Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -283,28 +283,28 @@ 283 283 ))) 284 284 285 285 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 286 -|=(% style="width: 120px;" %)(((286 +|=(% style="width: 80px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) 290 -)))|=(% style="width: 1 90px;" %)(((290 +)))|=(% style="width: 210px;" %)((( 291 291 ((( 292 292 **Description** 293 293 ))) 294 -)))|=(% style="width: 1 90px;" %)(((294 +)))|=(% style="width: 210px;" %)((( 295 295 ((( 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width: 120px" %)(((299 +|(% style="width:80px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) 303 -)))|(% style="width:1 90px" %)(((303 +)))|(% style="width:210px" %)((( 304 304 ((( 305 305 Set the baud rate (for RS485 connection). Default Value is: 9600. 306 306 ))) 307 -)))|(% style="width:1 90px" %)(((307 +)))|(% style="width:210px" %)((( 308 308 ((( 309 309 ((( 310 310 AT+BAUDR=9600 ... ... @@ -317,11 +317,11 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width: 120px" %)(((320 +|(% style="width:80px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) 324 -)))|(% style="width:1 90px" %)(((324 +)))|(% style="width:210px" %)((( 325 325 ((( 326 326 ((( 327 327 Set UART parity (for RS485 connection) ... ... @@ -333,7 +333,7 @@ 333 333 Default Value is: no parity. 334 334 ))) 335 335 ))) 336 -)))|(% style="width:1 90px" %)(((336 +)))|(% style="width:210px" %)((( 337 337 ((( 338 338 ((( 339 339 AT+PARITY=0 ... ... @@ -346,11 +346,11 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width: 120px" %)(((349 +|(% style="width:80px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) 353 -)))|(% style="width:1 90px" %)(((353 +)))|(% style="width:210px" %)((( 354 354 ((( 355 355 ((( 356 356 Set serial stopbit (for RS485 connection) ... ... @@ -362,7 +362,7 @@ 362 362 Default Value is: 1bit. 363 363 ))) 364 364 ))) 365 -)))|(% style="width:1 90px" %)(((365 +)))|(% style="width:210px" %)((( 366 366 ((( 367 367 ((( 368 368 AT+STOPBIT=0 for 1bit ... ... @@ -383,7 +383,6 @@ 383 383 ))) 384 384 385 385 386 - 387 387 === 3.3.2 Configure sensors === 388 388 389 389 ((( ... ... @@ -395,14 +395,14 @@ 395 395 ))) 396 396 397 397 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 398 -|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**399 -|AT+CFGDEV|(% style="width: 120px" %)(((397 +|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 398 +|AT+CFGDEV|(% style="width:80px" %)((( 400 400 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 401 401 402 402 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 403 403 404 404 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 405 -)))|(% style="width:1 90px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m404 +)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 406 406 407 407 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 408 408 ... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - {{{}}}}874 +} 876 876 877 877 878 878 ))) ... ... @@ -903,7 +903,6 @@ 903 903 ))) 904 904 905 905 906 - 907 907 === 3.5.1 Common Commands: === 908 908 909 909 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1231,9 +1231,13 @@ 1231 1231 [[image:1654133954153-643.png]] 1232 1232 1233 1233 1234 -* **Downlink Commands:** 1232 +* ((( 1233 +**Downlink Commands:** 1234 +))) 1235 1235 1236 +((( 1236 1236 **A9 aa** ~-~-> Same as AT+MBFUN=aa 1238 +))) 1237 1237 1238 1238 1239 1239 ... ... @@ -1240,32 +1240,60 @@ 1240 1240 1241 1241 ==== **RS485 command timeout** ==== 1242 1242 1245 +((( 1243 1243 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 1247 +))) 1244 1244 1249 +((( 1245 1245 Default value: 0, range: 0 ~~ 5 seconds 1251 +))) 1246 1246 1253 +((( 1254 + 1255 +))) 1247 1247 1248 -* **AT Command:** 1257 +* ((( 1258 +**AT Command:** 1259 +))) 1249 1249 1250 1250 (% class="box infomessage" %) 1251 1251 ((( 1263 +((( 1252 1252 **AT+CMDDLaa=hex(bb cc)** 1253 1253 ))) 1266 +))) 1254 1254 1268 +((( 1255 1255 **Example:** 1270 +))) 1256 1256 1272 +((( 1257 1257 **AT+CMDDL1=1000** to send the open time to 1000ms 1274 +))) 1258 1258 1276 +((( 1277 + 1278 +))) 1259 1259 1260 -* **Downlink Payload:** 1280 +* ((( 1281 +**Downlink Payload:** 1282 +))) 1261 1261 1284 +((( 1262 1262 0x AA aa bb cc 1286 +))) 1263 1263 1288 +((( 1264 1264 Same as: AT+CMDDLaa=hex(bb cc) 1290 +))) 1265 1265 1292 +((( 1266 1266 **Example:** 1294 +))) 1267 1267 1296 +((( 1268 1268 **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 1298 +))) 1269 1269 1270 1270 1271 1271 ... ... @@ -1272,28 +1272,47 @@ 1272 1272 1273 1273 ==== **Uplink payload mode** ==== 1274 1274 1305 +((( 1275 1275 Define to use one uplink or multiple uplinks for the sampling. 