Last modified by Xiaoling on 2025/04/23 15:57

From version 42.20
edited by Xiaoling
on 2022/06/06 14:25
Change comment: There is no comment for this version
To version 43.1
edited by Edwin Chen
on 2022/06/13 10:47
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -95,7 +95,6 @@
95 95  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
96 96  
97 97  
98 -
99 99  == 1.3 Features ==
100 100  
101 101  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -108,7 +108,6 @@
108 108  * Support Interrupt uplink
109 109  
110 110  
111 -
112 112  == 1.4 Applications ==
113 113  
114 114  * Smart Buildings & Home Automation
... ... @@ -119,7 +119,6 @@
119 119  * Smart Factory
120 120  
121 121  
122 -
123 123  == 1.5 Firmware Change log ==
124 124  
125 125  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -388,6 +388,7 @@
388 388  )))
389 389  )))
390 390  
388 +
391 391  === 3.3.2 Configure sensors ===
392 392  
393 393  (((
... ... @@ -401,11 +401,17 @@
401 401  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
402 402  |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
403 403  |AT+CFGDEV|(% style="width:80px" %)(((
402 +(((
404 404  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
404 +)))
405 405  
406 +(((
406 406  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
408 +)))
407 407  
410 +(((
408 408  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
412 +)))
409 409  )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
410 410  
411 411  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
... ... @@ -876,7 +876,7 @@
876 876  )))
877 877  
878 878  (((
879 -}
883 +**}**
880 880  
881 881  
882 882  )))
... ... @@ -906,7 +906,6 @@
906 906  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
907 907  )))
908 908  
909 -
910 910  === 3.5.1 Common Commands: ===
911 911  
912 912  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1430,34 +1430,16 @@
1430 1430  (((
1431 1431  (((
1432 1432  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1433 -)))
1434 -)))
1435 1435  
1436 -(((
1437 1437  Set UART Parity
1438 -)))
1439 -
1440 -(% class="box infomessage" %)
1441 -(((
1442 -(((
1443 1443  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1444 -)))
1445 -)))
1446 1446  
1447 -(((
1448 1448  Set STOPBIT
1449 -)))
1450 1450  
1451 -(% class="box infomessage" %)
1452 -(((
1453 -(((
1454 1454  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1455 1455  )))
1456 1456  )))
1457 1457  
1458 -(((
1459 -
1460 -)))
1461 1461  
1462 1462  * (((
1463 1463  **Downlink Payload:**
... ... @@ -1535,7 +1535,6 @@
1535 1535  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1536 1536  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1537 1537  
1538 -
1539 1539  == 3.7 +3V3 Output ==
1540 1540  
1541 1541  (((
... ... @@ -1613,14 +1613,13 @@
1613 1613  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1614 1614  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1615 1615  
1616 -
1617 1617  == 3.10 Switch Jumper ==
1618 1618  
1619 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %)
1620 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 277px;" %)**Feature**
1621 -|(% style="width:123px" %)**SW1**|(% style="width:277px" %)ISP position: Upgrade firmware via UART
1602 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %)
1603 +|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature**
1604 +|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART
1622 1622  Flash position: Configure device, check running status.
1623 -|(% style="width:123px" %)**SW2**|(% style="width:277px" %)5V position: set to compatible with 5v I/O.
1606 +|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O.
1624 1624  3.3v position: set to compatible with 3.3v I/O.,
1625 1625  
1626 1626  (((
... ... @@ -1819,7 +1819,6 @@
1819 1819  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1820 1820  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1821 1821  
1822 -
1823 1823  = 9. Packing Info =
1824 1824  
1825 1825  (((