... ... @@ -510,6 +510,10 @@
510 510  )))
511 511  
512 512  (((
513 +
514 +)))
515 +
516 +(((
513 513  **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
514 514  )))
515 515  
... ... @@ -882,13 +882,21 @@
882 882  
883 883  == 3.5 Configure RS485-BL via AT or Downlink ==
884 884  
889 +(((
885 885  User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands
891 +)))
886 886  
893 +(((
887 887  There are two kinds of Commands:
895 +)))
888 888  
889 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
897 +* (((
898 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
899 +)))
890 890  
891 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
901 +* (((
902 +(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
903 +)))
892 892  
893 893  
894 894  
... ... @@ -900,6 +900,7 @@
900 900  === 3.5.2 Sensor related commands: ===
901 901  
902 902  
915 +
903 903  ==== **Choose Device Type (RS485 or TTL)** ====
904 904  
905 905  RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
... ... @@ -923,6 +923,7 @@
923 923  
924 924  
925 925  
939 +
926 926  ==== **RS485 Debug Command (AT+CFGDEV)** ====
927 927  
928 928  This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling.
... ... @@ -962,7 +962,9 @@
962 962  
963 963  (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
964 964  
979 +(((
965 965  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
981 +)))
966 966  
967 967  
968 968  **Example 2:**
... ... @@ -974,6 +974,7 @@
974 974  
975 975  
976 976  
993 +
977 977  ==== **Set Payload version** ====
978 978  
979 979  This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload.
... ... @@ -994,6 +994,7 @@
994 994  
995 995  
996 996  
1014 +
997 997  ==== **Set RS485 Sampling Commands** ====
998 998  
999 999  AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
... ... @@ -1055,6 +1055,7 @@
1055 1055  
1056 1056  
1057 1057  
1076 +
1058 1058  ==== **Fast command to handle MODBUS device** ====
1059 1059  
1060 1060  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
... ... @@ -1088,6 +1088,7 @@
1088 1088  
1089 1089  
1090 1090  
1110 +
1091 1091  ==== **RS485 command timeout** ====
1092 1092  
1093 1093  Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
... ... @@ -1119,6 +1119,7 @@
1119 1119  
1120 1120  
1121 1121  
1142 +
1122 1122  ==== **Uplink payload mode** ====
1123 1123  
1124 1124  Define to use one uplink or multiple uplinks for the sampling.
... ... @@ -1165,7 +1165,9 @@
1165 1165  
1166 1166  * **AT Command:**
1167 1167  
1189 +(((
1168 1168  (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1191 +)))
1169 1169  
1170 1170  Example screen shot after clear all RS485 commands. 
1171 1171  
... ... @@ -1181,6 +1181,7 @@
1181 1181  
1182 1182  
1183 1183  
1207 +
1184 1184  ==== **Set Serial Communication Parameters** ====
1185 1185  
1186 1186  Set the Rs485 serial communication parameters:
... ... @@ -1224,6 +1224,7 @@
1224 1224  
1225 1225  
1226 1226  
1251 +
1227 1227  ==== **Control output power duration** ====
1228 1228  
1229 1229  User can set the output power duration before each sampling.
... ... @@ -1251,6 +1251,8 @@
1251 1251  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1252 1252  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1253 1253  
1279 +
1280 +
1254 1254  == 3.7 +3V3 Output ==