Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -382,6 +382,8 @@ 382 382 ))) 383 383 ))) 384 384 385 + 386 + 385 385 === 3.3.2 Configure sensors === 386 386 387 387 ((( ... ... @@ -405,6 +405,7 @@ 405 405 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 406 406 407 407 410 + 408 408 === 3.3.3 Configure read commands for each sampling === 409 409 410 410 ((( ... ... @@ -471,117 +471,213 @@ 471 471 After we got the valid value from each RS485 commands, we need to combine them together with the command **AT+DATAUP**. 472 472 ))) 473 473 477 +((( 474 474 **Examples:** 479 +))) 475 475 481 +((( 476 476 Below are examples for the how above AT Commands works. 483 +))) 477 477 485 +((( 478 478 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is: 487 +))) 479 479 480 480 (% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %) 481 481 |(% style="width:498px" %)((( 491 +((( 482 482 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 493 +))) 483 483 495 +((( 484 484 **xx xx xx xx xx xx xx xx xx xx xx xx: The RS485 command to be sent** 497 +))) 485 485 499 +((( 486 486 **m: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command** 487 487 ))) 502 +))) 488 488 504 +((( 489 489 For example, if we have a RS485 sensor. The command to get sensor value is: 01 03 0B B8 00 02 46 0A. Where 01 03 0B B8 00 02 is the Modbus command to read the register 0B B8 where stored the sensor value. The 46 0A is the CRC-16/MODBUS which calculate manually. 506 +))) 490 490 508 +((( 491 491 In the RS485-BL, we should use this command AT+COMMAND1=01 03 0B B8 00 02,1 for the same. 510 +))) 492 492 512 +((( 513 + 514 +))) 515 + 516 +((( 493 493 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 518 +))) 494 494 495 495 (% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %) 496 496 |(% style="width:577px" %)((( 522 +((( 497 497 **AT+SEARCHx=aa,xx xx xx xx xx** 524 +))) 498 498 499 -* **aa: 1: prefix match mode; 2: prefix and suffix match mode**500 -* *xxxxxxxx xx:matchstring. Max 5 bytesforprefix and5 bytesfor suffix**526 +* ((( 527 +**aa: 1: prefix match mode; 2: prefix and suffix match mode** 501 501 ))) 529 +* ((( 530 +**xx xx xx xx xx: match string. Max 5 bytes for prefix and 5 bytes for suffix** 531 +))) 532 +))) 502 502 534 +((( 503 503 **Examples:** 536 +))) 504 504 538 +((( 505 505 1)For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 540 +))) 506 506 542 +((( 507 507 If we set AT+SEARCH1=1,1E 56 34. (max 5 bytes for prefix) 544 +))) 508 508 546 +((( 509 509 The valid data will be all bytes after 1E 56 34 , so it is (% style="background-color:yellow" %)**2e 30 58 5f 36 41 30 31 00 49** 548 +))) 510 510 550 +((( 511 511 [[image:1653271044481-711.png]] 552 +))) 512 512 554 +((( 513 513 2)For a return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 556 +))) 514 514 558 +((( 515 515 If we set AT+SEARCH1=2, 1E 56 34+31 00 49 560 +))) 516 516 562 +((( 517 517 Device will search the bytes between 1E 56 34 and 31 00 49. So it is(% style="background-color:yellow" %) **2e 30 58 5f 36 41 30** 564 +))) 518 518 566 +((( 519 519 [[image:1653271276735-972.png]] 568 +))) 520 520 570 +((( 521 521 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 572 +))) 522 522 523 523 (% style="background-color:#4f81bd; color:white; width:510px" %) 524 524 |(% style="width:726px" %)((( 576 +((( 525 525 **AT+DATACUTx=a,b,c** 578 +))) 526 526 527 -* **a: length for the return of AT+COMMAND** 528 -* **b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.** 529 -* **c: define the position for valid value. ** 580 +* ((( 581 +**a: length for the return of AT+COMMAND** 530 530 ))) 583 +* ((( 584 +**b:1: grab valid value by byte, max 6 bytes. 2: grab valid value by bytes section, max 3 sections.