Last modified by Xiaoling on 2025/04/23 15:57

From version 41.17
edited by Xiaoling
on 2022/06/06 11:05
Change comment: There is no comment for this version
To version 41.14
edited by Xiaoling
on 2022/06/06 10:58
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -510,10 +510,6 @@
510 510  )))
511 511  
512 512  (((
513 -
514 -)))
515 -
516 -(((
517 517  **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
518 518  )))
519 519  
... ... @@ -886,21 +886,13 @@
886 886  
887 887  == 3.5 Configure RS485-BL via AT or Downlink ==
888 888  
889 -(((
890 890  User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands
891 -)))
892 892  
893 -(((
894 894  There are two kinds of Commands:
895 -)))
896 896  
897 -* (((
898 -(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
899 -)))
889 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
900 900  
901 -* (((
902 -(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
903 -)))
891 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
904 904  
905 905  
906 906  
... ... @@ -1274,8 +1274,6 @@
1274 1274  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1275 1275  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1276 1276  
1277 -
1278 -
1279 1279  == 3.7 +3V3 Output ==
1280 1280  
1281 1281  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.