Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,13 +1,9 @@ 1 1 (% style="text-align:center" %) 2 -[[image:1652947681187-144.png||height=" 385" width="385"]]2 +[[image:1652947681187-144.png||height="404" width="404"]] 3 3 4 4 5 5 6 6 7 -**RS485-BL – Waterproof RS485 to LoRaWAN Converter User Manual** 8 - 9 - 10 - 11 11 **Table of Contents:** 12 12 13 13 {{toc/}} ... ... @@ -67,6 +67,7 @@ 67 67 ** Idle: 6uA@3.3v 68 68 ** 20dB Transmit: 130mA@3.3v 69 69 66 + 70 70 **Interface for Model:** 71 71 72 72 * 1 x RS485 Interface ... ... @@ -76,6 +76,7 @@ 76 76 * 1 x Interrupt Interface 77 77 * 1 x Controllable 5V output, max 78 78 76 + 79 79 **LoRa Spec:** 80 80 81 81 * Frequency Range: ... ... @@ -94,6 +94,9 @@ 94 94 * 127 dB Dynamic Range RSSI. 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 95 + 96 + 97 + 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -105,6 +105,9 @@ 105 105 * Support Modbus protocol 106 106 * Support Interrupt uplink 107 107 109 + 110 + 111 + 108 108 == 1.4 Applications == 109 109 110 110 * Smart Buildings & Home Automation ... ... @@ -114,6 +114,9 @@ 114 114 * Smart Cities 115 115 * Smart Factory 116 116 121 + 122 + 123 + 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -197,6 +197,7 @@ 197 197 198 198 [[image:1652953414711-647.png||height="337" width="723"]] 199 199 207 + 200 200 ((( 201 201 The RS485-BL in this example connected to two RS485 devices for demonstration, user can connect to other RS485 devices via the same method. 202 202 ))) ... ... @@ -215,12 +215,13 @@ 215 215 216 216 [[image:1652953462722-299.png]] 217 217 226 + 218 218 ((( 219 219 User can enter this key in their LoRaWAN Server portal. Below is TTN V3 screen shot: 220 220 ))) 221 221 222 222 ((( 223 -Add APP EUI in the application. 232 +**Add APP EUI in the application.** 224 224 ))) 225 225 226 226 ... ... @@ -232,15 +232,18 @@ 232 232 233 233 [[image:image-20220519174512-4.png]] 234 234 244 + 235 235 You can also choose to create the device manually. 236 236 237 237 [[image:1652953542269-423.png||height="710" width="723"]] 238 238 249 + 239 239 Add APP KEY and DEV EUI 240 240 241 241 [[image:1652953553383-907.png||height="514" width="724"]] 242 242 243 243 255 + 244 244 ((( 245 245 **Step 2**: Power on RS485-BL and it will auto join to the TTN V3 network. After join success, it will start to upload message to TTN V3 and user can see in the panel. 246 246 ))) ... ... @@ -283,28 +283,28 @@ 283 283 ))) 284 284 285 285 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 286 -|=(% style="width: 120px;" %)(((298 +|=(% style="width: 80px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) 290 -)))|=(% style="width: 1 90px;" %)(((302 +)))|=(% style="width: 210px;" %)((( 291 291 ((( 292 292 **Description** 293 293 ))) 294 -)))|=(% style="width: 1 90px;" %)(((306 +)))|=(% style="width: 210px;" %)((( 295 295 ((( 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width: 120px" %)(((311 +|(% style="width:80px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) 303 -)))|(% style="width:1 90px" %)(((315 +)))|(% style="width:210px" %)((( 304 304 ((( 305 305 Set the baud rate (for RS485 connection). Default Value is: 9600. 306 306 ))) 307 -)))|(% style="width:1 90px" %)(((319 +)))|(% style="width:210px" %)((( 308 308 ((( 309 309 ((( 310 310 AT+BAUDR=9600 ... ... @@ -317,11 +317,11 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width: 120px" %)(((332 +|(% style="width:80px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) 324 -)))|(% style="width:1 90px" %)(((336 +)))|(% style="width:210px" %)((( 325 325 ((( 326 326 ((( 327 327 Set UART parity (for RS485 connection) ... ... @@ -333,7 +333,7 @@ 333 333 Default Value is: no parity. 334 334 ))) 335 335 ))) 336 -)))|(% style="width:1 90px" %)(((348 +)))|(% style="width:210px" %)((( 337 337 ((( 338 338 ((( 339 339 AT+PARITY=0 ... ... @@ -346,11 +346,11 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width: 120px" %)(((361 +|(% style="width:80px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) 353 -)))|(% style="width:1 90px" %)(((365 +)))|(% style="width:210px" %)((( 354 354 ((( 355 355 ((( 356 356 Set serial stopbit (for RS485 connection) ... ... @@ -362,7 +362,7 @@ 362 362 Default Value is: 1bit. 363 363 ))) 364 364 ))) 365 -)))|(% style="width:1 90px" %)(((377 +)))|(% style="width:210px" %)((( 366 366 ((( 367 367 ((( 368 368 AT+STOPBIT=0 for 1bit ... ... @@ -382,8 +382,6 @@ 382 382 ))) 383 383 ))) 384 384 