** 585 +))) 586 +* ((( 587 +**c: define the position for valid value. ** 588 +))) 589 +))) 531 531 591 +((( 532 532 **Examples:** 593 +))) 533 533 534 -* Grab bytes: 595 +* ((( 596 +Grab bytes: 597 +))) 535 535 599 +((( 536 536 [[image:1653271581490-837.png||height="313" width="722"]] 601 +))) 537 537 603 +((( 604 + 605 +))) 538 538 539 -* Grab a section. 607 +* ((( 608 +Grab a section. 609 +))) 540 540 611 +((( 541 541 [[image:1653271648378-342.png||height="326" width="720"]] 613 +))) 542 542 615 +((( 616 + 617 +))) 543 543 544 -* Grab different sections. 619 +* ((( 620 +Grab different sections. 621 +))) 545 545 623 +((( 546 546 [[image:1653271657255-576.png||height="305" width="730"]] 625 +))) 547 547 548 548 ((( 628 +((( 549 549 (% style="color:red" %)**Note:** 550 550 ))) 631 +))) 551 551 552 552 ((( 634 +((( 553 553 AT+SEARCHx and AT+DATACUTx can be used together, if both commands are set, RS485-BL will first process AT+SEARCHx on the return string and get a temporary string, and then process AT+DATACUTx on this temporary string to get the final payload. In this case, AT+DATACUTx need to set to format AT+DATACUTx=0,xx,xx where the return bytes set to 0. 554 554 ))) 637 +))) 555 555 556 556 ((( 640 +((( 557 557 **Example:** 558 558 ))) 643 +))) 559 559 560 560 ((( 646 +((( 561 561 (% style="color:red" %)AT+COMMAND1=11 01 1E D0,0 562 562 ))) 649 +))) 563 563 564 564 ((( 652 +((( 565 565 (% style="color:red" %)AT+SEARCH1=1,1E 56 34 566 566 ))) 655 +))) 567 567 568 568 ((( 658 +((( 569 569 (% style="color:red" %)AT+DATACUT1=0,2,1~~5 570 570 ))) 661 +))) 571 571 572 572 ((( 664 +((( 573 573 (% style="color:red" %)Return string from AT+COMMAND1: 16 0c 1e 56 34 2e 30 58 5f 36 41 30 31 00 49 574 574 ))) 667 +))) 575 575 576 576 ((( 670 +((( 577 577 (% style="color:red" %)String after SEARCH command: 2e 30 58 5f 36 41 30 31 00 49 578 578 ))) 673 +))) 579 579 580 580 ((( 676 +((( 581 581 (% style="color:red" %)Valid payload after DataCUT command: 2e 30 58 5f 36 582 582 ))) 679 +))) 583 583 681 +((( 584 584 [[image:1653271763403-806.png]] 683 +))) 585 585 586 586 587 587 === 3.3.4 Compose the uplink payload === ... ... @@ -728,26 +728,8 @@ 728 728 729 729 == 3.4 Uplink Payload == 730 730 731 -(% border="1" style="background-color:#4f81bd; color:white; width:850px" %) 732 -|**Size(bytes)**|(% style="width:130px" %)**2**|(% style="width:93px" %)**1**|(% style="width:509px" %)**Length depends on the return from the commands** 733 -|Value|(% style="width:130px" %)((( 734 -((( 735 -Battery(mV) 736 -))) 830 +[[image:image-20220606105412-1.png]] 737 737 738 -((( 739 -& 740 -))) 741 - 742 -((( 743 -Interrupt _Flag 744 -))) 745 -)))|(% style="width:93px" %)((( 746 -PAYLOAD_VER 747 - 748 - 749 -)))|(% style="width:509px" %)If the valid payload is too long and exceed the maximum support payload length in server, server will show payload not provided in the LoRaWAN server. 750 - 751 751 Below is the decoder for the first 3 bytes. The rest bytes are dynamic depends on different RS485 sensors. 752 752 753 753 ((( ... ... @@ -791,7 +791,7 @@ 791 791 ))) 792 792 793 793 ((( 794 - **}**875 +{{{}}}} 795 795 796 796 797 797 ))) ... ... @@ -805,14 +805,24 @@ 805 805 806 806 == 3.5 Configure RS485-BL via AT or Downlink == 807 807 889 +((( 808 808 User can configure RS485-BL via AT Commands or LoRaWAN Downlink Commands 891 +))) 809 809 893 +((( 810 810 There are two kinds of Commands: 895 +))) 811 811 812 -* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 897 +* ((( 898 +(% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 899 +))) 813 813 814 -* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 901 +* ((( 902 +(% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL. User can see