Last modified by Xiaoling on 2025/04/23 15:57

From version 42.19
edited by Xiaoling
on 2022/06/06 14:25
Change comment: There is no comment for this version
To version 41.39
edited by Xiaoling
on 2022/06/06 11:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -94,8 +94,6 @@
94 94  * 127 dB Dynamic Range RSSI.
95 95  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
96 96  
97 -
98 -
99 99  == 1.3 Features ==
100 100  
101 101  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -107,8 +107,6 @@
107 107  * Support Modbus protocol
108 108  * Support Interrupt uplink
109 109  
110 -
111 -
112 112  == 1.4 Applications ==
113 113  
114 114  * Smart Buildings & Home Automation
... ... @@ -287,28 +287,28 @@
287 287  )))
288 288  
289 289  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
290 -|=(% style="width: 80px;" %)(((
286 +|=(% style="width: 120px;" %)(((
291 291  (((
292 292  **AT Commands**
293 293  )))
294 -)))|=(% style="width: 210px;" %)(((
290 +)))|=(% style="width: 190px;" %)(((
295 295  (((
296 296  **Description**
297 297  )))
298 -)))|=(% style="width: 210px;" %)(((
294 +)))|=(% style="width: 190px;" %)(((
299 299  (((
300 300  **Example**
301 301  )))
302 302  )))
303 -|(% style="width:80px" %)(((
299 +|(% style="width:120px" %)(((
304 304  (((
305 305  AT+BAUDR
306 306  )))
307 -)))|(% style="width:210px" %)(((
303 +)))|(% style="width:190px" %)(((
308 308  (((
309 309  Set the baud rate (for RS485 connection). Default Value is: 9600.
310 310  )))
311 -)))|(% style="width:210px" %)(((
307 +)))|(% style="width:190px" %)(((
312 312  (((
313 313  (((
314 314  AT+BAUDR=9600
... ... @@ -321,11 +321,11 @@
321 321  )))
322 322  )))
323 323  )))
324 -|(% style="width:80px" %)(((
320 +|(% style="width:120px" %)(((
325 325  (((
326 326  AT+PARITY
327 327  )))
328 -)))|(% style="width:210px" %)(((
324 +)))|(% style="width:190px" %)(((
329 329  (((
330 330  (((
331 331  Set UART parity (for RS485 connection)
... ... @@ -337,7 +337,7 @@
337 337  Default Value is: no parity.
338 338  )))
339 339  )))
340 -)))|(% style="width:210px" %)(((
336 +)))|(% style="width:190px" %)(((
341 341  (((
342 342  (((
343 343  AT+PARITY=0
... ... @@ -350,11 +350,11 @@
350 350  )))
351 351  )))
352 352  )))
353 -|(% style="width:80px" %)(((
349 +|(% style="width:120px" %)(((
354 354  (((
355 355  AT+STOPBIT
356 356  )))
357 -)))|(% style="width:210px" %)(((
353 +)))|(% style="width:190px" %)(((
358 358  (((
359 359  (((
360 360  Set serial stopbit (for RS485 connection)
... ... @@ -366,7 +366,7 @@
366 366  Default Value is: 1bit.
367 367  )))
368 368  )))
369 -)))|(% style="width:210px" %)(((
365 +)))|(% style="width:190px" %)(((
370 370  (((
371 371  (((
372 372  AT+STOPBIT=0 for 1bit
... ... @@ -386,6 +386,8 @@
386 386  )))
387 387  )))
388 388  
385 +
386 +
389 389  === 3.3.2 Configure sensors ===
390 390  
391 391  (((
... ... @@ -397,14 +397,14 @@
397 397  )))
398 398  
399 399  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
400 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
401 -|AT+CFGDEV|(% style="width:80px" %)(((
398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
399 +|AT+CFGDEV|(% style="width:120px" %)(((
402 402  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
403 403  
404 404  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
405 405  
406 406  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
407 -)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
408 408  
409 409  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
410 410  
... ... @@ -874,7 +874,7 @@
874 874  )))
875 875  
876 876  (((
877 -}
875 +{{{}}}}
878 878  
879 879  
880 880  )))
... ... @@ -905,6 +905,7 @@
905 905  )))
906 906  
907 907  
906 +
908 908  === 3.5.1 Common Commands: ===
909 909  
910 910  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1412,77 +1412,44 @@
1412 1412  
1413 1413  ==== **Set Serial Communication Parameters** ====
1414 1414  
1415 -(((
