Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -94,6 +94,8 @@ 94 94 * 127 dB Dynamic Range RSSI. 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 97 + 98 + 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -105,6 +105,8 @@ 105 105 * Support Modbus protocol 106 106 * Support Interrupt uplink 107 107 110 + 111 + 108 108 == 1.4 Applications == 109 109 110 110 * Smart Buildings & Home Automation ... ... @@ -114,6 +114,8 @@ 114 114 * Smart Cities 115 115 * Smart Factory 116 116 121 + 122 + 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -382,6 +382,8 @@ 382 382 ))) 383 383 ))) 384 384 391 + 392 + 385 385 === 3.3.2 Configure sensors === 386 386 387 387 ((( ... ... @@ -395,11 +395,17 @@ 395 395 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 396 396 |=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 397 397 |AT+CFGDEV|(% style="width:80px" %)((( 406 +((( 398 398 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 408 +))) 399 399 410 +((( 400 400 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 412 +))) 401 401 414 +((( 402 402 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 416 +))) 403 403 )))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 404 404 405 405 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. ... ... @@ -870,7 +870,7 @@ 870 870 ))) 871 871 872 872 ((( 873 -} 887 +**}** 874 874 875 875 876 876 ))) ... ... @@ -901,7 +901,6 @@ 901 901 ))) 902 902 903 903 904 - 905 905 === 3.5.1 Common Commands: === 906 906 907 907 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1531,7 +1531,6 @@ 1531 1531 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1532 1532 1533 1533 1534 - 1535 1535 == 3.7 +3V3 Output == 1536 1536 1537 1537 ((( ... ... @@ -1612,11 +1612,11 @@ 1612 1612 1613 1613 == 3.10 Switch Jumper == 1614 1614 1615 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width: 509px" %)1616 -|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 3 82px;" %)**Feature**1617 -|(% style="width:123px" %)**SW1**|(% style="width:3 82px" %)ISP position: Upgrade firmware via UART1627 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1628 +|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1629 +|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1618 1618 Flash position: Configure device, check running status. 1619 -|(% style="width:123px" %)**SW2**|(% style="width:3 82px" %)5V position: set to compatible with 5v I/O.1631 +|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1620 1620 3.3v position: set to compatible with 3.3v I/O., 1621 1621 1622 1622 ((( ... ... @@ -1816,7 +1816,6 @@ 1816 1816 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1817 1817 1818 1818 1819 - 1820 1820 = 9. Packing Info = 1821 1821 1822 1822 (((