these commands below: 903 +))) 815 815 905 + 906 + 816 816 === 3.5.1 Common Commands: === 817 817 818 818 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -821,6 +821,7 @@ 821 821 === 3.5.2 Sensor related commands: === 822 822 823 823 915 + 824 824 ==== **Choose Device Type (RS485 or TTL)** ==== 825 825 826 826 RS485-BL can connect to either RS485 sensors or TTL sensor. User need to specify what type of sensor need to connect. ... ... @@ -844,57 +844,109 @@ 844 844 845 845 846 846 939 + 847 847 ==== **RS485 Debug Command (AT+CFGDEV)** ==== 848 848 942 +((( 849 849 This command is used to configure the RS485 or TTL sensors; they won’t be used during sampling. 944 +))) 850 850 851 -* **AT Command** 946 +* ((( 947 +**AT Command** 948 +))) 852 852 853 853 (% class="box infomessage" %) 854 854 ((( 952 +((( 855 855 **AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m** 856 856 ))) 955 +))) 857 857 957 +((( 858 858 m: 0: no CRC; 1: add CRC-16/MODBUS in the end of this command. 959 +))) 859 859 961 +((( 962 + 963 +))) 860 860 861 -* **Downlink Payload** 965 +* ((( 966 +**Downlink Payload** 967 +))) 862 862 969 +((( 863 863 Format: A8 MM NN XX XX XX XX YY 971 +))) 864 864 973 +((( 865 865 Where: 975 +))) 866 866 867 -* MM: 1: add CRC-16/MODBUS ; 0: no CRC 868 -* NN: The length of RS485 command 869 -* XX XX XX XX: RS485 command total NN bytes 870 -* YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 977 +* ((( 978 +MM: 1: add CRC-16/MODBUS ; 0: no CRC 979 +))) 980 +* ((( 981 +NN: The length of RS485 command 982 +))) 983 +* ((( 984 +XX XX XX XX: RS485 command total NN bytes 985 +))) 986 +* ((( 987 +YY: How many bytes will be uplink from the return of this RS485 command, if YY=0, RS485-BL will execute the downlink command without uplink; if YY>0, RS485-BL will uplink total YY bytes from the output of this RS485 command 988 +))) 871 871 990 +((( 872 872 **Example 1:** 992 +))) 873 873 994 +((( 874 874 To connect a Modbus Alarm with below commands. 996 +))) 875 875 876 -* The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 998 +* ((( 999 +The command to active alarm is: 0A 05 00 04 00 01 **4C B0**. Where 0A 05 00 04 00 01 is the Modbus command to read the register 00 40 where stored the DI status. The 4C B0 is the CRC-16/MODBUS which calculate manually. 1000 +))) 877 877 878 -* The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1002 +* ((( 1003 +The command to deactivate alarm is: 0A 05 00 04 00 00 **8D 70**. Where 0A 05 00 04 00 00 is the Modbus command to read the register 00 40 where stored the DI status. The 8D 70 is the CRC-16/MODBUS which calculate manually. 1004 +))) 879 879 1006 +((( 880 880 So if user want to use downlink command to control to RS485 Alarm, he can use: 1008 +))) 881 881 1010 +((( 882 882 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 01 00**(%%): to activate the RS485 Alarm 1012 +))) 883 883 1014 +((( 884 884 (% style="color:#037691" %)**A8 01 06 0A 05 00 04 00 00 00**(%%): to deactivate the RS485 Alarm 1016 +))) 885 885 1018 +((( 886 886 A8 is type code and 01 means add CRC-16/MODBUS at the end, the 3^^rd^^ byte is 06, means the next 6 bytes are the command to be sent to the RS485 network, the final byte 00 means this command don’t need to acquire output. 1020 +))) 887 887 1022 +((( 1023 + 1024 +))) 888 888 1026 +((( 889 889 **Example 2:** 1028 +))) 890 890 1030 +((( 891 891 Check TTL Sensor return: 1032 +))) 892 892 1034 +((( 893 893 [[image:1654132684752-193.png]] 1036 +))) 894 894 895 895 896 896 897 897 1041 + 898 898 ==== **Set Payload version** ==== 899 899 900 900 This is the first byte of the uplink payload. RS485-BL can connect to different sensors. User can set the PAYVER field to tell server how to decode the current payload. ... ... @@ -915,67 +915,128 @@ 915 915 916 916 917 917 1062 + 918 918 ==== **Set RS485 Sampling Commands** ==== 919 919 1065 +((( 920 920 AT+COMMANDx, AT+DATACUTx and AT+SEARCHx 1067 +))) 921 921 1069 +((( 922 922 These three commands are used to configure how the RS485-BL polling data from Modbus device. Detail of usage please see : [[polling RS485 device>>||anchor="H3.3.3Configurereadcommandsforeachsampling"]]. 