... ... @@ -283,28 +283,28 @@
283 283  )))
284 284  
285 285  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
286 -|=(% style="width: 120px;" %)(((
286 +|=(% style="width: 80px;" %)(((
287 287  (((
288 288  **AT Commands**
289 289  )))
290 -)))|=(% style="width: 190px;" %)(((
290 +)))|=(% style="width: 210px;" %)(((
291 291  (((
292 292  **Description**
293 293  )))
294 -)))|=(% style="width: 190px;" %)(((
294 +)))|=(% style="width: 2100px;" %)(((
295 295  (((
296 296  **Example**
297 297  )))
298 298  )))
299 -|(% style="width:120px" %)(((
299 +|(% style="width:80px" %)(((
300 300  (((
301 301  AT+BAUDR
302 302  )))
303 -)))|(% style="width:190px" %)(((
303 +)))|(% style="width:210px" %)(((
304 304  (((
305 305  Set the baud rate (for RS485 connection). Default Value is: 9600.
306 306  )))
307 -)))|(% style="width:190px" %)(((
307 +)))|(% style="width:210px" %)(((
308 308  (((
309 309  (((
310 310  AT+BAUDR=9600
... ... @@ -317,11 +317,11 @@
317 317  )))
318 318  )))
319 319  )))
320 -|(% style="width:120px" %)(((
320 +|(% style="width:80px" %)(((
321 321  (((
322 322  AT+PARITY
323 323  )))
324 -)))|(% style="width:190px" %)(((
324 +)))|(% style="width:210px" %)(((
325 325  (((
326 326  (((
327 327  Set UART parity (for RS485 connection)
... ... @@ -333,7 +333,7 @@
333 333  Default Value is: no parity.
334 334  )))
335 335  )))
336 -)))|(% style="width:190px" %)(((
336 +)))|(% style="width:210px" %)(((
337 337  (((
338 338  (((
339 339  AT+PARITY=0
... ... @@ -346,11 +346,11 @@
346 346  )))
347 347  )))
348 348  )))
349 -|(% style="width:120px" %)(((
349 +|(% style="width:80px" %)(((
350 350  (((
351 351  AT+STOPBIT
352 352  )))
353 -)))|(% style="width:190px" %)(((
353 +)))|(% style="width:210px" %)(((
354 354  (((
355 355  (((
356 356  Set serial stopbit (for RS485 connection)
... ... @@ -362,7 +362,7 @@
362 362  Default Value is: 1bit.
363 363  )))
364 364  )))
365 -)))|(% style="width:190px" %)(((
365 +)))|(% style="width:210px" %)(((
366 366  (((
367 367  (((
368 368  AT+STOPBIT=0 for 1bit
... ... @@ -382,8 +382,6 @@
382 382  )))
383 383  )))
384 384  
385 -
386 -
387 387  === 3.3.2 Configure sensors ===
388 388  
389 389  (((
... ... @@ -395,14 +395,14 @@
395 395  )))
396 396  
397 397  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
398 -|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
399 -|AT+CFGDEV|(% style="width:120px" %)(((
396 +|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example**
397 +|AT+CFGDEV|(% style="width:80px" %)(((
400 400  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
401 401  
402 402  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
403 403  
404 404  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
405 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
403 +)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
406 406  
407 407  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
408 408  
... ... @@ -872,7 +872,7 @@
872 872  )))
873 873  
874 874  (((
875 -{{{}}}}
873 +}
876 876  
877 877  
878 878  )))
... ... @@ -902,8 +902,6 @@
902 902  (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
903 903  )))
904 904  
905 -
906 -
907 907  === 3.5.1 Common Commands: ===
908 908  
909 909  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1362,26 +1362,49 @@
1362 1362  
1363 1363  ==== **Clear RS485 Command** ====
1364 1364  
1361 +(((
1365 1365  The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them.
1363 +)))
1366 1366  
1365 +(((
1366 +
1367 +)))
1367 1367  
1368 -* **AT Command:**
1369 +* (((
1370 +**AT Command:**
1371 +)))
1369 1369  
1370 1370  (((
1371 1371  (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1372 1372  )))
1373 1373  
1377 +(((
1374 1374  Example screen shot after clear all RS485 commands. 