1416 1416  Set the Rs485 serial communication parameters:
1417 -)))
1418 1418  
1419 -* (((
1420 -**AT Command:**
1421 -)))
1416 +* **AT Command:**
1422 1422  
1423 -(((
1424 1424  Set Baud Rate:
1425 -)))
1426 1426  
1427 1427  (% class="box infomessage" %)
1428 1428  (((
1429 -(((
1430 1430  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1431 1431  )))
1432 -)))
1433 1433  
1434 -(((
1435 1435  Set UART Parity
1436 -)))
1437 1437  
1438 1438  (% class="box infomessage" %)
1439 1439  (((
1440 -(((
1441 1441  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1442 1442  )))
1443 -)))
1444 1444  
1445 -(((
1446 1446  Set STOPBIT
1447 -)))
1448 1448  
1449 1449  (% class="box infomessage" %)
1450 1450  (((
1451 -(((
1452 1452  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1453 1453  )))
1454 -)))
1455 1455  
1456 -(((
1457 -
1458 -)))
1459 1459  
1460 -* (((
1461 -**Downlink Payload:**
1462 -)))
1440 +* **Downlink Payload:**
1463 1463  
1464 -(((
1465 1465  **A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1466 -)))
1467 1467  
1468 -(((
1469 1469  **Example:**
1470 -)))
1471 1471  
1472 -* (((
1473 -A7 01 00 60   same as AT+BAUDR=9600
1474 -)))
1475 -* (((
1476 -A7 01 04 80  same as AT+BAUDR=115200
1477 -)))
1446 +* A7 01 00 60   same as AT+BAUDR=9600
1447 +* A7 01 04 80  same as AT+BAUDR=115200
1478 1478  
1479 -(((
1480 1480  A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1481 -)))
1482 1482  
1483 -(((
1484 1484  A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1485 -)))
1486 1486  
1487 1487  
1488 1488  
... ... @@ -1489,41 +1489,22 @@
1489 1489  
1490 1490  ==== **Control output power duration** ====
1491 1491  
1492 -(((
1493 1493  User can set the output power duration before each sampling.
1494 -)))
1495 1495  
1496 -* (((
1497 -**AT Command:**
1498 -)))
1460 +* **AT Command:**
1499 1499  
1500 -(((
1501 1501  **Example:**
1502 -)))
1503 1503  
1504 -(((
1505 1505  **AT+3V3T=1000**  ~/~/ 3V3 output power will open 1s before each sampling.
1506 -)))
1507 1507  
1508 -(((
1509 1509  **AT+5VT=1000**  ~/~/ +5V output power will open 1s before each sampling.
1510 -)))
1511 1511  
1512 -(((
1513 -
1514 -)))
1515 1515  
1516 -* (((
1517 -**LoRaWAN Downlink Command:**
1518 -)))
1469 +* **LoRaWAN Downlink Command:**
1519 1519  
1520 -(((
1521 1521  **07 01 aa bb**  Same as AT+5VT=(aa bb)
1522 -)))
1523 1523  
1524 -(((
1525 1525  **07 02 aa bb**  Same as AT+3V3T=(aa bb)
1526 -)))
1527 1527  
1528 1528  
1529 1529  
... ... @@ -1534,6 +1534,7 @@
1534 1534  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1535 1535  
1536 1536  
1484 +
1537 1537  == 3.7 +3V3 Output ==
1538 1538  
1539 1539  (((
... ... @@ -1612,14 +1612,21 @@
1612 1612  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1613 1613  
1614 1614  
1563 +
1615 1615  == 3.10 Switch Jumper ==
1616 1616  
1617 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %)
1618 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 277px;" %)**Feature**
1619 -|(% style="width:123px" %)**SW1**|(% style="width:277px" %)ISP position: Upgrade firmware via UART
1566 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
1567 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature**
1568 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)(((
1569 +ISP position: Upgrade firmware via UART
1570 +
1620 1620  Flash position: Configure device, check running status.
1621 -|(% style="width:123px" %)**SW2**|(% style="width:277px" %)5V position: set to compatible with 5v I/O.
1572 +)))
1573 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)(((
1574 +5V position: set to compatible with 5v I/O.
1575 +
1622 1622  3.3v position: set to compatible with 3.3v I/O.,
1577 +)))
1623 1623  
1624 1624  (((
1625 1625  **+3.3V**: is always ON
... ... @@ -1818,6 +1818,7 @@
1818 1818  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1819 1819  
1820 1820  
1776 +
1821 1821  = 9. Packing Info =
1822 1822  
1823 1823  (((