385 - 386 - 387 387 === 3.3.2 Configure sensors === 388 388 389 389 ((( ... ... @@ -395,14 +395,20 @@ 395 395 ))) 396 396 397 397 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 398 -|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 -|AT+CFGDEV|(% style="width:120px" %)((( 408 +|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 409 +|AT+CFGDEV|(% style="width:80px" %)((( 410 +((( 400 400 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 412 +))) 401 401 414 +((( 402 402 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 416 +))) 403 403 418 +((( 404 404 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 405 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 420 +))) 421 +)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 406 406 407 407 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 408 408 ... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - {{{}}}}891 +**}** 876 876 877 877 878 878 ))) ... ... @@ -902,8 +902,6 @@ 902 902 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 903 903 ))) 904 904 905 - 906 - 907 907 === 3.5.1 Common Commands: === 908 908 909 909 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1427,34 +1427,16 @@ 1427 1427 ((( 1428 1428 ((( 1429 1429 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1430 -))) 1431 -))) 1432 1432 1433 -((( 1434 1434 Set UART Parity 1435 -))) 1436 - 1437 -(% class="box infomessage" %) 1438 -((( 1439 -((( 1440 1440 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1441 -))) 1442 -))) 1443 1443 1444 -((( 1445 1445 Set STOPBIT 1446 -))) 1447 1447 1448 -(% class="box infomessage" %) 1449 -((( 1450 -((( 1451 1451 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1452 1452 ))) 1453 1453 ))) 1454 1454 1455 -((( 1456 - 1457 -))) 1458 1458 1459 1459 * ((( 1460 1460 **Downlink Payload:** ... ... @@ -1488,22 +1488,41 @@ 1488 1488 1489 1489 ==== **Control output power duration** ==== 1490 1490 1487 +((( 1491 1491 User can set the output power duration before each sampling. 1489 +))) 1492 1492 1493 -* **AT Command:** 1491 +* ((( 1492 +**AT Command:** 1493 +))) 1494 1494 1495 +((( 1495 1495 **Example:** 1497 +))) 1496 1496 1499 +((( 1497 1497 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1501 +))) 1498 1498 1503 +((( 1499 1499 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1505 +))) 1500 1500 1507 +((( 1508 + 1509 +))) 1501 1501 1502 -* **LoRaWAN Downlink Command:** 1511 +* ((( 1512 +**LoRaWAN Downlink Command:** 1513 +))) 1503 1503 1515 +((( 1504 1504 **07 01 aa bb** Same as AT+5VT=(aa bb) 1517 +))) 1505 1505 1519 +((( 1506 1506 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1521 +))) 1507 1507 1508 1508 1509 1509 ... ... @@ -1513,8 +1513,6 @@ 1513 1513 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1514 1514 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1515 1515 1516 - 1517 - 1518 1518 == 3.7 +3V3 Output == 1519 1519 1520 1520 ((( ... ... @@ -1592,22 +1592,14 @@ 1592 1592 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1593 1593 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1594 1594 1595 - 1596 - 1597 1597 == 3.10 Switch Jumper == 1598 1598 1599 -(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1600 -|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1601 -|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1602 -ISP position: Upgrade firmware via UART 1603 - 1610 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1611 +|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1612 +|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1604 1604 Flash position: Configure device, check running status. 1605 -))) 1606 -|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1607 -5V position: set to compatible with 5v I/O. 1608 - 1614 +|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1609 1609 3.3v position: set to compatible with 3.3v I/O., 1610 -))) 1611 1611 1612 1612 ((( 1613 1613 **+3.3V**: is always ON ... ... @@ -1655,15 +1655,7 @@ 1655 1655 (% class="box infomessage" %) 1656 1656 ((( 1657 1657 **AT+FDR** 1658 -))) 1659 - 1660 -(% class="box infomessage" %) 1661 -((( 1662 1662 **AT+NJM=0** 1663 -))) 1664 - 1665 -(% class="box infomessage" %) 1666 -((( 1667 1667 **ATZ** 1668 1668 ))) 1669 1669 ... ... @@ -1805,8 +1805,6 @@ 1805 1805 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1806 1806 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1807 1807 1808 - 1809 - 1810 1810 = 9. Packing Info = 1811 1811 1812 1812 (((