Last modified by Xiaoling on 2025/04/23 15:57

From version 42.19
edited by Xiaoling
on 2022/06/06 14:25
Change comment: There is no comment for this version
To version 43.1
edited by Edwin Chen
on 2022/06/13 10:47
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -95,7 +95,6 @@
95 95  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
96 96  
97 97  
98 -
99 99  == 1.3 Features ==
100 100  
101 101  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -108,7 +108,6 @@
108 108  * Support Interrupt uplink
109 109  
110 110  
111 -
112 112  == 1.4 Applications ==
113 113  
114 114  * Smart Buildings & Home Automation
... ... @@ -118,6 +118,7 @@
118 118  * Smart Cities
119 119  * Smart Factory
120 120  
119 +
121 121  == 1.5 Firmware Change log ==
122 122  
123 123  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -386,6 +386,7 @@
386 386  )))
387 387  )))
388 388  
388 +
389 389  === 3.3.2 Configure sensors ===
390 390  
391 391  (((
... ... @@ -399,11 +399,17 @@
399 399  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
400 400  |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
401 401  |AT+CFGDEV|(% style="width:80px" %)(((
402 +(((
402 402  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
404 +)))
403 403  
406 +(((
404 404  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
408 +)))
405 405  
410 +(((
406 406  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
412 +)))
407 407  )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
408 408  
409 409  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
... ... @@ -874,7 +874,7 @@
874 874  )))
875 875  
876 876  (((
877 -}
883 +**}**
878 878  
879 879  
880 880  )))
... ... @@ -904,7 +904,6 @@
904 904  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
905 905  )))
906 906  
907 -
908 908  === 3.5.1 Common Commands: ===
909 909  
910 910  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1428,34 +1428,16 @@
1428 1428  (((
1429 1429  (((
1430 1430  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1431 -)))
1432 -)))
1433 1433  
1434 -(((
1435 1435  Set UART Parity
1436 -)))
1437 -
1438 -(% class="box infomessage" %)
1439 -(((
1440 -(((
1441 1441  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1442 -)))
1443 -)))
1444 1444  
1445 -(((
1446 1446  Set STOPBIT
1447 -)))
1448 1448  
1449 -(% class="box infomessage" %)
1450 -(((
1451 -(((
1452 1452  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1453 1453  )))
1454 1454  )))
1455 1455  
1456 -(((
1457 -
1458 -)))
1459 1459  
1460 1460  * (((
1461 1461  **Downlink Payload:**
... ... @@ -1533,7 +1533,6 @@
1533 1533  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1534 1534  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1535 1535  
1536 -
1537 1537  == 3.7 +3V3 Output ==
1538 1538  
1539 1539  (((
... ... @@ -1611,14 +1611,13 @@
1611 1611  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1612 1612  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1613 1613  
1614 -
1615 1615  == 3.10 Switch Jumper ==
1616 1616  
1617 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %)
1618 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 277px;" %)**Feature**
1619 -|(% style="width:123px" %)**SW1**|(% style="width:277px" %)ISP position: Upgrade firmware via UART
1602 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %)
1603 +|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature**
1604 +|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART
1620 1620  Flash position: Configure device, check running status.
1621 -|(% style="width:123px" %)**SW2**|(% style="width:277px" %)5V position: set to compatible with 5v I/O.
1606 +|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O.
1622 1622  3.3v position: set to compatible with 3.3v I/O.,
1623 1623  
1624 1624  (((
... ... @@ -1817,7 +1817,6 @@
1817 1817  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1818 1818  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1819 1819  
1820 -
1821 1821  = 9. Packing Info =
1822 1822  
1823 1823  (((