1379 +)))
1375 1375  
1381 +(((
1382 +
1383 +)))
1376 1376  
1385 +(((
1377 1377  The uplink screen shot is:
1387 +)))
1378 1378  
1389 +(((
1379 1379  [[image:1654134704555-320.png]]
1391 +)))
1380 1380  
1393 +(((
1394 +
1395 +)))
1381 1381  
1382 -* **Downlink Payload:**
1397 +* (((
1398 +**Downlink Payload:**
1399 +)))
1383 1383  
1401 +(((
1384 1384  **0x09 aa bb** same as AT+CMDEAR=aa,bb
1403 +)))
1385 1385  
1386 1386  
1387 1387  
... ... @@ -1388,44 +1388,77 @@
1388 1388  
1389 1389  ==== **Set Serial Communication Parameters** ====
1390 1390  
1410 +(((
1391 1391  Set the Rs485 serial communication parameters:
1412 +)))
1392 1392  
1393 -* **AT Command:**
1414 +* (((
1415 +**AT Command:**
1416 +)))
1394 1394  
1418 +(((
1395 1395  Set Baud Rate:
1420 +)))
1396 1396  
1397 1397  (% class="box infomessage" %)
1398 1398  (((
1424 +(((
1399 1399  **AT+BAUDR=9600**    ~/~/ Options: (1200,2400,4800,14400,19200,115200)
1400 1400  )))
1427 +)))
1401 1401  
1429 +(((
1402 1402  Set UART Parity
1431 +)))
1403 1403  
1404 1404  (% class="box infomessage" %)
1405 1405  (((
1435 +(((
1406 1406  **AT+PARITY=0**    ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity
1407 1407  )))
1438 +)))
1408 1408  
1440 +(((
1409 1409  Set STOPBIT
1442 +)))
1410 1410  
1411 1411  (% class="box infomessage" %)
1412 1412  (((
1446 +(((
1413 1413  **AT+STOPBIT=0**    ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits
1414 1414  )))
1449 +)))
1415 1415  
1451 +(((
1452 +
1453 +)))
1416 1416  
1417 -* **Downlink Payload:**
1455 +* (((
1456 +**Downlink Payload:**
1457 +)))
1418 1418  
1459 +(((
1419 1419  **A7 01 aa bb**: Same  AT+BAUDR=hex(aa bb)*100
1461 +)))
1420 1420  
1463 +(((
1421 1421  **Example:**
1465 +)))
1422 1422  
1423 -* A7 01 00 60   same as AT+BAUDR=9600
1424 -* A7 01 04 80  same as AT+BAUDR=115200
1467 +* (((
1468 +A7 01 00 60   same as AT+BAUDR=9600
1469 +)))
1470 +* (((
1471 +A7 01 04 80  same as AT+BAUDR=115200
1472 +)))
1425 1425  
1474 +(((
1426 1426  A7 02 aa: Same as  AT+PARITY=aa  (aa value: 00 , 01 or 02)
1476 +)))
1427 1427  
1478 +(((
1428 1428  A7 03 aa: Same as  AT+STOPBIT=aa  (aa value: 00 , 01 or 02)
1480 +)))
1429 1429  
1430 1430  
1431 1431  
... ... @@ -1432,22 +1432,41 @@
1432 1432  
1433 1433  ==== **Control output power duration** ====
1434 1434  
1487 +(((
1435 1435  User can set the output power duration before each sampling.
1489 +)))
1436 1436  
1437 -* **AT Command:**
1491 +* (((
1492 +**AT Command:**
1493 +)))
1438 1438  
1495 +(((
1439 1439  **Example:**
1497 +)))
1440 1440  
1499 +(((
1441 1441  **AT+3V3T=1000**  ~/~/ 3V3 output power will open 1s before each sampling.
1501 +)))
1442 1442  
1503 +(((
1443 1443  **AT+5VT=1000**  ~/~/ +5V output power will open 1s before each sampling.
1505 +)))
1444 1444  
1507 +(((
1508 +
1509 +)))
1445 1445  
1446 -* **LoRaWAN Downlink Command:**
1511 +* (((
1512 +**LoRaWAN Downlink Command:**
1513 +)))
1447 1447  
1515 +(((
1448 1448  **07 01 aa bb**  Same as AT+5VT=(aa bb)
1517 +)))
1449 1449  
1519 +(((
1450 1450  **07 02 aa bb**  Same as AT+3V3T=(aa bb)
1521 +)))
1451 1451  
1452 1452  
1453 1453  
... ... @@ -1457,8 +1457,6 @@
1457 1457  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1458 1458  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1459 1459  
1460 -
1461 -
1462 1462  == 3.7 +3V3 Output ==
1463 1463  
1464 1464  (((
... ... @@ -1536,8 +1536,6 @@
1536 1536  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1537 1537  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1538 1538  
1539 -
1540 -
1541 1541  == 3.10 Switch Jumper ==
1542 1542  
1543 1543  (% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
... ... @@ -1749,8 +1749,6 @@
1749 1749  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1750 1750  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1751 1751  
1752 -
1753 -
1754 1754  = 9. Packing Info =
1755 1755  
1756 1756  (((