Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,13 +1,9 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1652947681187-144.png||height=" 385" width="385"]]2 +[[image:1652947681187-144.png||height="404" width="404"]] 3 3 4 4 5 5 6 6 7 -**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 - 9 - 10 - 11 11 **Table of Contents:** 12 12 13 13 {{toc/}} ... ... @@ -67,6 +67,7 @@ 67 67 ** Idle: 6uA@3.3v 68 68 ** 20dB Transmit: 130mA@3.3v 69 69 66 + 70 70 **Interface for Model:** 71 71 72 72 * 1 x RS485 Interface ... ... @@ -76,6 +76,7 @@ 76 76 * 1 x Interrupt Interface 77 77 * 1 x Controllable 5V output, max 78 78 76 + 79 79 **LoRa Spec:** 80 80 81 81 * Frequency Range: ... ... @@ -94,6 +94,9 @@ 94 94 * 127 dB Dynamic Range RSSI. 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 95 + 96 + 97 + 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -105,6 +105,9 @@ 105 105 * Support Modbus protocol 106 106 * Support Interrupt uplink 107 107 109 + 110 + 111 + 108 108 == 1.4 Applications == 109 109 110 110 * Smart Buildings & Home Automation ... ... @@ -114,6 +114,9 @@ 114 114 * Smart Cities 115 115 * Smart Factory 116 116 121 + 122 + 123 + 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -283,28 +283,28 @@ 283 283 ))) 284 284 285 285 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 286 -|=(% style="width: 120px;" %)(((293 +|=(% style="width: 80px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) 290 -)))|=(% style="width: 1 90px;" %)(((297 +)))|=(% style="width: 210px;" %)((( 291 291 ((( 292 292 **Description** 293 293 ))) 294 -)))|=(% style="width: 1 90px;" %)(((301 +)))|=(% style="width: 210px;" %)((( 295 295 ((( 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width: 120px" %)(((306 +|(% style="width:80px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) 303 -)))|(% style="width:1 90px" %)(((310 +)))|(% style="width:210px" %)((( 304 304 ((( 305 305 Set the baud rate (for RS485 connection). Default Value is: 9600. 306 306 ))) 307 -)))|(% style="width:1 90px" %)(((314 +)))|(% style="width:210px" %)((( 308 308 ((( 309 309 ((( 310 310 AT+BAUDR=9600 ... ... @@ -317,11 +317,11 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width: 120px" %)(((327 +|(% style="width:80px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) 324 -)))|(% style="width:1 90px" %)(((331 +)))|(% style="width:210px" %)((( 325 325 ((( 326 326 ((( 327 327 Set UART parity (for RS485 connection) ... ... @@ -333,7 +333,7 @@ 333 333 Default Value is: no parity. 334 334 ))) 335 335 ))) 336 -)))|(% style="width:1 90px" %)(((343 +)))|(% style="width:210px" %)((( 337 337 ((( 338 338 ((( 339 339 AT+PARITY=0 ... ... @@ -346,11 +346,11 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width: 120px" %)(((356 +|(% style="width:80px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) 353 -)))|(% style="width:1 90px" %)(((360 +)))|(% style="width:210px" %)((( 354 354 ((( 355 355 ((( 356 356 Set serial stopbit (for RS485 connection) ... ... @@ -362,7 +362,7 @@ 362 362 Default Value is: 1bit. 363 363 ))) 364 364 ))) 365 -)))|(% style="width:1 90px" %)(((372 +)))|(% style="width:210px" %)((( 366 366 ((( 367 367 ((( 368 368 AT+STOPBIT=0 for 1bit ... ... @@ -382,8 +382,6 @@ 382 382 ))) 383 383 ))) 384 384 385 - 386 - 387 387 === 3.3.2 Configure sensors === 388 388 389 389 ((( ... ... @@ -395,14 +395,20 @@ 395 395 ))) 396 396 397 397 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 398 -|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 -|AT+CFGDEV|(% style="width:120px" %)((( 403 +|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 404 +|AT+CFGDEV|(% style="width:80px" %)((( 405 +((( 400 400 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 407 +))) 401 401 409 +((( 402 402 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 411 +))) 403 403 413 +((( 404 404 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 405 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 415 +))) 416 +)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 406 406 407 407 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 408 408 ... