Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1244,60 +1244,32 @@ 1244 1244 1245 1245 ==== **RS485 command timeout** ==== 1246 1246 1247 -((( 1248 1248 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 1249 -))) 1250 1250 1251 -((( 1252 1252 Default value: 0, range: 0 ~~ 5 seconds 1253 -))) 1254 1254 1255 -((( 1256 - 1257 -))) 1258 1258 1259 -* ((( 1260 -**AT Command:** 1261 -))) 1252 +* **AT Command:** 1262 1262 1263 1263 (% class="box infomessage" %) 1264 1264 ((( 1265 -((( 1266 1266 **AT+CMDDLaa=hex(bb cc)** 1267 1267 ))) 1268 -))) 1269 1269 1270 -((( 1271 1271 **Example:** 1272 -))) 1273 1273 1274 -((( 1275 1275 **AT+CMDDL1=1000** to send the open time to 1000ms 1276 -))) 1277 1277 1278 -((( 1279 - 1280 -))) 1281 1281 1282 -* ((( 1283 -**Downlink Payload:** 1284 -))) 1264 +* **Downlink Payload:** 1285 1285 1286 -((( 1287 1287 0x AA aa bb cc 1288 -))) 1289 1289 1290 -((( 1291 1291 Same as: AT+CMDDLaa=hex(bb cc) 1292 -))) 1293 1293 1294 -((( 1295 1295 **Example:** 1296 -))) 1297 1297 1298 -((( 1299 1299 **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 1300 -))) 1301 1301 1302 1302 1303 1303