Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -94,6 +94,8 @@ 94 94 * 127 dB Dynamic Range RSSI. 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 97 + 98 + 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -283,28 +283,28 @@ 283 283 ))) 284 284 285 285 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 286 -|=(% style="width: 120px;" %)(((288 +|=(% style="width: 80px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) 290 -)))|=(% style="width: 1 90px;" %)(((292 +)))|=(% style="width: 210px;" %)((( 291 291 ((( 292 292 **Description** 293 293 ))) 294 -)))|=(% style="width: 1 90px;" %)(((296 +)))|=(% style="width: 210px;" %)((( 295 295 ((( 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width: 120px" %)(((301 +|(% style="width:80px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) 303 -)))|(% style="width:1 90px" %)(((305 +)))|(% style="width:210px" %)((( 304 304 ((( 305 305 Set the baud rate (for RS485 connection). Default Value is: 9600. 306 306 ))) 307 -)))|(% style="width:1 90px" %)(((309 +)))|(% style="width:210px" %)((( 308 308 ((( 309 309 ((( 310 310 AT+BAUDR=9600 ... ... @@ -317,11 +317,11 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width: 120px" %)(((322 +|(% style="width:80px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) 324 -)))|(% style="width:1 90px" %)(((326 +)))|(% style="width:210px" %)((( 325 325 ((( 326 326 ((( 327 327 Set UART parity (for RS485 connection) ... ... @@ -333,7 +333,7 @@ 333 333 Default Value is: no parity. 334 334 ))) 335 335 ))) 336 -)))|(% style="width:1 90px" %)(((338 +)))|(% style="width:210px" %)((( 337 337 ((( 338 338 ((( 339 339 AT+PARITY=0 ... ... @@ -346,11 +346,11 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width: 120px" %)(((351 +|(% style="width:80px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) 353 -)))|(% style="width:1 90px" %)(((355 +)))|(% style="width:210px" %)((( 354 354 ((( 355 355 ((( 356 356 Set serial stopbit (for RS485 connection) ... ... @@ -362,7 +362,7 @@ 362 362 Default Value is: 1bit. 363 363 ))) 364 364 ))) 365 -)))|(% style="width:1 90px" %)(((367 +)))|(% style="width:210px" %)((( 366 366 ((( 367 367 ((( 368 368 AT+STOPBIT=0 for 1bit ... ... @@ -382,8 +382,6 @@ 382 382 ))) 383 383 ))) 384 384 385 - 386 - 387 387 === 3.3.2 Configure sensors === 388 388 389 389 ((( ... ... @@ -395,14 +395,14 @@ 395 395 ))) 396 396 397 397 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 398 -|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**399 -|AT+CFGDEV|(% style="width: 120px" %)(((398 +|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 399 +|AT+CFGDEV|(% style="width:80px" %)((( 400 400 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 401 401 402 402 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 403 403 404 404 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 405 -)))|(% style="width:1 90px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m405 +)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 406 406 407 407 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 408 408 ... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - {{{}}}}875 +} 876 876 877 877 878 878 ))) ... ... @@ -903,7 +903,6 @@ 903 903 ))) 904 904 905 905 906 - 907 907 === 3.5.1 Common Commands: === 908 908 909 909 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1488,22 +1488,41 @@ 1488 1488 1489 1489 ==== **Control output power duration** ==== 1490 1490 1490 +((( 1491 1491 User can set the output power duration before each sampling. 1492 +))) 1492 1492 1493 -* **AT Command:** 1494 +* ((( 1495 +**AT Command:** 1496 +))) 1494 1494 1498 +((( 1495 1495 **Example:** 1500 +))) 1496 1496 1502 +((( 1497 1497 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1504 +))) 1498 1498 1506 +((( 1499 1499 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1508 +))) 1500 1500 1510 +((( 1511 + 1512 +))) 1501 1501 1502 -* **LoRaWAN Downlink Command:** 1514 +* ((( 1515 +**LoRaWAN Downlink Command:** 1516 +))) 1503 1503 1518 +((( 1504 1504 **07 01 aa bb** Same as AT+5VT=(aa bb) 1520 +))) 1505 1505 1522 +((( 1506 1506 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1524 +))) 1507 1507 1508 1508 1509 1509 ... ... @@ -1514,7 +1514,6 @@ 1514 1514 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1515 1515 1516 1516 1517 - 1518 1518 == 3.7 +3V3 Output == 1519 1519 1520 1520 ((( ... ... @@ -1593,21 +1593,14 @@ 1593 1593 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1594 1594 1595 1595 1596 - 1597 1597 == 3.10 Switch Jumper == 1598 1598 1599 -(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1600 -|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1601 -|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1602 -ISP position: Upgrade firmware via UART 1603 - 1615 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:400px" %) 1616 +|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 277px;" %)**Feature** 1617 +|(% style="width:123px" %)**SW1**|(% style="width:277px" %)ISP position: Upgrade firmware via UART 1604 1604 Flash position: Configure device, check running status. 1605 -))) 1606 -|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1607 -5V position: set to compatible with 5v I/O. 1608 - 1619 +|(% style="width:123px" %)**SW2**|(% style="width:277px" %)5V position: set to compatible with 5v I/O. 1609 1609 3.3v position: set to compatible with 3.3v I/O., 1610 -))) 1611 1611 1612 1612 ((( 1613 1613 **+3.3V**: is always ON ... ... @@ -1806,7 +1806,6 @@ 1806 1806 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1807 1807 1808 1808 1809 - 1810 1810 = 9. Packing Info = 1811 1811 1812 1812 (((