Last modified by Xiaoling on 2025/04/23 15:57

From version 41.14
edited by Xiaoling
on 2022/06/06 10:58
Change comment: There is no comment for this version
To version 41.17
edited by Xiaoling
on 2022/06/06 11:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -510,6 +510,10 @@
510 510  )))
511 511  
512 512  (((
513 +
514 +)))
515 +
516 +(((
513 513  **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
514 514  )))
515 515  
... ... @@ -882,13 +882,21 @@
882 882  
883 883  == 3.5 Configure RS485-BL via AT or Downlink ==
884 884  
889 +(((
885 885  User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands
891 +)))
886 886  
893 +(((
887 887  There are two kinds of Commands:
895 +)))
888 888  
889 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
897 +* (((
898 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
899 +)))
890 890  
891 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
901 +* (((
902 +(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
903 +)))
892 892  
893 893  
894 894  
... ... @@ -1262,6 +1262,8 @@
1262 1262  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1263 1263  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1264 1264  
1277 +
1278 +
1265 1265  == 3.7 +3V3 Output ==
1266 1266  
1267 1267  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.