Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
From version 41.34
edited by Xiaoling
on 2022/06/06 11:19
on 2022/06/06 11:19
Change comment:
There is no comment for this version
To version 43.1
edited by Edwin Chen
on 2022/06/13 10:47
on 2022/06/13 10:47
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -94,6 +94,7 @@ 94 94 * 127 dB Dynamic Range RSSI. 95 95 * Automatic RF Sense and CAD with ultra-fast AFC. 96 96 97 + 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN Class A & Class C protocol (default Class A) ... ... @@ -105,6 +105,7 @@ 105 105 * Support Modbus protocol 106 106 * Support Interrupt uplink 107 107 109 + 108 108 == 1.4 Applications == 109 109 110 110 * Smart Buildings & Home Automation ... ... @@ -114,6 +114,7 @@ 114 114 * Smart Cities 115 115 * Smart Factory 116 116 119 + 117 117 == 1.5 Firmware Change log == 118 118 119 119 [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]] ... ... @@ -283,28 +283,28 @@ 283 283 ))) 284 284 285 285 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 286 -|=(% style="width: 120px;" %)(((289 +|=(% style="width: 80px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) 290 -)))|=(% style="width: 1 90px;" %)(((293 +)))|=(% style="width: 210px;" %)((( 291 291 ((( 292 292 **Description** 293 293 ))) 294 -)))|=(% style="width: 1 90px;" %)(((297 +)))|=(% style="width: 210px;" %)((( 295 295 ((( 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width: 120px" %)(((302 +|(% style="width:80px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) 303 -)))|(% style="width:1 90px" %)(((306 +)))|(% style="width:210px" %)((( 304 304 ((( 305 305 Set the baud rate (for RS485 connection). Default Value is: 9600. 306 306 ))) 307 -)))|(% style="width:1 90px" %)(((310 +)))|(% style="width:210px" %)((( 308 308 ((( 309 309 ((( 310 310 AT+BAUDR=9600 ... ... @@ -317,11 +317,11 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width: 120px" %)(((323 +|(% style="width:80px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) 324 -)))|(% style="width:1 90px" %)(((327 +)))|(% style="width:210px" %)((( 325 325 ((( 326 326 ((( 327 327 Set UART parity (for RS485 connection) ... ... @@ -333,7 +333,7 @@ 333 333 Default Value is: no parity. 334 334 ))) 335 335 ))) 336 -)))|(% style="width:1 90px" %)(((339 +)))|(% style="width:210px" %)((( 337 337 ((( 338 338 ((( 339 339 AT+PARITY=0 ... ... @@ -346,11 +346,11 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width: 120px" %)(((352 +|(% style="width:80px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) 353 -)))|(% style="width:1 90px" %)(((356 +)))|(% style="width:210px" %)((( 354 354 ((( 355 355 ((( 356 356 Set serial stopbit (for RS485 connection) ... ... @@ -362,7 +362,7 @@ 362 362 Default Value is: 1bit. 363 363 ))) 364 364 ))) 365 -)))|(% style="width:1 90px" %)(((368 +)))|(% style="width:210px" %)((( 366 366 ((( 367 367 ((( 368 368 AT+STOPBIT=0 for 1bit ... ... @@ -383,7 +383,6 @@ 383 383 ))) 384 384 385 385 386 - 387 387 === 3.3.2 Configure sensors === 388 388 389 389 ((( ... ... @@ -395,14 +395,20 @@ 395 395 ))) 396 396 397 397 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 398 -|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 399 -|AT+CFGDEV|(% style="width:120px" %)((( 400 +|=(% style="width: 80px;" %)**AT Commands**|=(% style="width: 