Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -283,28 +283,28 @@ 283 283 ))) 284 284 285 285 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 286 -|=(% style="width: 120px;" %)(((286 +|=(% style="width: 80px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) 290 -)))|=(% style="width: 1 90px;" %)(((290 +)))|=(% style="width: 210px;" %)((( 291 291 ((( 292 292 **Description** 293 293 ))) 294 -)))|=(% style="width: 1 90px;" %)(((294 +)))|=(% style="width: 2100px;" %)((( 295 295 ((( 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width: 120px" %)(((299 +|(% style="width:80px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) 303 -)))|(% style="width:1 90px" %)(((303 +)))|(% style="width:210px" %)((( 304 304 ((( 305 305 Set the baud rate (for RS485 connection). Default Value is: 9600. 306 306 ))) 307 -)))|(% style="width:1 90px" %)(((307 +)))|(% style="width:210px" %)((( 308 308 ((( 309 309 ((( 310 310 AT+BAUDR=9600 ... ... @@ -317,11 +317,11 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width: 120px" %)(((320 +|(% style="width:80px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) 324 -)))|(% style="width:1 90px" %)(((324 +)))|(% style="width:210px" %)((( 325 325 ((( 326 326 ((( 327 327 Set UART parity (for RS485 connection) ... ... @@ -333,7 +333,7 @@ 333 333 Default Value is: no parity. 334 334 ))) 335 335 ))) 336 -)))|(% style="width:1 90px" %)(((336 +)))|(% style="width:210px" %)((( 337 337 ((( 338 338 ((( 339 339 AT+PARITY=0 ... ... @@ -346,11 +346,11 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width: 120px" %)(((349 +|(% style="width:80px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) 353 -)))|(% style="width:1 90px" %)(((353 +)))|(% style="width:210px" %)((( 354 354 ((( 355 355 ((( 356 356 Set serial stopbit (for RS485 connection) ... ... @@ -362,7 +362,7 @@ 362 362 Default Value is: 1bit. 363 363 ))) 364 364 ))) 365 -)))|(% style="width:1 90px" %)(((365 +)))|(% style="width:210px" %)((( 366 366 ((( 367 367 ((( 368 368 AT+STOPBIT=0 for 1bit ... ... @@ -382,8 +382,6 @@ 382 382 ))) 383 383 ))) 384 384 385 - 386 - 387 387 === 3.3.2 Configure sensors === 388 388 389 389 ((( ... ... @@ -395,14 +395,14 @@ 395 395 ))) 396 396 397 397 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 398 -|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**399 -|AT+CFGDEV|(% style="width: 120px" %)(((396 +|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 397 +|AT+CFGDEV|(% style="width:80px" %)((( 400 400 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 401 401 402 402 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 403 403 404 404 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 405 -)))|(% style="width:1 90px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m403 +)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 406 406 407 407 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 408 408 ... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - {{{}}}}873 +} 876 876 877 877 878 878 ))) ... ... @@ -902,8 +902,6 @@ 902 902 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 903 903 ))) 904 904 905 - 906 - 907 907 === 3.5.1 Common Commands: === 908 908 909 909 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1362,26 +1362,49 @@ 1362 1362 1363 1363 ==== **Clear RS485 Command** ==== 1364 1364 1361 +((( 1365 1365 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1363 +))) 1366 1366 1365 +((( 1366 + 1367 +))) 1367 1367 1368 -* **AT Command:** 1369 +* ((( 1370 +**AT Command:** 1371 +))) 1369 1369 1370 1370 ((( 1371 1371 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1372 1372 ))) 1373 1373 1377 +((( 1374 1374 Example screen shot after clear all RS485 commands. 