Last modified by Xiaoling on 2025/04/23 15:57

From version 41.22
edited by Xiaoling
on 2022/06/06 11:10
Change comment: There is no comment for this version
To version 41.19
edited by Xiaoling
on 2022/06/06 11:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1272,7 +1272,7 @@
1272 1272  
1273 1273  == 3.6 Buttons ==
1274 1274  
1275 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:233px" %)
1275 +(% border="1" style="background-color:#ffffcc; color:green; width:233px" %)
1276 1276  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1277 1277  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1278 1278  
... ... @@ -1280,72 +1280,36 @@
1280 1280  
1281 1281  == 3.7 +3V3 Output ==
1282 1282  
1283 -(((
1284 1284  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
1285 -)))
1286 1286  
1287 -(((
1288 1288  The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 
1289 -)))
1290 1290  
1291 -(((
1292 1292  The +3V3 output time can be controlled by AT Command.
1293 -)))
1294 1294  
1295 -(((
1296 -
1297 -)))
1298 1298  
1299 -(((
1300 1300  (% style="color:#037691" %)**AT+3V3T=1000**
1301 -)))
1302 1302  
1303 -(((
1304 -
1305 -)))
1306 1306  
1307 -(((
1308 1308  Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors.
1309 -)))
1310 1310  
1311 -(((
1312 1312  By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time
1313 -)))
1314 1314  
1315 1315  
1316 1316  == 3.8 +5V Output ==
1317 1317  
1318 -(((
1319 1319  RS485-BL has a Controllable +5V output, user can use this output to power external sensor.
1320 -)))
1321 1321  
1322 -(((
1323 1323  The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 
1324 -)))
1325 1325  
1326 -(((
1327 1327  The 5V output time can be controlled by AT Command.
1328 -)))
1329 1329  
1330 -(((
1331 -
1332 -)))
1333 1333  
1334 -(((
1335 1335  (% style="color:#037691" %)**AT+5VT=1000**
1336 -)))
1337 1337  
1338 -(((
1339 -
1340 -)))
1341 1341  
1342 -(((
1343 1343  Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors.
1344 -)))
1345 1345  
1346 -(((
1347 1347  By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor.
1348 -)))
1349 1349  
1350 1350  
1351 1351  == 3.9 LEDs ==
... ... @@ -1354,8 +1354,6 @@
1354 1354  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1355 1355  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1356 1356  
1357 -
1358 -
1359 1359  == 3.10 Switch Jumper ==
1360 1360  
1361 1361  (% border="1" style="background-color:#ffffcc; color:green; width:515px" %)