Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - {{{}}}}875 +**}** 876 876 877 877 878 878 ))) ... ... @@ -939,101 +939,53 @@ 939 939 940 940 ==== **RS485 Debug Command (AT+CFGDEV)** ==== 941 941 942 -((( 943 943 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 944 -))) 945 945 946 -* ((( 947 -**AT Command** 948 -))) 944 +* **AT Command** 949 949 950 950 (% class="box infomessage" %) 951 951 ((( 952 -((( 953 953 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 954 954 ))) 955 -))) 956 956 957 -((( 958 958 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 959 -))) 960 960 961 -((( 962 - 963 -))) 964 964 965 -* ((( 966 -**Downlink Payload** 967 -))) 954 +* **Downlink Payload** 968 968 969 -((( 970 970 Format: A8 MM NN XX XX XX XX YY 971 -))) 972 972 973 -((( 974 974 Where: 975 -))) 976 976 977 -* ((( 978 -MM: 1: add CRC-16/MODBUS ; 0: no CRC 979 -))) 980 -* ((( 981 -NN: The length of RS485 command 982 -))) 983 -* ((( 984 -XX XX XX XX: RS485 command total NN bytes 985 -))) 986 -* ((( 987 -YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 988 -))) 960 +* MM: 1: add CRC-16/MODBUS ; 0: no CRC 961 +* NN: The length of RS485 command 962 +* XX XX XX XX: RS485 command total NN bytes 963 +* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 989 989 990 -((( 991 991 **Example 1:** 992 -))) 993 993 994 -((( 995 995 To connect a Modbus Alarm with below commands. 996 -))) 997 997 998 -* ((( 999 -The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1000 -))) 969 +* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1001 1001 1002 -* ((( 1003 -The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1004 -))) 971 +* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1005 1005 1006 -((( 1007 1007 So if user want to use downlink command to control to RS485 Alarm, he can use: 1008 -))) 1009 1009 1010 -((( 1011 1011 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 1012 -))) 1013 1013 1014 -((( 1015 1015 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 1016 -))) 1017 1017 1018 1018 ((( 1019 1019 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 1020 1020 ))) 1021 1021 1022 -((( 1023 - 1024 -))) 1025 1025 1026 -((( 1027 1027 **Example 2:** 1028 -))) 1029 1029 1030 -((( 1031 1031 Check TTL Sensor return: 1032 -))) 1033 1033 1034 -((( 1035 1035 [[image:1654132684752-193.png]] 1036 -))) 1037 1037 1038 1038 1039 1039 ... ... @@ -1452,9 +1452,7 @@ 1452 1452 [[image:1654136105500-922.png]] 1453 1453 1454 1454 1455 -((( 1456 1456 More detail AT Command manual can be found at [[AT Command Manual>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] 1457 -))) 1458 1458 1459 1459 1460 1460 == 5.2 Common AT Command Sequence == ... ... @@ -1479,9 +1479,7 @@ 1479 1479 ))) 1480 1480 1481 1481 1482 -((( 1483 1483 If device already joined network: 1484 -))) 1485 1485 1486 1486 (% class="box infomessage" %) 1487 1487 ((( ... ... @@ -1520,12 +1520,10 @@ 1520 1520 1521 1521 (% style="color:red" %)**Note:** 1522 1522 1523 -((( 1524 1524 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1525 1525 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1526 1526 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1527 1527 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1528 -))) 1529 1529 1530 1530 [[image:1654136435598-589.png]] 1531 1531 ... ... @@ -1534,23 +1534,13 @@ 1534 1534 1535 1535 == 6.1 How to upgrade the image? == 1536 1536 1537 -((( 1538 1538 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1539 -))) 1540 1540 1541 -* ((( 1542 -Support new features 1543 -))) 1544 -* ((( 1545 -For bug fix 1546 -))) 1547 -* ((( 1548 -Change LoRaWAN bands. 1549 -))) 1485 +* Support new features 1486 +* For bug fix 1487 +* Change LoRaWAN bands. 1550 1550 1551 -((( 1552 1552 Below shows the hardware connection for how to upload an image to RS485-BL: 1553 -))) 1554 1554 1555 1555 [[image:1654136646995-976.png]] 1556 1556 ... ... @@ -1616,8 +1616,6 @@ 1616 1616 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1617 1617 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1618 1618 1619 - 1620 - 1621 1621 = 9. Packing Info = 1622 1622 1623 1623 (((