... ... @@ -383,7 +383,6 @@
383 383  )))
384 384  
385 385  
386 -
387 387  === 3.3.2 Configure sensors ===
388 388  
389 389  (((
... ... @@ -407,7 +407,6 @@
407 407  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
408 408  
409 409  
410 -
411 411  === 3.3.3 Configure read commands for each sampling ===
412 412  
413 413  (((
... ... @@ -474,32 +474,20 @@
474 474  After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**.
475 475  )))
476 476  
477 -(((
478 478  **Examples:**
479 -)))
480 480  
481 -(((
482 482  Below are examples for the how above AT Commands works.
483 -)))
484 484  
485 -(((
486 486  **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
487 -)))
488 488  
489 489  (% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
490 490  |(% style="width:498px" %)(((
491 -(((
492 492  **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
493 -)))
494 494  
495 -(((
496 496  **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent**
497 -)))
498 498  
499 -(((
500 500  **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command**
501 501  )))
502 -)))
503 503  
504 504  For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually.
505 505  
... ... @@ -603,14 +603,10 @@
603 603  