Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -872,7 +872,7 @@ 872 872 ))) 873 873 874 874 ((( 875 - **}**875 +{{{}}}} 876 876 877 877 878 878 ))) ... ... @@ -939,53 +939,101 @@ 939 939 940 940 ==== **RS485 Debug Command (AT+CFGDEV)** ==== 941 941 942 +((( 942 942 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 944 +))) 943 943 944 -* **AT Command** 946 +* ((( 947 +**AT Command** 948 +))) 945 945 946 946 (% class="box infomessage" %) 947 947 ((( 952 +((( 948 948 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 949 949 ))) 955 +))) 950 950 957 +((( 951 951 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 959 +))) 952 952 961 +((( 962 + 963 +))) 953 953 954 -* **Downlink Payload** 965 +* ((( 966 +**Downlink Payload** 967 +))) 955 955 969 +((( 956 956 Format: A8 MM NN XX XX XX XX YY 971 +))) 957 957 973 +((( 958 958 Where: 975 +))) 959 959 960 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC 961 -* NN: The length of RS485 command 962 -* XX XX XX XX: RS485 command total NN bytes 963 -* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 977 +* ((( 978 +MM: 1: add CRC-16/MODBUS ; 0: no CRC 979 +))) 980 +* ((( 981 +NN: The length of RS485 command 982 +))) 983 +* ((( 984 +XX XX XX XX: RS485 command total NN bytes 985 +))) 986 +* ((( 987 +YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 988 +))) 964 964 990 +((( 965 965 **Example 1:** 992 +))) 966 966 994 +((( 967 967 To connect a Modbus Alarm with below commands. 996 +))) 968 968 969 -* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 998 +* ((( 999 +The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1000 +))) 970 970 971 -* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1002 +* ((( 1003 +The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1004 +))) 972 972 1006 +((( 973 973 So if user want to use downlink command to control to RS485 Alarm, he can use: 1008 +))) 974 974 1010 +((( 975 975 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 1012 +))) 976 976 1014 +((( 977 977 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 1016 +))) 978 978 979 979 ((( 980 980 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 981 981 ))) 982 982 1022 +((( 1023 + 1024 +))) 983 983 1026 +((( 984 984 **Example 2:** 1028 +))) 985 985 1030 +((( 986 986 Check TTL Sensor return: 1032 +))) 987 987 1034 +((( 988 988 [[image:1654132684752-193.png]] 1036 +))) 989 989 990 990 991 991 ... ... @@ -1486,13 +1486,23 @@ 1486 1486 1487 1487 == 6.1 How to upgrade the image? == 1488 1488 1537 +((( 1489 1489 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1539 +))) 1490 1490 1491 -* Support new features 1492 -* For bug fix 1493 -* Change LoRaWAN bands. 1541 +* ((( 1542 +Support new features 1543 +))) 1544 +* ((( 1545 +For bug fix 1546 +))) 1547 +* ((( 1548 +Change LoRaWAN bands. 1549 +))) 1494 1494 1551 +((( 1495 1495 Below shows the hardware connection for how to upload an image to RS485-BL: 1553 +))) 1496 1496 1497 1497 [[image:1654136646995-976.png]] 1498 1498 ... ... @@ -1558,6 +1558,8 @@ 1558 1558 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1559 1559 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1560 1560 1619 + 1620 + 1561 1561 = 9. Packing Info = 1562 1562 1563 1563 (((