2025/04/23 15:57

From version 42.25
edited by Xiaoling
on 2022/06/06 14:30
Change comment: There is no comment for this version
To version 42.6
edited by Xiaoling
on 2022/06/06 13:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -94,8 +94,6 @@
94 94  * 127 dB Dynamic Range RSSI.
95 95  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
96 96  
97 -
98 -
99 99  == 1.3 Features ==
100 100  
101 101  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -107,8 +107,6 @@
107 107  * Support Modbus protocol
108 108  * Support Interrupt uplink
109 109  
110 -
111 -
112 112  == 1.4 Applications ==
113 113  
114 114  * Smart Buildings & Home Automation
... ... @@ -118,8 +118,6 @@
118 118  * Smart Cities
119 119  * Smart Factory
120 120  
121 -
122 -
123 123  == 1.5 Firmware Change log ==
124 124  
125 125  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -388,8 +388,6 @@
388 388  )))
389 389  )))
390 390  
391 -
392 -
393 393  === 3.3.2 Configure sensors ===
394 394  
395 395  (((
... ... @@ -403,17 +403,11 @@
403 403  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
404 404  |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
405 405  |AT+CFGDEV|(% style="width:80px" %)(((
406 -(((
407 407  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
408 -)))
409 409  
410 -(((
411 411  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
412 -)))
413 413  
414 -(((
415 415  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
416 -)))
417 417  )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
418 418  
419 419  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
... ... @@ -884,7 +884,7 @@
884 884  )))
885 885  
886 886  (((
887 -**}**
873 +}
888 888  
889 889  
890 890  )))
... ... @@ -914,7 +914,6 @@
914 914  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
915 915  )))
916 916  
917 -
918 918  === 3.5.1 Common Commands: ===
919 919  
920 920  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1622,14 +1622,21 @@
1622 1622  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1623 1623  
1624 1624  
1610 +
1625 1625  == 3.10 Switch Jumper ==
1626 1626  
1627 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %)
1628 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature**
1629 -|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART
1613 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
1614 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature**
1615 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)(((
1616 +ISP position: Upgrade firmware via UART
1617 +
1630 1630  Flash position: Configure device, check running status.
1631 -|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O.
1619 +)))
1620 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)(((
1621 +5V position: set to compatible with 5v I/O.
1622 +
1632 1632  3.3v position: set to compatible with 3.3v I/O.,
1624 +)))
1633 1633  
1634 1634  (((
1635 1635  **+3.3V**: is always ON
... ... @@ -1827,7 +1827,6 @@
1827 1827  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1828 1828  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1829 1829  
1830 -
1831 1831  = 9. Packing Info =
1832 1832  
1833 1833  (((