... ... @@ -872,7 +872,7 @@
872 872  )))
873 873  
874 874  (((
875 -{{{}}}}
875 +**}**
876 876  
877 877  
878 878  )))
... ... @@ -939,101 +939,53 @@
939 939  
940 940  ==== **RS485 Debug Command (AT+CFGDEV)** ====
941 941  
942 -(((
943 943  This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling.
944 -)))
945 945  
946 -* (((
947 -**AT Command**
948 -)))
944 +* **AT Command**
949 949  
950 950  (% class="box infomessage" %)
951 951  (((
952 -(((
953 953  **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m**
954 954  )))
955 -)))
956 956  
957 -(((
958 958  m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command.
959 -)))
960 960  
961 -(((
962 -
963 -)))
964 964  
965 -* (((
966 -**Downlink Payload**
967 -)))
954 +* **Downlink Payload**
968 968  
969 -(((
970 970  Format: A8 MM NN XX XX XX XX YY
971 -)))
972 972  
973 -(((
974 974  Where:
975 -)))
976 976  
977 -* (((
978 -MM: 1: add CRC-16/MODBUS ; 0: no CRC
979 -)))
980 -* (((
981 -NN: The length of RS485 command
982 -)))
983 -* (((
984 -XX XX XX XX: RS485 command total NN bytes
985 -)))
986 -* (((
987 -YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
988 -)))
960 +* MM: 1: add CRC-16/MODBUS ; 0: no CRC
961 +* NN: The length of RS485 command
962 +* XX XX XX XX: RS485 command total NN bytes
963 +* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command
989 989  
990 -(((
991 991  **Example 1:**
992 -)))
993 993  
994 -(((
995 995  To connect a Modbus Alarm with below commands.
996 -)))
997 997  
998 -* (((
999 -The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
1000 -)))
969 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually.
1001 1001  
1002 -* (((
1003 -The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
1004 -)))
971 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually.
1005 1005  
1006 -(((
1007 1007  So if user want to use downlink command to control to RS485 Alarm, he can use:
1008 -)))
1009 1009  
1010 -(((
1011 1011  (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm
1012 -)))
1013 1013  
1014 -(((
1015 1015  (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
1016 -)))
1017 1017  
1018 1018  (((
1019 1019  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
1020 1020  )))
1021 1021  
1022 -(((
1023 -
1024 -)))
1025 1025  
1026 -(((
1027 1027  **Example 2:**
1028 -)))
1029 1029  
1030 -(((
1031 1031  Check TTL Sensor return:
1032 -)))
1033 1033  
1034 -(((
1035 1035  [[image:1654132684752-193.png]]
1036 -)))
1037 1037  
1038 1038  
1039 1039  
... ... @@ -1062,121 +1062,62 @@
1062 1062  
1063 1063  ==== **Set RS485 Sampling Commands** ====
1064 1064  
1065 -(((
1066 1066  AT+COMMANDx, AT+DATACUTx and AT+SEARCHx
1067 -)))
1068 1068  
1069 -(((
1070 1070  These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]].
1071 -)))
1072 1072  
1073 -(((
1074 -
1075 -)))
1076 1076  
1077 -* (((
1078 -**AT Command:**
1079 -)))
1022 +* **AT Command:**
1080 1080  
1081 1081  (% class="box infomessage" %)
1082 1082  (((
1083 -(((
1084 1084  **AT+COMMANDx: Configure RS485 read command to sensor.**
1085 1085  )))
1086 -)))
1087 1087  
1088 1088  (% class="box infomessage" %)
1089 1089  (((
1090 -(((
1091 1091  **AT+DATACUTx: Configure how to handle return from RS485 devices.**
1092 1092  )))
1093 -)))
1094 1094  
1095 1095  (% class="box infomessage" %)
1096 1096  (((
1097 -(((
1098 1098  **AT+SEARCHx: Configure search command**
1099 1099  )))
1100 -)))
1101 1101  
1102 -(((
1103 -
1104 -)))
1105 1105  
1106 -* (((
1107 -**Downlink Payload:**
1108 -)))
1040 +* **Downlink Payload:**
1109 1109  
1110 -(((
1111 1111  **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx.
1112 -)))
1113 1113  
1114 -(((
1115 1115  (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink.
1116 -)))
1117 1117  
1118 -(((
1119 1119  Format: AF MM NN LL XX XX XX XX YY
1120 -)))
1121 1121  
1122 -(((
1123 1123  Where:
1124 -)))
1125 1125  
1126 -* (((
1127 -MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
1128 -)))
1129 -* (((
1130 -NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
1131 -)))
1132 -* (((
1133 -LL:  The length of AT+COMMAND or AT+DATACUT command
1134 -)))
1135 -* (((
1136 -XX XX XX XX: AT+COMMAND or AT+DATACUT command
1137 -)))
1138 -* (((
1139 -YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
1140 -)))
1050 +* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F,
1051 +* NN:  0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value.
1052 +* LL:  The length of AT+COMMAND or AT+DATACUT command
1053 +* XX XX XX XX: AT+COMMAND or AT+DATACUT command
1054 +* YY:  If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command.
1141 1141  
1142 -(((
1143 1143  **Example:**
1144 -)))
1145 1145  
1146 -(((
1147 1147  (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1
1148 -)))
1149 1149  
1150 -(((
1151 1151  (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10**
1152 -)))
1153 1153  
1154 -(((
1155 1155  (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10**
1156 -)))
1157 1157  
1158 -(((
1159 -
1160 -)))
1161 1161  
1162 -(((
1163 1163  **0xAB** downlink command can be used for set AT+SEARCHx
1164 -)))
1165 1165  
1166 -(((
1167 1167  **Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So
1168 -)))
1169 1169  
1170 -* (((
1171 -AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
1172 -)))
1173 -* (((
1174 -AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
1175 -)))
1069 +* AB aa 01 03 xx xx xx  same as AT+SEARCHaa=1,xx xx xx
1070 +* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands
1176 1176  
1177 -(((
1178 1178  **AB aa 02 03 xx xx xx 02 yy yy**  same as **AT+SEARCHaa=2,xx xx xx+yy yy**
1179 -)))
1180 1180  
1181 1181  
1182 1182  
... ... @@ -1183,47 +1183,24 @@
1183 1183  
1184 1184  ==== **Fast command to handle MODBUS device** ====
1185 1185  
1186 -(((
1187 1187  AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]].
1188 -)))
1189 1189  
1190 -(((
1191 1191  This command is valid since v1.3 firmware version
1192 -)))
1193 1193  
1194 -(((
1195 -
1196 -)))
1197 1197  
1198 -(((
1199 1199  **AT+MBFUN has only two value:**
1200 -)))
1201 1201  
1202 -* (((
1203 -**AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return
1204 -)))
1086 +* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return
1205 1205  
1206 -(((
1207 1207  AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore.
1208 -)))
1209 1209  
1210 -* (((
1211 -**AT+MBFUN=0**: Disable Modbus fast reading.
1212 -)))
1090 +* **AT+MBFUN=0**: Disable Modbus fast reading.
1213 1213  
1214 -(((
1215 1215  **Example:**
1216 -)))
1217 1217  
1218 -* (((
1219 -AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
1220 -)))
1221 -* (((
1222 -AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
1223 -)))
1224 -* (((
1225 -AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
1226 -)))
1094 +* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0).
1095 +* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08.
1096 +* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10.
1227 1227  
1228 1228  [[image:1654133913295-597.png]]
1229 1229