1379 +))) 1375 1375 1381 +((( 1382 + 1383 +))) 1376 1376 1385 +((( 1377 1377 The uplink screen shot is: 1387 +))) 1378 1378 1389 +((( 1379 1379 [[image:1654134704555-320.png]] 1391 +))) 1380 1380 1393 +((( 1394 + 1395 +))) 1381 1381 1382 -* **Downlink Payload:** 1397 +* ((( 1398 +**Downlink Payload:** 1399 +))) 1383 1383 1401 +((( 1384 1384 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1403 +))) 1385 1385 1386 1386 1387 1387 ... ... @@ -1388,44 +1388,77 @@ 1388 1388 1389 1389 ==== **Set Serial Communication Parameters** ==== 1390 1390 1410 +((( 1391 1391 Set the Rs485 serial communication parameters: 1412 +))) 1392 1392 1393 -* **AT Command:** 1414 +* ((( 1415 +**AT Command:** 1416 +))) 1394 1394 1418 +((( 1395 1395 Set Baud Rate: 1420 +))) 1396 1396 1397 1397 (% class="box infomessage" %) 1398 1398 ((( 1424 +((( 1399 1399 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1400 1400 ))) 1427 +))) 1401 1401 1429 +((( 1402 1402 Set UART Parity 1431 +))) 1403 1403 1404 1404 (% class="box infomessage" %) 1405 1405 ((( 1435 +((( 1406 1406 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1407 1407 ))) 1438 +))) 1408 1408 1440 +((( 1409 1409 Set STOPBIT 1442 +))) 1410 1410 1411 1411 (% class="box infomessage" %) 1412 1412 ((( 1446 +((( 1413 1413 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1414 1414 ))) 1449 +))) 1415 1415 1451 +((( 1452 + 1453 +))) 1416 1416 1417 -* **Downlink Payload:** 1455 +* ((( 1456 +**Downlink Payload:** 1457 +))) 1418 1418 1459 +((( 1419 1419 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1461 +))) 1420 1420 1463 +((( 1421 1421 **Example:** 1465 +))) 1422 1422 1423 -* A7 01 00 60 same as AT+BAUDR=9600 1424 -* A7 01 04 80 same as AT+BAUDR=115200 1467 +* ((( 1468 +A7 01 00 60 same as AT+BAUDR=9600 1469 +))) 1470 +* ((( 1471 +A7 01 04 80 same as AT+BAUDR=115200 1472 +))) 1425 1425 1474 +((( 1426 1426 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1476 +))) 1427 1427 1478 +((( 1428 1428 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1480 +))) 1429 1429 1430 1430 1431 1431 ... ... @@ -1432,22 +1432,41 @@ 1432 1432 1433 1433 ==== **Control output power duration** ==== 1434 1434 1487 +((( 1435 1435 User can set the output power duration before each sampling. 1489 +))) 1436 1436 1437 -* **AT Command:** 1491 +* ((( 1492 +**AT Command:** 1493 +))) 1438 1438 1495 +((( 1439 1439 **Example:** 1497 +))) 1440 1440 1499 +((( 1441 1441 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1501 +))) 1442 1442 1503 +((( 1443 1443 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1505 +))) 1444 1444 1507 +((( 1508 + 1509 +))) 1445 1445 1446 -* **LoRaWAN Downlink Command:** 1511 +* ((( 1512 +**LoRaWAN Downlink Command:** 1513 +))) 1447 1447 1515 +((( 1448 1448 **07 01 aa bb** Same as AT+5VT=(aa bb) 1517 +))) 1449 1449 1519 +((( 1450 1450 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1521 +))) 1451 1451 1452 1452 1453 1453 ... ... @@ -1457,8 +1457,6 @@ 1457 1457 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1458 1458 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1459 1459 1460 - 1461 - 1462 1462 == 3.7 +3V3 Output == 1463 1463 1464 1464 ((( ... ... @@ -1536,8 +1536,6 @@ 1536 1536 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1537 1537 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1538 1538 1539 - 1540 - 1541 1541 == 3.10 Switch Jumper == 1542 1542 1543 1543 (% border="1" style="background-color:#ffffcc; color:green; width:515px" %) ... ... @@ -1749,8 +1749,6 @@ 1749 1749 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1750 1750 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1751 1751 1752 - 1753 - 1754 1754 = 9. Packing Info = 1755 1755 1756 1756 (((