... ... @@ -94,6 +94,7 @@
94 94  * 127 dB Dynamic Range RSSI.
95 95  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
96 96  
97 +
97 97  == 1.3 Features ==
98 98  
99 99  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -105,6 +105,7 @@
105 105  * Support Modbus protocol
106 106  * Support Interrupt uplink
107 107  
109 +
108 108  == 1.4 Applications ==
109 109  
110 110  * Smart Buildings & Home Automation
... ... @@ -114,6 +114,7 @@
114 114  * Smart Cities
115 115  * Smart Factory
116 116  
119 +
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -282,29 +282,29 @@
282 282  RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match.
283 283  )))
284 284  
285 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
286 -|=(% style="width: 120px;" %)(((
288 +(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
289 +|=(% style="width: 121px;" %)(((
287 287  (((
288 288  **AT Commands**
289 289  )))
290 -)))|=(% style="width: 190px;" %)(((
293 +)))|=(% style="width: 110px;" %)(((
291 291  (((
292 292  **Description**
293 293  )))
294 -)))|=(% style="width: 190px;" %)(((
297 +)))|=(% style="width: 200px;" %)(((
295 295  (((
296 296  **Example**
297 297  )))
298 298  )))
299 -|(% style="width:120px" %)(((
302 +|(% style="width:200px" %)(((
300 300  (((
301 301  AT+BAUDR
302 302  )))
303 -)))|(% style="width:190px" %)(((
306 +)))|(% style="width:303px" %)(((
304 304  (((
305 305  Set the baud rate (for RS485 connection). Default Value is: 9600.
306 306  )))
307 -)))|(% style="width:190px" %)(((
310 +)))|(% style="width:340px" %)(((
308 308  (((
309 309  (((
310 310  AT+BAUDR=9600
... ... @@ -317,11 +317,11 @@
317 317  )))
318 318  )))
319 319  )))
320 -|(% style="width:120px" %)(((
323 +|(% style="width:121px" %)(((
321 321  (((
322 322  AT+PARITY
323 323  )))
324 -)))|(% style="width:190px" %)(((
327 +)))|(% style="width:303px" %)(((
325 325  (((
326 326  (((
327 327  Set UART parity (for RS485 connection)
... ... @@ -333,7 +333,7 @@
333 333  Default Value is: no parity.
334 334  )))
335 335  )))
336 -)))|(% style="width:190px" %)(((
339 +)))|(% style="width:340px" %)(((
337 337  (((
338 338  (((
339 339  AT+PARITY=0
... ... @@ -346,11 +346,11 @@
346 346  )))
347 347  )))
348 348  )))
349 -|(% style="width:120px" %)(((
352 +|(% style="width:121px" %)(((
350 350  (((
351 351  AT+STOPBIT
352 352  )))
353 -)))|(% style="width:190px" %)(((
356 +)))|(% style="width:303px" %)(((
354 354  (((
355 355  (((
356 356  Set serial stopbit (for RS485 connection)
... ... @@ -362,7 +362,7 @@
362 362  Default Value is: 1bit.
363 363  )))
364 364  )))
365 -)))|(% style="width:190px" %)(((
368 +)))|(% style="width:340px" %)(((
366 366  (((
367 367  (((
368 368  AT+STOPBIT=0 for 1bit
... ... @@ -394,20 +394,19 @@
394 394  When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling.
395 395  )))
396 396  
397 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
398 -|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
399 -|AT+CFGDEV|(% style="width:120px" %)(((
400 +(% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
401 +|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
402 +|AT+CFGDEV|(% style="width:418px" %)(((
400 400  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
401 401  
402 402  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
403 403  
404 404  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
405 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
408 +)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
406 406  
407 407  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
408 408  
409 409  
410 -
411 411  === 3.3.3 Configure read commands for each sampling ===
412 412  
413 413  (((
... ... @@ -480,7 +480,7 @@
480 480  
481 481  **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
482 482  
483 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
485 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:501px" %)
484 484  |(% style="width:498px" %)(((
485 485  **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
486 486  
... ... @@ -495,7 +495,7 @@
495 495  
496 496  **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
497 497  
498 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
500 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:580px" %)
499 499  |(% style="width:577px" %)(((
500 500  **AT+SEARCHx=aa,xx xx xx xx xx**
501 501  
... ... @@ -523,7 +523,7 @@
523 523  
524 524  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
525 525  
526 -(% style="background-color:#4f81bd; color:white; width:510px" %)
528 +(% style="background-color:#4f81bd; color:white; width:729px" %)
527 527  |(% style="width:726px" %)(((
528 528  **AT+DATACUTx=a,b,c**
529 529  
... ... @@ -591,14 +591,10 @@
591 591  
592 592  (((
593 593  Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
594 -
595 -
596 596  )))
597 597  
598 598  (((
599 599  (% style="color:#037691" %)**Examples: AT+DATAUP=0**
600 -
601 -
602 602  )))
603 603  
604 604  (((
... ... @@ -816,6 +816,7 @@
816 816  
817 817  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
818 818  
817 +
819 819  === 3.5.1 Common Commands: ===
820 820  
821 821  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1175,6 +1175,7 @@
1175 1175  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1176 1176  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1177 1177  
1177 +
1178 1178  == 3.7 +3V3 Output ==
1179 1179  
1180 1180  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1215,6 +1215,7 @@
1215 1215  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1216 1216  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1217 1217  
1218 +
1218 1218  == 3.10 Switch Jumper ==
1219 1219  
1220 1220  (% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
... ... @@ -1402,6 +1402,8 @@
1402 1402  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1403 1403  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1404 1404  
1406 +
1407 +
1405 1405  = 9. Packing Info =
1406 1406  
1407 1407  (((