210px;" %)**Description**|=(% style="width: 210px;" %)**Example** 401 +|AT+CFGDEV|(% style="width:80px" %)((( 402 +((( 400 400 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 404 +))) 401 401 406 +((( 402 402 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 408 +))) 403 403 410 +((( 404 404 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 405 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 412 +))) 413 +)))|(% style="width:210px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 406 406 407 407 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 408 408 ... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - {{{}}}}883 +**}** 876 876 877 877 878 878 ))) ... ... @@ -902,8 +902,6 @@ 902 902 (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 903 903 ))) 904 904 905 - 906 - 907 907 === 3.5.1 Common Commands: === 908 908 909 909 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -1183,24 +1183,47 @@ 1183 1183 1184 1184 ==== **Fast command to handle MODBUS device** ==== 1185 1185 1192 +((( 1186 1186 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. 1194 +))) 1187 1187 1196 +((( 1188 1188 This command is valid since v1.3 firmware version 1198 +))) 1189 1189 1200 +((( 1201 + 1202 +))) 1190 1190 1204 +((( 1191 1191 **AT+MBFUN has only two value:** 1206 +))) 1192 1192 1193 -* **AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 1208 +* ((( 1209 +**AT+MBFUN=1**: Enable Modbus reading. And get response base on the MODBUS return 1210 +))) 1194 1194 1212 +((( 1195 1195 AT+MBFUN=1, device can auto read the Modbus function code: 01, 02, 03 or 04. AT+MBFUN has lower priority vs AT+DATACUT command. If AT+DATACUT command is configured, AT+MBFUN will be ignore. 1214 +))) 1196 1196 1197 -* **AT+MBFUN=0**: Disable Modbus fast reading. 1216 +* ((( 1217 +**AT+MBFUN=0**: Disable Modbus fast reading. 1218 +))) 1198 1198 1220 +((( 1199 1199 **Example:** 1222 +))) 1200 1200 1201 -* AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 1202 -* AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 1203 -* AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 1224 +* ((( 1225 +AT+MBFUN=1 and AT+DATACUT1/AT+DATACUT2 are not configure (0,0,0). 1226 +))) 1227 +* ((( 1228 +AT+COMMAND1= 01 03 00 10 00 08,1 ~-~-> read slave address 01 , function code 03, start address 00 01, quantity of registers 00 08. 1229 +))) 1230 +* ((( 1231 +AT+COMMAND2= 01 02 00 40 00 10,1 ~-~-> read slave address 01 , function code 02, start address 00 40, quantity of inputs 00 10. 1232 +))) 1204 1204 1205 1205 [[image:1654133913295-597.png]] 1206 1206 ... ... @@ -1208,9 +1208,13 @@ 1208 1208 [[image:1654133954153-643.png]] 1209 1209 1210 1210 1211 -* **Downlink Commands:** 1240 +* ((( 1241 +**Downlink Commands:** 1242 +))) 1212 1212 1244 +((( 1213 1213 **A9 aa** ~-~-> Same as AT+MBFUN=aa 1246 +))) 1214 1214 1215 1215 1216 1216 ... ... @@ -1217,32 +1217,60 @@ 1217 1217 1218 1218 ==== **RS485 command timeout** ==== 1219 1219 1253 +((( 1220 1220 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. 