Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -94,8 +94,6 @@ 94 94 * 127 dB Dynamic Range RSSI. 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 97 - 98 - 99 99 == 1.3 Features == 100 100 101 101 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -285,28 +285,28 @@ 285 285 ))) 286 286 287 287 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 288 -|=(% style="width: 80px;" %)(((286 +|=(% style="width: 120px;" %)((( 289 289 ((( 290 290 **AT Commands** 291 291 ))) 292 -)))|=(% style="width: 210px;" %)(((290 +)))|=(% style="width: 190px;" %)((( 293 293 ((( 294 294 **Description** 295 295 ))) 296 -)))|=(% style="width: 210px;" %)(((294 +)))|=(% style="width: 190px;" %)((( 297 297 ((( 298 298 **Example** 299 299 ))) 300 300 ))) 301 -|(% style="width: 80px" %)(((299 +|(% style="width:120px" %)((( 302 302 ((( 303 303 AT+BAUDR 304 304 ))) 305 -)))|(% style="width: 210px" %)(((303 +)))|(% style="width:190px" %)((( 306 306 ((( 307 307 Set the baud rate (for RS485 connection). Default Value is: 9600. 308 308 ))) 309 -)))|(% style="width: 210px" %)(((307 +)))|(% style="width:190px" %)((( 310 310 ((( 311 311 ((( 312 312 AT+BAUDR=9600 ... ... @@ -319,11 +319,11 @@ 319 319 ))) 320 320 ))) 321 321 ))) 322 -|(% style="width: 80px" %)(((320 +|(% style="width:120px" %)((( 323 323 ((( 324 324 AT+PARITY 325 325 ))) 326 -)))|(% style="width: 210px" %)(((324 +)))|(% style="width:190px" %)((( 327 327 ((( 328 328 ((( 329 329 Set UART parity (for RS485 connection) ... ... @@ -335,7 +335,7 @@ 335 335 Default Value is: no parity. 336 336 ))) 337 337 ))) 338 -)))|(% style="width: 210px" %)(((336 +)))|(% style="width:190px" %)((( 339 339 ((( 340 340 ((( 341 341 AT+PARITY=0 ... ... @@ -348,11 +348,11 @@ 348 348 ))) 349 349 ))) 350 350 ))) 351 -|(% style="width: 80px" %)(((349 +|(% style="width:120px" %)((( 352 352 ((( 353 353 AT+STOPBIT 354 354 ))) 355 -)))|(% style="width: 210px" %)(((353 +)))|(% style="width:190px" %)((( 356 356 ((( 357 357 ((( 358 358 Set serial stopbit (for RS485 connection) ... ... @@ -364,7 +364,7 @@ 364 364 Default Value is: 1bit. 365 365 ))) 366 366 ))) 367 -)))|(% style="width: 210px" %)(((365 +)))|(% style="width:190px" %)((( 368 368 ((( 369 369 ((( 370 370 AT+STOPBIT=0 for 1bit ... ... @@ -384,6 +384,8 @@ 384 384 ))) 385 385 ))) 386 386 385 + 386 + 387 387 === 3.3.2 Configure sensors === 388 388 389 389 ((( ... ... @@ -395,14 +395,14 @@ 395 395 ))) 396 396 397 397 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 398 -|=(% style="width: 80px;" %)**AT Commands**|=(% style="width:210px;" %)**Description**|=(% style="width:210px;" %)**Example**399 -|AT+CFGDEV|(% style="width: 80px" %)(((398 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 +|AT+CFGDEV|(% style="width:120px" %)((( 400 400 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 401 401 402 402 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 403 403 404 404 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 405 -)))|(% style="width: 210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m405 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 406 406 407 407 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 408 408 ... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 -} 875 +{{{}}}} 876 876 877 877 878 878 ))) ... ... @@ -903,6 +903,7 @@ 903 903 ))) 904 904 905 905 906 + 906 906 === 3.5.1 Common Commands: === 907 907 908 908 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1361,49 +1361,26 @@ 1361 1361 1362 1362 ==== **Clear RS485 Command** ==== 1363 1363 1364 -((( 1365 1365 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1366 -))) 1367 1367 1368 -((( 1369 - 1370 -))) 1371 1371 1372 -* ((( 1373 -**AT Command:** 1374 -))) 1368 +* **AT Command:** 1375 1375 1376 1376 ((( 1377 1377 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1378 1378 ))) 1379 1379 1380 -((( 1381 1381 Example screen shot after clear all RS485 commands. 