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - {{{}}}}886 +**}** 876 876 877 877 878 878 ))) ... ... @@ -902,8 +902,6 @@ 902 902 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 903 903 ))) 904 904 905 - 906 - 907 907 === 3.5.1 Common Commands: === 908 908 909 909 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1427,34 +1427,16 @@ 1427 1427 ((( 1428 1428 ((( 1429 1429 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1430 -))) 1431 -))) 1432 1432 1433 -((( 1434 1434 Set UART Parity 1435 -))) 1436 - 1437 -(% class="box infomessage" %) 1438 -((( 1439 -((( 1440 1440 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1441 -))) 1442 -))) 1443 1443 1444 -((( 1445 1445 Set STOPBIT 1446 -))) 1447 1447 1448 -(% class="box infomessage" %) 1449 -((( 1450 -((( 1451 1451 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1452 1452 ))) 1453 1453 ))) 1454 1454 1455 -((( 1456 - 1457 -))) 1458 1458 1459 1459 * ((( 1460 1460 **Downlink Payload:** ... ... @@ -1488,22 +1488,41 @@ 1488 1488 1489 1489 ==== **Control output power duration** ==== 1490 1490 1482 +((( 1491 1491 User can set the output power duration before each sampling. 1484 +))) 1492 1492 1493 -* **AT Command:** 1486 +* ((( 1487 +**AT Command:** 1488 +))) 1494 1494 1490 +((( 1495 1495 **Example:** 1492 +))) 1496 1496 1494 +((( 1497 1497 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1496 +))) 1498 1498 1498 +((( 1499 1499 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1500 +))) 1500 1500 1502 +((( 1503 + 1504 +))) 1501 1501 1502 -* **LoRaWAN Downlink Command:** 1506 +* ((( 1507 +**LoRaWAN Downlink Command:** 1508 +))) 1503 1503 1510 +((( 1504 1504 **07 01 aa bb** Same as AT+5VT=(aa bb) 1512 +))) 1505 1505 1514 +((( 1506 1506 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1516 +))) 1507 1507 1508 1508 1509 1509 ... ... @@ -1513,8 +1513,6 @@ 1513 1513 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1514 1514 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1515 1515 1516 - 1517 - 1518 1518 == 3.7 +3V3 Output == 1519 1519 1520 1520 ((( ... ... @@ -1592,22 +1592,14 @@ 1592 1592 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1593 1593 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1594 1594 1595 - 1596 - 1597 1597 == 3.10 Switch Jumper == 1598 1598 1599 -(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1600 -|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1601 -|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1602 -ISP position: Upgrade firmware via UART 1603 - 1605 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1606 +|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1607 +|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1604 1604 Flash position: Configure device, check running status. 1605 -))) 1606 -|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1607 -5V position: set to compatible with 5v I/O. 1608 - 1609 +|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1609 1609 3.3v position: set to compatible with 3.3v I/O., 1610 -))) 1611 1611 1612 1612 ((( 1613 1613 **+3.3V**: is always ON ... ... @@ -1655,15 +1655,7 @@ 1655 1655 (% class="box infomessage" %) 1656 1656 ((( 1657 1657 **AT+FDR** 1658 -))) 1659 - 1660 -(% class="box infomessage" %) 1661 -((( 1662 1662 **AT+NJM=0** 1663 -))) 1664 - 1665 -(% class="box infomessage" %) 1666 -((( 1667 1667 **ATZ** 1668 1668 ))) 1669 1669 ... ... @@ -1805,8 +1805,6 @@ 1805 1805 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1806 1806 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1807 1807 1808 - 1809 - 1810 1810 = 9. Packing Info = 1811 1811 1812 1812 (((