1255 +))) 1221 1221 1257 +((( 1222 1222 Default value: 0, range: 0 ~~ 5 seconds 1259 +))) 1223 1223 1261 +((( 1262 + 1263 +))) 1224 1224 1225 -* **AT Command:** 1265 +* ((( 1266 +**AT Command:** 1267 +))) 1226 1226 1227 1227 (% class="box infomessage" %) 1228 1228 ((( 1271 +((( 1229 1229 **AT+CMDDLaa=hex(bb cc)** 1230 1230 ))) 1274 +))) 1231 1231 1276 +((( 1232 1232 **Example:** 1278 +))) 1233 1233 1280 +((( 1234 1234 **AT+CMDDL1=1000** to send the open time to 1000ms 1282 +))) 1235 1235 1284 +((( 1285 + 1286 +))) 1236 1236 1237 -* **Downlink Payload:** 1288 +* ((( 1289 +**Downlink Payload:** 1290 +))) 1238 1238 1292 +((( 1239 1239 0x AA aa bb cc 1294 +))) 1240 1240 1296 +((( 1241 1241 Same as: AT+CMDDLaa=hex(bb cc) 1298 +))) 1242 1242 1300 +((( 1243 1243 **Example:** 1302 +))) 1244 1244 1304 +((( 1245 1245 **0xAA 01 03 E8** ~-~-> Same as **AT+CMDDL1=1000 ms** 1306 +))) 1246 1246 1247 1247 1248 1248 ... ... @@ -1249,28 +1249,47 @@ 1249 1249 1250 1250 ==== **Uplink payload mode** ==== 1251 1251 1313 +((( 1252 1252 Define to use one uplink or multiple uplinks for the sampling. 1315 +))) 1253 1253 1317 +((( 1254 1254 The use of this command please see: [[Compose Uplink payload>>||anchor="H3.3.4Composetheuplinkpayload"]] 1319 +))) 1255 1255 1256 -* **AT Command:** 1321 +* ((( 1322 +**AT Command:** 1323 +))) 1257 1257 1258 1258 (% class="box infomessage" %) 1259 1259 ((( 1327 +((( 1260 1260 **AT+DATAUP=0** 1261 1261 ))) 1330 +))) 1262 1262 1263 1263 (% class="box infomessage" %) 1264 1264 ((( 1334 +((( 1265 1265 **AT+DATAUP=1** 1266 1266 ))) 1337 +))) 1267 1267 1339 +((( 1340 + 1341 +))) 1268 1268 1269 -* **Downlink Payload:** 1343 +* ((( 1344 +**Downlink Payload:** 1345 +))) 1270 1270 1347 +((( 1271 1271 **0xAD 00** **~-~->** Same as AT+DATAUP=0 1349 +))) 1272 1272 1351 +((( 1273 1273 **0xAD 01** **~-~->** Same as AT+DATAUP=1 1353 +))) 1274 1274 1275 1275 1276 1276 ... ... @@ -1288,26 +1288,49 @@ 1288 1288 1289 1289 ==== **Clear RS485 Command** ==== 1290 1290 1371 +((( 1291 1291 The AT+COMMANDx and AT+DATACUTx settings are stored in special location, user can use below command to clear them. 1373 +))) 1292 1292 1375 +((( 1376 + 1377 +))) 1293 1293 1294 -* **AT Command:** 1379 +* ((( 1380 +**AT Command:** 1381 +))) 1295 1295 1296 1296 ((( 1297 1297 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1298 1298 ))) 1299 1299 1387 +((( 1300 1300 Example screen shot after clear all RS485 commands. 1389 +))) 1301 1301 1391 +((( 1392 + 1393 +))) 1302 1302 1395 +((( 1303 1303 The uplink screen shot is: 1397 +))) 1304 1304 1399 +((( 1305 1305 [[image:1654134704555-320.png]] 1401 +))) 1306 1306 1403 +((( 1404 + 1405 +))) 1307 1307 1308 -* **Downlink Payload:** 1407 +* ((( 1408 +**Downlink Payload:** 1409 +))) 1309 1309 1411 +((( 1310 1310 **0x09 aa bb** same as AT+CMDEAR=aa,bb 1413 +))) 1311 1311 1312 1312 1313 1313 ... ... @@ -1314,44 +1314,59 @@ 1314 1314 1315 1315 ==== **Set Serial Communication Parameters** ==== 1316 1316 1420 +((( 1317 1317 Set the Rs485 serial communication parameters: 1422 +))) 1318 1318 1319 -* **AT Command:** 1424 +* ((( 1425 +**AT Command:** 1426 +))) 1320 1320 1428 +((( 1321 1321 Set Baud Rate: 1430 +))) 1322 1322 1323 1323 (% class="box infomessage" %) 1324 1324 ((( 1434 +((( 1325 1325 **AT+BAUDR=9600** ~/~/ Options: (1200,2400,4800,14400,19200,115200) 1326 -))) 1327 1327 1328 1328 Set UART Parity 1329 - 1330 -(% class="box infomessage" %) 1331 -((( 1332 1332 **AT+PARITY=0** ~/~/ Option: 0: no parity, 1: odd parity, 2: even parity 1333 -))) 1334 1334 1335 1335 Set STOPBIT 1336 1336 1337 -(% class="box infomessage" %) 1338 -((( 1339 1339 **AT+STOPBIT=0** ~/~/ Option: 0 