1382 -))) 1383 1383 1384 -((( 1385 - 1386 -))) 1387 1387 1388 -((( 1389 1389 The uplink screen shot is: 1390 -))) 1391 1391 1392 -((( 1393 1393 [[image:1654134704555-320.png]] 1394 -))) 1395 1395 1396 -((( 1397 - 1398 -))) 1399 1399 1400 -* ((( 1401 -**Downlink Payload:** 1402 -))) 1382 +* **Downlink Payload:** 1403 1403 1404 -((( 1405 1405 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1406 -))) 1407 1407 1408 1408 1409 1409 ... ... @@ -1410,77 +1410,44 @@ 1410 1410 1411 1411 ==== **Set Serial Communication Parameters** ==== 1412 1412 1413 -((( 1414 1414 Set the Rs485 serial communication parameters: 1415 -))) 1416 1416 1417 -* ((( 1418 -**AT Command:** 1419 -))) 1393 +* **AT Command:** 1420 1420 1421 -((( 1422 1422 Set Baud Rate: 1423 -))) 1424 1424 1425 1425 (% class="box infomessage" %) 1426 1426 ((( 1427 -((( 1428 1428 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1429 1429 ))) 1430 -))) 1431 1431 1432 -((( 1433 1433 Set UART Parity 1434 -))) 1435 1435 1436 1436 (% class="box infomessage" %) 1437 1437 ((( 1438 -((( 1439 1439 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1440 1440 ))) 1441 -))) 1442 1442 1443 -((( 1444 1444 Set STOPBIT 1445 -))) 1446 1446 1447 1447 (% class="box infomessage" %) 1448 1448 ((( 1449 -((( 1450 1450 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1451 1451 ))) 1452 -))) 1453 1453 1454 -((( 1455 - 1456 -))) 1457 1457 1458 -* ((( 1459 -**Downlink Payload:** 1460 -))) 1417 +* **Downlink Payload:** 1461 1461 1462 -((( 1463 1463 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1464 -))) 1465 1465 1466 -((( 1467 1467 **Example:** 1468 -))) 1469 1469 1470 -* ((( 1471 -A7 01 00 60 same as AT+BAUDR=9600 1472 -))) 1473 -* ((( 1474 -A7 01 04 80 same as AT+BAUDR=115200 1475 -))) 1423 +* A7 01 00 60 same as AT+BAUDR=9600 1424 +* A7 01 04 80 same as AT+BAUDR=115200 1476 1476 1477 -((( 1478 1478 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1479 -))) 1480 1480 1481 -((( 1482 1482 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1483 -))) 1484 1484 1485 1485 1486 1486 ... ... @@ -1487,41 +1487,22 @@ 1487 1487 1488 1488 ==== **Control output power duration** ==== 1489 1489 1490 -((( 1491 1491 User can set the output power duration before each sampling. 1492 -))) 1493 1493 1494 -* ((( 1495 -**AT Command:** 1496 -))) 1437 +* **AT Command:** 1497 1497 1498 -((( 1499 1499 **Example:** 1500 -))) 1501 1501 1502 -((( 1503 1503 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1504 -))) 1505 1505 1506 -((( 1507 1507 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1508 -))) 1509 1509 1510 -((( 1511 - 1512 -))) 1513 1513 1514 -* ((( 1515 -**LoRaWAN Downlink Command:** 1516 -))) 1446 +* **LoRaWAN Downlink Command:** 1517 1517 1518 -((( 1519 1519 **07 01 aa bb** Same as AT+5VT=(aa bb) 1520 -))) 1521 1521 1522 -((( 1523 1523 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1524 -))) 1525 1525 1526 1526 1527 1527 ... ... @@ -1532,6 +1532,7 @@ 1532 1532 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1533 1533 1534 1534 1461 + 1535 1535 == 3.7 +3V3 Output == 1536 1536 1537 1537 ((( ... ... @@ -1610,14 +1610,21 @@ 1610 1610 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1611 1611 1612 1612 1540 + 1613 1613 == 3.10 Switch Jumper == 1614 1614 1615 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %) 1616 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 277px;" %)**Feature** 1617 -|(% style="width:123px" %)**SW1**|(% style="width:277px" %)ISP position: Upgrade firmware via UART 1543 +(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1544 +|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1545 +|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1546 +ISP position: Upgrade firmware via UART 1547 + 1618 1618 Flash position: Configure device, check running status. 1619 -|(% style="width:123px" %)**SW2**|(% style="width:277px" %)5V position: set to compatible with 5v I/O. 1549 +))) 1550 +|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1551 +5V position: set to compatible with 5v I/O. 1552 + 1620 1620 3.3v position: set to compatible with 3.3v I/O., 1554 +))) 1621 1621 1622 1622 ((( 1623 1623 **+3.3V**: is always ON ... ... @@ -1816,6 +1816,7 @@ 1816 1816 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1817 1817 1818 1818 1753 + 1819 1819 = 9. Packing Info = 1820 1820 1821 1821 (((