1071 +))) 923 923 1073 +((( 1074 + 1075 +))) 924 924 925 -* **AT Command:** 1077 +* ((( 1078 +**AT Command:** 1079 +))) 926 926 927 927 (% class="box infomessage" %) 928 928 ((( 1083 +((( 929 929 **AT+COMMANDx: Configure RS485 read command to sensor.** 930 930 ))) 1086 +))) 931 931 932 932 (% class="box infomessage" %) 933 933 ((( 1090 +((( 934 934 **AT+DATACUTx: Configure how to handle return from RS485 devices.** 935 935 ))) 1093 +))) 936 936 937 937 (% class="box infomessage" %) 938 938 ((( 1097 +((( 939 939 **AT+SEARCHx: Configure search command** 940 940 ))) 1100 +))) 941 941 1102 +((( 1103 + 1104 +))) 942 942 943 -* **Downlink Payload:** 1106 +* ((( 1107 +**Downlink Payload:** 1108 +))) 944 944 1110 +((( 945 945 **0xAF** downlink command can be used to set AT+COMMANDx or AT+DATACUTx. 1112 +))) 946 946 1114 +((( 947 947 (% style="color:red" %)**Note**(%%): if user use AT+COMMANDx to add a new command, he also need to send AT+DATACUTx downlink. 1116 +))) 948 948 1118 +((( 949 949 Format: AF MM NN LL XX XX XX XX YY 1120 +))) 950 950 1122 +((( 951 951 Where: 1124 +))) 952 952 953 -* MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 954 -* NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 955 -* LL: The length of AT+COMMAND or AT+DATACUT command 956 -* XX XX XX XX: AT+COMMAND or AT+DATACUT command 957 -* YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 1126 +* ((( 1127 +MM: the ATCOMMAND or AT+DATACUT to be set. Value from 01 ~~ 0F, 1128 +))) 1129 +* ((( 1130 +NN: 0: no CRC; 1: add CRC-16/MODBUS ; 2: set the AT+DATACUT value. 1131 +))) 1132 +* ((( 1133 +LL: The length of AT+COMMAND or AT+DATACUT command 1134 +))) 1135 +* ((( 1136 +XX XX XX XX: AT+COMMAND or AT+DATACUT command 1137 +))) 1138 +* ((( 1139 +YY: If YY=0, RS485-BL will execute the downlink command without uplink; if YY=1, RS485-BL will execute an uplink after got this command. 1140 +))) 958 958 1142 +((( 959 959 **Example:** 1144 +))) 960 960 1146 +((( 961 961 (% style="color:#037691" %)**AF 03 01 06 0A 05 00 04 00 01 00**(%%): Same as AT+COMMAND3=0A 05 00 04 00 01,1 1148 +))) 962 962 1150 +((( 963 963 (% style="color:#037691" %)**AF 03 02 06**(% style="color:orange" %)** 10 **(% style="color:red" %)**01 **(% style="color:green" %)**05 06 09 0A**(% style="color:#037691" %)** 00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**16**(%%),(% style="color:red" %)**1**(%%),(% style="color:green" %)**5+6+9+10** 1152 +))) 964 964 1154 +((( 965 965 (% style="color:#037691" %)**AF 03 02 06 **(% style="color:orange" %)**0B**(% style="color:red" %)** 02 **(% style="color:green" %)**05 07 08 0A **(% style="color:#037691" %)**00**(%%): Same as AT+DATACUT3=(% style="color:orange" %)**11**(%%),(% style="color:red" %)**2**(%%),(% style="color:green" %)**5~~7+8~~10** 1156 +))) 966 966 1158 +((( 1159 + 1160 +))) 967 967 1162 +((( 968 968 **0xAB** downlink command can be used for set AT+SEARCHx 1164 +))) 969 969 1166 +((( 970 970 **Example:** **AB aa 01 03 xx xx xx** (03 here means there are total 3 bytes after 03) So 1168 +))) 971 971 972 -* AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 973 -* AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 1170 +* ((( 1171 +AB aa 01 03 xx xx xx same as AT+SEARCHaa=1,xx xx xx 1172 +))) 1173 +* ((( 1174 +AB aa 02 03 xx xx xx 02 yy yy(03 