Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - {{{}}}}875 +**}** 876 876 877 877 878 878 ))) ... ... @@ -939,101 +939,53 @@ 939 939 940 940 ==== **RS485 Debug Command (AT+CFGDEV)** ==== 941 941 942 -((( 943 943 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 944 -))) 945 945 946 -* ((( 947 -**AT Command** 948 -))) 944 +* **AT Command** 949 949 950 950 (% class="box infomessage" %) 951 951 ((( 952 -((( 953 953 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 954 954 ))) 955 -))) 956 956 957 -((( 958 958 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 959 -))) 960 960 961 -((( 962 - 963 -))) 964 964 965 -* ((( 966 -**Downlink Payload** 967 -))) 954 +* **Downlink Payload** 968 968 969 -((( 970 970 Format: A8 MM NN XX XX XX XX YY 971 -))) 972 972 973 -((( 974 974 Where: 975 -))) 976 976 977 -* ((( 978 -MM: 1: add CRC-16/MODBUS ; 0: no CRC 979 -))) 980 -* ((( 981 -NN: The length of RS485 command 982 -))) 983 -* ((( 984 -XX XX XX XX: RS485 command total NN bytes 985 -))) 986 -* ((( 987 -YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 988 -))) 960 +* MM: 1: add CRC-16/MODBUS ; 0: no CRC 961 +* NN: The length of RS485 command 962 +* XX XX XX XX: RS485 command total NN bytes 963 +* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 989 989 990 -((( 991 991 **Example 1:** 992 -))) 993 993 994 -((( 995 995 To connect a Modbus Alarm with below commands. 996 -))) 997 997 998 -* ((( 999 -The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1000 -))) 969 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1001 1001 1002 -* ((( 1003 -The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1004 -))) 971 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1005 1005 1006 -((( 1007 1007 So if user want to use downlink command to control to RS485 Alarm, he can use: 1008 -))) 1009 1009 1010 -((( 1011 1011 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 1012 -))) 1013 1013 1014 -((( 1015 1015 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 1016 -))) 1017 1017 1018 1018 ((( 1019 1019 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 1020 1020 ))) 1021 1021 1022 -((( 1023 - 1024 -))) 1025 1025 1026 -((( 1027 1027 **Example 2:** 1028 -))) 1029 1029 1030 -((( 1031 1031 Check TTL Sensor return: 1032 -))) 1033 1033 1034 -((( 1035 1035 [[image:1654132684752-193.png]] 1036 -))) 1037 1037 1038 1038 1039 1039 ... ... @@ -1534,23 +1534,13 @@ 1534 1534 1535 1535 == 6.1 How to upgrade the image? == 1536 1536 1537 -((( 1538 1538 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1539 -))) 1540 1540 1541 -* ((( 1542 -Support new features 1543 -))) 1544 -* ((( 1545 -For bug fix 1546 -))) 1547 -* ((( 1548 -Change LoRaWAN bands. 1549 -))) 1491 +* Support new features 1492 +* For bug fix 1493 +* Change LoRaWAN bands. 1550 1550 1551 -((( 1552 1552 Below shows the hardware connection for how to upload an image to RS485-BL: 1553 -))) 1554 1554 1555 1555 [[image:1654136646995-976.png]] 1556 1556 ... ... @@ -1616,8 +1616,6 @@ 1616 1616 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1617 1617 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1618 1618 1619 - 1620 - 1621 1621 = 9. Packing Info = 1622 1622 1623 1623 (((