Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -510,6 +510,10 @@ 510 510 ))) 511 511 512 512 ((( 513 + 514 +))) 515 + 516 +((( 513 513 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 514 514 ))) 515 515 ... ... @@ -882,14 +882,24 @@ 882 882 883 883 == 3.5 Configure RS485-BL via AT or Downlink == 884 884 889 +((( 885 885 User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands 891 +))) 886 886 893 +((( 887 887 There are two kinds of Commands: 895 +))) 888 888 889 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 897 +* ((( 898 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 899 +))) 890 890 891 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 901 +* ((( 902 +(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 903 +))) 892 892 905 + 906 + 893 893 === 3.5.1 Common Commands: === 894 894 895 895 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -898,6 +898,7 @@ 898 898 === 3.5.2 Sensor related commands: === 899 899 900 900 915 + 901 901 ==== **Choose Device Type (RS485 or TTL)** ==== 902 902 903 903 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. ... ... @@ -921,6 +921,7 @@ 921 921 922 922 923 923 939 + 924 924 ==== **RS485 Debug Command (AT+CFGDEV)** ==== 925 925 926 926 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. ... ... @@ -972,6 +972,7 @@ 972 972 973 973 974 974 991 + 975 975 ==== **Set Payload version** ==== 976 976 977 977 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -992,6 +992,7 @@ 992 992 993 993 994 994 1012 + 995 995 ==== **Set RS485 Sampling Commands** ==== 996 996 997 997 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx ... ... @@ -1053,6 +1053,7 @@ 1053 1053 1054 1054 1055 1055 1074 + 1056 1056 ==== **Fast command to handle MODBUS device** ==== 1057 1057 1058 1058 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. ... ... @@ -1086,6 +1086,7 @@ 1086 1086 1087 1087 1088 1088 1108 + 1089 1089 ==== **RS485 command timeout** ==== 1090 1090 1091 1091 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. ... ... @@ -1117,6 +1117,7 @@ 1117 1117 1118 1118 1119 1119 1140 + 1120 1120 ==== **Uplink payload mode** ==== 1121 1121 1122 1122 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -1163,7 +1163,9 @@ 1163 1163 1164 1164 * **AT Command:** 1165 1165 1187 +((( 1166 1166 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1189 +))) 1167 1167 1168 1168 Example screen shot after clear all RS485 commands. 1169 1169 ... ... @@ -1179,6 +1179,7 @@ 1179 1179 1180 1180 1181 1181 1205 + 1182 1182 ==== **Set Serial Communication Parameters** ==== 1183 1183 1184 1184 Set the Rs485 serial communication parameters: ... ... @@ -1222,6 +1222,7 @@ 1222 1222 1223 1223 1224 1224 1249 + 1225 1225 ==== **Control output power duration** ==== 1226 1226 1227 1227 User can set the output power duration before each sampling. ... ... @@ -1249,6 +1249,8 @@ 1249 1249 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1250 1250 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1251 1251 1277 + 1278 + 1252 1252 == 3.7 +3V3 Output == 1253 1253 1254 1254 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.