Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1280,38 +1280,75 @@ 1280 1280 1281 1281 == 3.7 +3V3 Output == 1282 1282 1283 +((( 1283 1283 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. 1285 +))) 1284 1284 1287 +((( 1285 1285 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 1289 +))) 1286 1286 1291 +((( 1287 1287 The +3V3 output time can be controlled by AT Command. 1293 +))) 1288 1288 1295 +((( 1296 + 1297 +))) 1289 1289 1299 +((( 1290 1290 (% style="color:#037691" %)**AT+3V3T=1000** 1301 +))) 1291 1291 1303 +((( 1304 + 1305 +))) 1292 1292 1307 +((( 1293 1293 Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors. 1309 +))) 1294 1294 1311 +((( 1295 1295 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1313 +))) 1296 1296 1297 1297 1298 1298 == 3.8 +5V Output == 1299 1299 1318 +((( 1300 1300 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. 1320 +))) 1301 1301 1322 +((( 1302 1302 The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 1324 +))) 1303 1303 1326 +((( 1304 1304 The 5V output time can be controlled by AT Command. 1328 +))) 1305 1305 1330 +((( 1331 + 1332 +))) 1306 1306 1334 +((( 1307 1307 (% style="color:#037691" %)**AT+5VT=1000** 1336 +))) 1308 1308 1338 +((( 1339 + 1340 +))) 1309 1309 1342 +((( 1310 1310 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors. 1344 +))) 1311 1311 1346 +((( 1312 1312 By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor. 1348 +))) 1313 1313 1314 1314 1351 + 1315 1315 == 3.9 LEDs == 1316 1316 1317 1317 (% border="1" style="background-color:#ffffcc; color:green; width:332px" %) ... ... @@ -1335,9 +1335,13 @@ 1335 1335 3.3v position: set to compatible with 3.3v I/O., 1336 1336 ))) 1337 1337 1375 +((( 1338 1338 **+3.3V**: is always ON 1377 +))) 1339 1339 1379 +((( 1340 1340 **+5V**: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1381 +))) 1341 1341 1342 1342 1343 1343 = 4. Case Study = ... ... @@ -1349,17 +1349,23 @@ 1349 1349 1350 1350 == 5.1 Access AT Command == 1351 1351 1393 +((( 1352 1352 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1395 +))) 1353 1353 1354 1354 [[image:1654135840598-282.png]] 1355 1355 1356 1356 1400 +((( 1357 1357 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1402 +))) 1358 1358 1359 1359 [[image:1654136105500-922.png]] 1360 1360 1361 1361 1407 +((( 1362 1362 More detail AT Command manual can be found at [[AT Command Manual>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] 1409 +))) 1363 1363 1364 1364 1365 1365 == 5.2 Common AT Command Sequence == ... ... @@ -1384,7 +1384,9 @@ 1384 1384 ))) 1385 1385 1386 1386 1434 +((( 1387 1387 If device already joined network: 1436 +))) 1388 1388 1389 1389 (% class="box infomessage" %) 1390 1390 ((( ... ... @@ -1423,10 +1423,12 @@ 1423 1423 1424 1424 (% style="color:red" %)**Note:** 1425 1425 1475 +((( 1426 1426 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1427 1427 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1428 1428 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1429 1429 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1480 +))) 1430 1430 1431 1431 [[image:1654136435598-589.png]] 1432 1432 ... ... @@ -1435,13 +1435,23 @@ 1435 1435 1436 1436 == 6.1 How to upgrade the image? == 1437 1437 1489 +((( 1438 1438 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1491 +))) 1439 1439 1440 -* Support new features 1441 -* For bug fix 1442 -* Change LoRaWAN bands. 1493 +* ((( 1494 +Support new features 1495 +))) 1496 +* ((( 1497 +For bug fix 1498 +))) 1499 +* ((( 1500 +Change LoRaWAN bands. 1501 +))) 1443 1443 1503 +((( 1444 1444 Below shows the hardware connection for how to upload an image to RS485-BL: 1505 +))) 1445 1445 1446 1446 [[image:1654136646995-976.png]] 1447 1447 ... ... @@ -1507,6 +1507,8 @@ 1507 1507 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1508 1508 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1509 1509 1571 + 1572 + 1510 1510 = 9. Packing Info = 1511 1511 1512 1512 (((