for 1bit; 1 for 1.5 bit ; 2 for 2 bits 1340 1340 ))) 1444 +))) 1341 1341 1342 1342 1343 -* **Downlink Payload:** 1447 +* ((( 1448 +**Downlink Payload:** 1449 +))) 1344 1344 1451 +((( 1345 1345 **A7 01 aa bb**: Same AT+BAUDR=hex(aa bb)*100 1453 +))) 1346 1346 1455 +((( 1347 1347 **Example:** 1457 +))) 1348 1348 1349 -* A7 01 00 60 same as AT+BAUDR=9600 1350 -* A7 01 04 80 same as AT+BAUDR=115200 1459 +* ((( 1460 +A7 01 00 60 same as AT+BAUDR=9600 1461 +))) 1462 +* ((( 1463 +A7 01 04 80 same as AT+BAUDR=115200 1464 +))) 1351 1351 1466 +((( 1352 1352 A7 02 aa: Same as AT+PARITY=aa (aa value: 00 , 01 or 02) 1468 +))) 1353 1353 1470 +((( 1354 1354 A7 03 aa: Same as AT+STOPBIT=aa (aa value: 00 , 01 or 02) 1472 +))) 1355 1355 1356 1356 1357 1357 ... ... @@ -1358,22 +1358,41 @@ 1358 1358 1359 1359 ==== **Control output power duration** ==== 1360 1360 1479 +((( 1361 1361 User can set the output power duration before each sampling. 1481 +))) 1362 1362 1363 -* **AT Command:** 1483 +* ((( 1484 +**AT Command:** 1485 +))) 1364 1364 1487 +((( 1365 1365 **Example:** 1489 +))) 1366 1366 1491 +((( 1367 1367 **AT+3V3T=1000** ~/~/ 3V3 output power will open 1s before each sampling. 1493 +))) 1368 1368 1495 +((( 1369 1369 **AT+5VT=1000** ~/~/ +5V output power will open 1s before each sampling. 1497 +))) 1370 1370 1499 +((( 1500 + 1501 +))) 1371 1371 1372 -* **LoRaWAN Downlink Command:** 1503 +* ((( 1504 +**LoRaWAN Downlink Command:** 1505 +))) 1373 1373 1507 +((( 1374 1374 **07 01 aa bb** Same as AT+5VT=(aa bb) 1509 +))) 1375 1375 1511 +((( 1376 1376 **07 02 aa bb** Same as AT+3V3T=(aa bb) 1513 +))) 1377 1377 1378 1378 1379 1379 ... ... @@ -1383,8 +1383,6 @@ 1383 1383 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1384 1384 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1385 1385 1386 - 1387 - 1388 1388 == 3.7 +3V3 Output == 1389 1389 1390 1390 ((( ... ... @@ -1462,22 +1462,14 @@ 1462 1462 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1463 1463 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1464 1464 1465 - 1466 - 1467 1467 == 3.10 Switch Jumper == 1468 1468 1469 -(% border="1" style="background-color:#ffffcc; color:green; width:515px" %) 1470 -|=(% style="width: 124px;" %)**Switch Jumper**|=(% style="width: 388px;" %)**Feature** 1471 -|(% style="width:124px" %)**SW1**|(% style="width:388px" %)((( 1472 -ISP position: Upgrade firmware via UART 1473 - 1602 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:463px" %) 1603 +|=(% style="width: 123px;" %)**Switch Jumper**|=(% style="width: 336px;" %)**Feature** 1604 +|(% style="width:123px" %)**SW1**|(% style="width:336px" %)ISP position: Upgrade firmware via UART 1474 1474 Flash position: Configure device, check running status. 1475 -))) 1476 -|(% style="width:124px" %)**SW2**|(% style="width:388px" %)((( 1477 -5V position: set to compatible with 5v I/O. 1478 - 1606 +|(% style="width:123px" %)**SW2**|(% style="width:336px" %)5V position: set to compatible with 5v I/O. 1479 1479 3.3v position: set to compatible with 3.3v I/O., 1480 -))) 1481 1481 1482 1482 ((( 1483 1483 **+3.3V**: is always ON ... ... @@ -1675,8 +1675,6 @@ 1675 1675 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1676 1676 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1677 1677 1678 - 1679 - 1680 1680 = 9. Packing Info = 1681 1681 1682 1682 (((