1488 1488  
1489 1489  ==== **Control output power duration** ====
1490 1490  
1491 -(((
1492 1492  User can set the output power duration before each sampling.
1493 -)))
1494 1494  
1495 -* (((
1496 -**AT Command:**
1497 -)))
1493 +* **AT Command:**
1498 1498  
1499 -(((
1500 1500  **Example:**
1501 -)))
1502 1502  
1503 -(((
1504 1504  **AT+3V3T=1000**  ~/~/ 3V3 output power will open 1s before each sampling.
1505 -)))
1506 1506  
1507 -(((
1508 1508  **AT+5VT=1000**  ~/~/ +5V output power will open 1s before each sampling.
1509 -)))
1510 1510  
1511 -(((
1512 -
1513 -)))
1514 1514  
1515 -* (((
1516 -**LoRaWAN Downlink Command:**
1517 -)))
1502 +* **LoRaWAN Downlink Command:**
1518 1518  
1519 -(((
1520 1520  **07 01 aa bb**  Same as AT+5VT=(aa bb)
1521 -)))
1522 1522  
1523 -(((
1524 1524  **07 02 aa bb**  Same as AT+3V3T=(aa bb)
1525 -)))
1526 1526  
1527 1527  
1528 1528