1307 +))) 1276 1276 1309 +((( 1277 1277 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 1311 +))) 1278 1278 1279 -* **AT Command:** 1313 +* ((( 1314 +**AT Command:** 1315 +))) 1280 1280 1281 1281 (% class="box infomessage" %) 1282 1282 ((( 1319 +((( 1283 1283 **AT+DATAUP=0** 1284 1284 ))) 1322 +))) 1285 1285 1286 1286 (% class="box infomessage" %) 1287 1287 ((( 1326 +((( 1288 1288 **AT+DATAUP=1** 1289 1289 ))) 1329 +))) 1290 1290 1331 +((( 1332 + 1333 +))) 1291 1291 1292 -* **Downlink Payload:** 1335 +* ((( 1336 +**Downlink Payload:** 1337 +))) 1293 1293 1339 +((( 1294 1294 **0xAD 00** **~-~->** Same as AT+DATAUP=0 1341 +))) 1295 1295 1343 +((( 1296 1296 **0xAD 01** **~-~->** Same as AT+DATAUP=1 1345 +))) 1297 1297 1298 1298 1299 1299 ... ... @@ -1311,26 +1311,49 @@ 1311 1311 1312 1312 ==== **Clear RS485 Command** ==== 1313 1313 1363 +((( 1314 1314 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1365 +))) 1315 1315 1367 +((( 1368 + 1369 +))) 1316 1316 1317 -* **AT Command:** 1371 +* ((( 1372 +**AT Command:** 1373 +))) 1318 1318 1319 1319 ((( 1320 1320 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1321 1321 ))) 1322 1322 1379 +((( 1323 1323 Example screen shot after clear all RS485 commands. 1381 +))) 1324 1324 1383 +((( 1384 + 1385 +))) 1325 1325 1387 +((( 1326 1326 The uplink screen shot is: 1389 +))) 1327 1327 1391 +((( 1328 1328 [[image:1654134704555-320.png]] 1393 +))) 1329 1329 1395 +((( 1396 + 1397 +))) 1330 1330 1331 -* **Downlink Payload:** 1399 +* ((( 1400 +**Downlink Payload:** 1401 +))) 1332 1332 1403 +((( 1333 1333 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1405 +))) 1334 1334 1335 1335 1336 1336 ... ... @@ -1337,44 +1337,77 @@ 1337 1337 1338 1338 ==== **Set Serial Communication Parameters** ==== 1339 1339 1412 +((( 1340 1340 Set the Rs485 serial communication parameters: 1414 +))) 1341 1341 1342 -* **AT Command:** 1416 +* ((( 1417 +**AT Command:** 1418 +))) 1343 1343 1420 +((( 1344 1344 Set Baud Rate: 1422 +))) 1345 1345 1346 1346 (% class="box infomessage" %) 1347 1347 ((( 1426 +((( 1348 1348 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1349 1349 ))) 1429 +))) 1350 1350 1431 +((( 1351 1351 Set UART Parity 1433 +))) 1352 1352 1353 1353 (% class="box infomessage" %) 1354 1354 ((( 1437 +((( 1355 1355 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1356 1356 ))) 1440 +))) 1357 1357 1442 +((( 1358 1358 Set STOPBIT 1444 +))) 1359 1359 1360 1360 (% class="box infomessage" %) 1361 1361 ((( 1448 +((( 1362 1362 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1363 1363 ))) 1451 +))) 1364 1364 1453 +((( 1454 + 1455 +))) 1365 1365 1366 -* **Downlink Payload:** 1457 +* ((( 1458 +**Downlink Payload:** 1459 +))) 1367 1367 1461 +((( 1368 1368 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1463 +))) 1369 1369 1465 +((( 1370 1370 **Example:** 1467 +))) 1371 1371 1372 -* A7 01 00 60 same as AT+BAUDR=9600 1373 -* A7 01 04 80 same as AT+BAUDR=115200 1469 +* ((( 1470 +A7 01 00 60 same as AT+BAUDR=9600 1471 +))) 1472 +* ((( 1473 +A7 01 04 80 same as AT+BAUDR=115200 1474 +))) 1374 1374 1476 +((( 1375 1375 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1478 +))) 1376 1376 1480 +((( 1377 1377 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1482 +))) 1378 1378 1379 1379 1380 1380 ... ... @@ -1381,22 +1381,41 @@ 1381 1381 1382 1382 ==== **Control output power duration** ==== 1383 1383 1489 +((( 1384 1384 User can set the output power duration before each sampling. 1491 +))) 1385 1385 1386 -* **AT Command:** 1493 +* ((( 1494 +**AT Command:** 1495 +))) 1387 1387 1497 +((( 1388 1388 **Example:** 1499 +))) 1389 1389 1501 +((( 1390 1390 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1503 +))) 1391 1391 1505 +((( 1392 1392 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1507 +))) 1393 1393 1509 +((( 1510 + 1511 +))) 1394 1394 1395 -* **LoRaWAN Downlink Command:** 1513 +* ((( 1514 +**LoRaWAN Downlink Command:** 1515 +))) 1396 1396 1517 +((( 1397 1397 **07 01 aa bb** Same as AT+5VT=(aa bb) 1519 +))) 1398 1398 1521 +((( 1399 1399 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1523 +))) 1400 1400 1401 1401 1402 1402 ... ... @@ -1407,7 +1407,6 @@ 1407 1407 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1408 1408 1409 1409 1410 - 1411 1411 == 3.7 +3V3 Output == 1412 1412 1413 1413 ((( ... ... @@ -1486,7 +1486,6 @@ 1486 1486 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1487 1487 1488 1488 1489 - 1490 1490 == 3.10 Switch Jumper == 1491 1491 1492 1492 (% border="1" style="background-color:#ffffcc; color:green; width:515px" %) ... ... @@ -1699,7 +1699,6 @@ 1699 1699 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1700 1700 1701 1701 1702 - 1703 1703 = 9. Packing Info = 1704 1704 1705 1705 (((