Last modified by Xiaoling on 2025/04/23 15:57

From version 41.22
edited by Xiaoling
on 2022/06/06 11:10
Change comment: There is no comment for this version
To version 41.8
edited by Xiaoling
on 2022/06/06 10:56
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -510,10 +510,6 @@
510 510  )))
511 511  
512 512  (((
513 -
514 -)))
515 -
516 -(((
517 517  **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
518 518  )))
519 519  
... ... @@ -886,21 +886,13 @@
886 886  
887 887  == 3.5 Configure RS485-BL via AT or Downlink ==
888 888  
889 -(((
890 890  User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands
891 -)))
892 892  
893 -(((
894 894  There are two kinds of Commands:
895 -)))
896 896  
897 -* (((
898 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
899 -)))
889 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
900 900  
901 -* (((
902 -(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
903 -)))
891 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
904 904  
905 905  
906 906  
... ... @@ -912,7 +912,6 @@
912 912  === 3.5.2 Sensor related commands: ===
913 913  
914 914  
915 -
916 916  ==== **Choose Device Type (RS485 or TTL)** ====
917 917  
918 918  RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect.
... ... @@ -976,9 +976,7 @@
976 976  
977 977  (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm
978 978  
979 -(((
980 980  A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output.
981 -)))
982 982  
983 983  
984 984  **Example 2:**
... ... @@ -1107,7 +1107,6 @@
1107 1107  
1108 1108  
1109 1109  
1110 -
1111 1111  ==== **RS485 command timeout** ====
1112 1112  
1113 1113  Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action.
... ... @@ -1139,7 +1139,6 @@
1139 1139  
1140 1140  
1141 1141  
1142 -
1143 1143  ==== **Uplink payload mode** ====
1144 1144  
1145 1145  Define to use one uplink or multiple uplinks for the sampling.
... ... @@ -1186,9 +1186,7 @@
1186 1186  
1187 1187  * **AT Command:**
1188 1188  
1189 -(((
1190 1190  (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10
1191 -)))
1192 1192  
1193 1193  Example screen shot after clear all RS485 commands. 
1194 1194  
... ... @@ -1204,7 +1204,6 @@
1204 1204  
1205 1205  
1206 1206  
1207 -
1208 1208  ==== **Set Serial Communication Parameters** ====
1209 1209  
1210 1210  Set the Rs485 serial communication parameters:
... ... @@ -1248,7 +1248,6 @@
1248 1248  
1249 1249  
1250 1250  
1251 -
1252 1252  ==== **Control output power duration** ====
1253 1253  
1254 1254  User can set the output power duration before each sampling.
... ... @@ -1272,80 +1272,42 @@
1272 1272  
1273 1273  == 3.6 Buttons ==
1274 1274  
1275 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:233px" %)
1254 +(% border="1" style="background-color:#ffffcc; color:green; width:233px" %)
1276 1276  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1277 1277  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1278 1278  
1279 -
1280 -
1281 1281  == 3.7 +3V3 Output ==
1282 1282  
1283 -(((
1284 1284  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
1285 -)))
1286 1286  
1287 -(((
1288 1288  The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
1289 -)))
1290 1290  
1291 -(((
1292 1292  The +3V3 output time can be controlled by AT Command.
1293 -)))
1294 1294  
1295 -(((
1296 -
1297 -)))
1298 1298  
1299 -(((
1300 1300  (% style="color:#037691" %)**AT+3V3T=1000**
1301 -)))
1302 1302  
1303 -(((
1304 -
1305 -)))
1306 1306  
1307 -(((
1308 1308  Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
1309 -)))
1310 1310  
1311 -(((
1312 1312  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1313 -)))
1314 1314  
1315 1315  
1316 1316  == 3.8 +5V Output ==
1317 1317  
1318 -(((
1319 1319  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
1320 -)))
1321 1321  
1322 -(((
1323 1323  The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 
1324 -)))
1325 1325  
1326 -(((
1327 1327  The 5V output time can be controlled by AT Command.
1328 -)))
1329 1329  
1330 -(((
1331 -
1332 -)))
1333 1333  
1334 -(((
1335 1335  (% style="color:#037691" %)**AT+5VT=1000**
1336 -)))
1337 1337  
1338 -(((
1339 -
1340 -)))
1341 1341  
1342 -(((
1343 1343  Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
1344 -)))
1345 1345  
1346 -(((
1347 1347  By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
1348 -)))
1349 1349  
1350 1350  
1351 1351  == 3.9 LEDs ==
... ... @@ -1354,8 +1354,6 @@
1354 1354  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1355 1355  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1356 1356  
1357 -
1358 -
1359 1359  == 3.10 Switch Jumper ==
1360 1360  
1361 1361  (% border="1" style="background-color:#ffffcc; color:green; width:515px" %)