means there are 3 bytes after 03, they are xx xx xx;02 means there are 2 bytes after 02, they are yy yy) so the commands 1175 +))) 974 974 1177 +((( 975 975 **AB aa 02 03 xx xx xx 02 yy yy** same as **AT+SEARCHaa=2,xx xx xx+yy yy** 1179 +))) 976 976 977 977 978 978 1183 + 979 979 ==== **Fast command to handle MODBUS device** ==== 980 980 981 981 AT+MBFUN is valid since v1.3 firmware version. The command is for fast configure to read Modbus devices. It is only valid for the devices which follow the [[MODBUS-RTU protocol>>url:https://www.modbustools.com/modbus.html]]. ... ... @@ -1009,6 +1009,7 @@ 1009 1009 1010 1010 1011 1011 1217 + 1012 1012 ==== **RS485 command timeout** ==== 1013 1013 1014 1014 Some Modbus device has slow action to send replies. This command is used to configure the RS485-BL to use longer time to wait for their action. ... ... @@ -1040,6 +1040,7 @@ 1040 1040 1041 1041 1042 1042 1249 + 1043 1043 ==== **Uplink payload mode** ==== 1044 1044 1045 1045 Define to use one uplink or multiple uplinks for the sampling. ... ... @@ -1086,7 +1086,9 @@ 1086 1086 1087 1087 * **AT Command:** 1088 1088 1296 +((( 1089 1089 (% style="color:#037691" %)**AT+CMDEAR=mm,nn** (%%) mm: start position of erase ,nn: stop position of erase Etc. AT+CMDEAR=1,10 means erase AT+COMMAND1/AT+DATACUT1 to AT+COMMAND10/AT+DATACUT10 1298 +))) 1090 1090 1091 1091 Example screen shot after clear all RS485 commands. 1092 1092 ... ... @@ -1102,6 +1102,7 @@ 1102 1102 1103 1103 1104 1104 1314 + 1105 1105 ==== **Set Serial Communication Parameters** ==== 1106 1106 1107 1107 Set the Rs485 serial communication parameters: ... ... @@ -1145,6 +1145,7 @@ 1145 1145 1146 1146 1147 1147 1358 + 1148 1148 ==== **Control output power duration** ==== 1149 1149 1150 1150 User can set the output power duration before each sampling. ... ... @@ -1168,44 +1168,83 @@ 1168 1168 1169 1169 == 3.6 Buttons == 1170 1170 1171 -(% border="1" style="background-color:#ffffcc; color:green; width:233px" %) 1382 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:233px" %) 1172 1172 |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature** 1173 1173 |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL 1174 1174 1386 + 1387 + 1175 1175 == 3.7 +3V3 Output == 1176 1176 1390 +((( 1177 1177 RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor. 1392 +))) 1178 1178 1394 +((( 1179 1179 The +3V3 output will be valid for every sampling. RS485-BL will enable +3V3 output before all sampling and disable the +3V3 after all sampling. 1396 +))) 1180 1180 1398 +((( 1181 1181 The +3V3 output time can be controlled by AT Command. 1400 +))) 1182 1182 1402 +((( 1403 + 1404 +))) 1183 1183 1406 +((( 1184 1184 (% style="color:#037691" %)**AT+3V3T=1000** 1408 +))) 1185 1185 1410 +((( 1411 + 1412 +))) 1186 1186 1414 +((( 1187 1187 Means set +3v3 valid time to have 1000ms. So, the real +3v3 output will actually have 1000ms + sampling time for other sensors. 1416 +))) 1188 1188 1418 +((( 1189 1189 By default, the AT+3V3T=0. This is a special case, means the +3V3 output is always on at any time 1420 +))) 1190 1190 1191 1191 1192 1192 == 3.8 +5V Output == 1193 1193 1425 +((( 1194 1194 RS485-BL has a Controllable +5V output, user can use this output to power external sensor. 1427 +))) 1195 1195 1429 +((( 1196 1196 The +5V output will be valid for every sampling. RS485-BL will enable +5V output before all sampling and disable the +5v after all sampling. 1431 +))) 1197 1197 1433 +((( 1198 1198 The 5V output time can be controlled by AT Command. 1435 +))) 1199 1199 1437 +((( 1438 + 1439 +))) 1200 1200 1441 +((( 1201 1201 (% style="color:#037691" %)**AT+5VT=1000** 1443 +))) 1202 1202 1445 +((( 1446 + 1447 +))) 1203 1203 1449 +((( 1204 1204 Means set 5V valid time to have 1000ms. So, the real 5V output will actually have 1000ms + sampling time for other sensors. 