Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -283,28 +283,28 @@ 283 283 ))) 284 284 285 285 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 286 -|=(% style="width: 120px;" %)(((286 +|=(% style="width: 80px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) 290 -)))|=(% style="width: 1 90px;" %)(((290 +)))|=(% style="width: 210px;" %)((( 291 291 ((( 292 292 **Description** 293 293 ))) 294 -)))|=(% style="width: 1 90px;" %)(((294 +)))|=(% style="width: 210px;" %)((( 295 295 ((( 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width: 120px" %)(((299 +|(% style="width:80px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) 303 -)))|(% style="width:1 90px" %)(((303 +)))|(% style="width:210px" %)((( 304 304 ((( 305 305 Set the baud rate (for RS485 connection). Default Value is: 9600. 306 306 ))) 307 -)))|(% style="width:1 90px" %)(((307 +)))|(% style="width:210px" %)((( 308 308 ((( 309 309 ((( 310 310 AT+BAUDR=9600 ... ... @@ -317,11 +317,11 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width: 120px" %)(((320 +|(% style="width:80px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) 324 -)))|(% style="width:1 90px" %)(((324 +)))|(% style="width:210px" %)((( 325 325 ((( 326 326 ((( 327 327 Set UART parity (for RS485 connection) ... ... @@ -333,7 +333,7 @@ 333 333 Default Value is: no parity. 334 334 ))) 335 335 ))) 336 -)))|(% style="width:1 90px" %)(((336 +)))|(% style="width:210px" %)((( 337 337 ((( 338 338 ((( 339 339 AT+PARITY=0 ... ... @@ -346,11 +346,11 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width: 120px" %)(((349 +|(% style="width:80px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) 353 -)))|(% style="width:1 90px" %)(((353 +)))|(% style="width:210px" %)((( 354 354 ((( 355 355 ((( 356 356 Set serial stopbit (for RS485 connection) ... ... @@ -362,7 +362,7 @@ 362 362 Default Value is: 1bit. 363 363 ))) 364 364 ))) 365 -)))|(% style="width:1 90px" %)(((365 +)))|(% style="width:210px" %)((( 366 366 ((( 367 367 ((( 368 368 AT+STOPBIT=0 for 1bit ... ... @@ -383,7 +383,6 @@ 383 383 ))) 384 384 385 385 386 - 387 387 === 3.3.2 Configure sensors === 388 388 389 389 ((( ... ... @@ -395,14 +395,14 @@ 395 395 ))) 396 396 397 397 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 398 -|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**399 -|AT+CFGDEV|(% style="width: 120px" %)(((397 +|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 398 +|AT+CFGDEV|(% style="width:80px" %)((( 400 400 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 401 401 402 402 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 403 403 404 404 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 405 -)))|(% style="width:1 90px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m404 +)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 406 406 407 407 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 408 408 ... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - {{{}}}}874 +} 876 876 877 877 878 878 ))) ... ... @@ -903,7 +903,6 @@ 903 903 ))) 904 904 905 905 906 - 907 907 === 3.5.1 Common Commands: === 908 908 909 909 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1488,22 +1488,41 @@ 1488 1488 1489 1489 ==== **Control output power duration** ==== 1490 1490 1489 +((( 1491 1491 User can set the output power duration before each sampling. 1491 +))) 1492 1492 1493 -* **AT Command:** 1493 +* ((( 1494 +**AT Command:** 1495 +))) 1494 1494 1497 +((( 1495 1495 **Example:** 1499 +))) 1496 1496 1501 +((( 1497 1497 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1503 +))) 1498 1498 1505 +((( 1499 1499 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1507 +))) 1500 1500 1509 +((( 1510 + 1511 +))) 1501 1501 1502 -* **LoRaWAN Downlink Command:** 1513 +* ((( 1514 +**LoRaWAN Downlink Command:** 1515 +))) 1503 1503 1517 +((( 1504 1504 **07 01 aa bb** Same as AT+5VT=(aa bb) 1519 +))) 1505 1505 1521 +((( 1506 1506 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1523 +))) 1507 1507 1508 1508 1509 1509 ... ... @@ -1514,7 +1514,6 @@ 1514 1514 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1515 1515 1516 1516 1517 - 1518 1518 == 3.7 +3V3 Output == 1519 1519 1520 1520 ((( ... ... @@ -1593,7 +1593,6 @@ 1593 1593 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1594 1594 1595 1595 1596 - 1597 1597 == 3.10 Switch Jumper == 1598 1598 1599 1599 (% border="1" style="background-color:#ffffcc; color:green; width:515px" %) ... ... @@ -1806,7 +1806,6 @@ 1806 1806 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1807 1807 1808 1808 1809 - 1810 1810 = 9. Packing Info = 1811 1811 1812 1812 (((