Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1472,12 +1472,10 @@ 1472 1472 1473 1473 (% style="color:red" %)**Note:** 1474 1474 1475 -((( 1476 1476 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1477 1477 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1478 1478 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1479 1479 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1480 -))) 1481 1481 1482 1482 [[image:1654136435598-589.png]] 1483 1483