1451 +))) 1205 1205 1453 +((( 1206 1206 By default, the AT+5VT=0. If the external sensor which require 5v and require more time to get stable state, user can use this command to increase the power ON duration for this sensor. 1455 +))) 1207 1207 1208 1208 1458 + 1209 1209 == 3.9 LEDs == 1210 1210 1211 1211 (% border="1" style="background-color:#ffffcc; color:green; width:332px" %) ... ... @@ -1212,6 +1212,8 @@ 1212 1212 |=**LEDs**|=(% style="width: 274px;" %)**Feature** 1213 1213 |**LED1**|(% style="width:274px" %)Blink when device transmit a packet. 1214 1214 1465 + 1466 + 1215 1215 == 3.10 Switch Jumper == 1216 1216 1217 1217 (% border="1" style="background-color:#ffffcc; color:green; width:515px" %) ... ... @@ -1227,9 +1227,13 @@ 1227 1227 3.3v position: set to compatible with 3.3v I/O., 1228 1228 ))) 1229 1229 1482 +((( 1230 1230 **+3.3V**: is always ON 1484 +))) 1231 1231 1486 +((( 1232 1232 **+5V**: Only open before every sampling. The time is by default, it is AT+5VT=0. Max open time. 5000 ms. 1488 +))) 1233 1233 1234 1234 1235 1235 = 4. Case Study = ... ... @@ -1241,17 +1241,23 @@ 1241 1241 1242 1242 == 5.1 Access AT Command == 1243 1243 1500 +((( 1244 1244 RS485-BL supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to RS485-BL to use AT command, as below. 1502 +))) 1245 1245 1246 1246 [[image:1654135840598-282.png]] 1247 1247 1248 1248 1507 +((( 1249 1249 In PC, User needs to set (% style="color:blue" %)**serial tool**(%%)(such as [[putty>>url:https://www.chiark.greenend.org.uk/~~sgtatham/putty/latest.html]], SecureCRT) baud rate to (% style="color:green" %)**9600**(%%) to access to access serial console of RS485-BL. The default password is 123456. Below is the output for reference: 1509 +))) 1250 1250 1251 1251 [[image:1654136105500-922.png]] 1252 1252 1253 1253 1514 +((( 1254 1254 More detail AT Command manual can be found at [[AT Command Manual>>||anchor="H3.5ConfigureRS485-BLviaATorDownlink"]] 1516 +))) 1255 1255 1256 1256 1257 1257 == 5.2 Common AT Command Sequence == ... ... @@ -1276,7 +1276,9 @@ 1276 1276 ))) 1277 1277 1278 1278 1541 +((( 1279 1279 If device already joined network: 1543 +))) 1280 1280 1281 1281 (% class="box infomessage" %) 1282 1282 ((( ... ... @@ -1315,10 +1315,12 @@ 1315 1315 1316 1316 (% style="color:red" %)**Note:** 1317 1317 1582 +((( 1318 1318 (% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1319 1319 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1320 1320 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1321 1321 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1587 +))) 1322 1322 1323 1323 [[image:1654136435598-589.png]] 1324 1324 ... ... @@ -1327,13 +1327,23 @@ 1327 1327 1328 1328 == 6.1 How to upgrade the image? == 1329 1329 1596 +((( 1330 1330 The RS485-BL LoRaWAN Controller is shipped with a 3.5mm cable, the cable is used to upload image to RS485-BL to: 1598 +))) 1331 1331 1332 -* Support new features 1333 -* For bug fix 1334 -* Change LoRaWAN bands. 1600 +* ((( 1601 +Support new features 1602 +))) 1603 +* ((( 1604 +For bug fix 1605 +))) 1606 +* ((( 1607 +Change LoRaWAN bands. 1608 +))) 1335 1335 1610 +((( 1336 1336 Below shows the hardware connection for how to upload an image to RS485-BL: 1612 +))) 1337 1337 1338 1338 [[image:1654136646995-976.png]] 1339 1339 ... ... @@ -1399,6 +1399,8 @@ 1399 1399 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1400 1400 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1401 1401 1678 + 1679 + 1402 1402 = 9. Packing Info = 1403 1403 1404 1404 (((
- image-20220606105412-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.9 KB - Content