Last modified by Xiaoling on 2025/04/23 15:57

From version 40.49
edited by Xiaoling
on 2022/06/06 10:39
Change comment: There is no comment for this version
To version 40.46
edited by Xiaoling
on 2022/06/06 10:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -382,7 +382,6 @@
382 382  )))
383 383  )))
384 384  
385 -
386 386  === 3.3.2 Configure sensors ===
387 387  
388 388  (((
... ... @@ -393,15 +393,15 @@
393 393  When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling.
394 394  )))
395 395  
396 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
397 -|=**AT Commands**|=(% style="width: 110px;" %)**Description**|=(% style="width: 190px;" %)**Example**
398 -|AT+CFGDEV|(% style="width:190px" %)(((
395 +(% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
396 +|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
397 +|AT+CFGDEV|(% style="width:418px" %)(((
399 399  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
400 400  
401 401  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
402 402  
403 403  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
404 -)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
403 +)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
405 405  
406 406  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
407 407  
... ... @@ -478,7 +478,7 @@
478 478  
479 479  **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
480 480  
481 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
480 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:501px" %)
482 482  |(% style="width:498px" %)(((
483 483  **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
484 484  
... ... @@ -493,7 +493,7 @@
493 493  
494 494  **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
495 495  
496 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
495 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:580px" %)
497 497  |(% style="width:577px" %)(((
498 498  **AT+SEARCHx=aa,xx xx xx xx xx**
499 499  
... ... @@ -521,7 +521,7 @@
521 521  
522 522  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
523 523  
524 -(% style="background-color:#4f81bd; color:white; width:510px" %)
523 +(% style="background-color:#4f81bd; color:white; width:729px" %)
525 525  |(% style="width:726px" %)(((
526 526  **AT+DATACUTx=a,b,c**
527 527