Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -282,29 +282,29 @@ 282 282 RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match. 283 283 ))) 284 284 285 -(% border="1" cellspacing=" 10" style="background-color:#ffffcc; color:green; width:510px" %)286 -|=(% style="width: 12 0px;" %)(((285 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %) 286 +|=(% style="width: 125px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) 290 -)))|=(% style="width: 1 90px;" %)(((290 +)))|=(% style="width: 110px;" %)((( 291 291 ((( 292 292 **Description** 293 293 ))) 294 -)))|=(% style="width: 190px;" %)(((294 +)))|=(% style="width: 255px;" %)((( 295 295 ((( 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width:12 0px" %)(((299 +|(% style="width:125px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) 303 -)))|(% style="width:1 90px" %)(((303 +)))|(% style="width:110px" %)((( 304 304 ((( 305 305 Set the baud rate (for RS485 connection). Default Value is: 9600. 306 306 ))) 307 -)))|(% style="width: 190px" %)(((307 +)))|(% style="width:255px" %)((( 308 308 ((( 309 309 ((( 310 310 AT+BAUDR=9600 ... ... @@ -317,11 +317,11 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width:12 0px" %)(((320 +|(% style="width:125px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) 324 -)))|(% style="width:1 90px" %)(((324 +)))|(% style="width:110px" %)((( 325 325 ((( 326 326 ((( 327 327 Set UART parity (for RS485 connection) ... ... @@ -333,7 +333,7 @@ 333 333 Default Value is: no parity. 334 334 ))) 335 335 ))) 336 -)))|(% style="width: 190px" %)(((336 +)))|(% style="width:255px" %)((( 337 337 ((( 338 338 ((( 339 339 AT+PARITY=0 ... ... @@ -346,11 +346,11 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width:12 0px" %)(((349 +|(% style="width:125px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) 353 -)))|(% style="width:1 90px" %)(((353 +)))|(% style="width:110px" %)((( 354 354 ((( 355 355 ((( 356 356 Set serial stopbit (for RS485 connection) ... ... @@ -362,7 +362,7 @@ 362 362 Default Value is: 1bit. 363 363 ))) 364 364 ))) 365 -)))|(% style="width: 190px" %)(((365 +)))|(% style="width:255px" %)((( 366 366 ((( 367 367 ((( 368 368 AT+STOPBIT=0 for 1bit ... ... @@ -382,7 +382,6 @@ 382 382 ))) 383 383 ))) 384 384 385 - 386 386 === 3.3.2 Configure sensors === 387 387 388 388 ((( ... ... @@ -393,15 +393,15 @@ 393 393 When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling. 394 394 ))) 395 395 396 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)397 -| =**AT Commands**|=(% style="width:10px;" %)**Description**|=(% style="width:190px;" %)**Example**398 -|AT+CFGDEV|(% style="width:1 90px" %)(((395 +(% border="1" style="background-color:#ffffcc; color:green; width:806px" %) 396 +|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example** 397 +|AT+CFGDEV|(% style="width:418px" %)((( 399 399 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 400 400 401 401 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 402 402 403 403 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 404 -)))|(% style="width: 190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m403 +)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 405 405 406 406 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 407 407 ... ... @@ -478,7 +478,7 @@ 478 478 479 479 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is: 480 480 481 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:50 0px" %)480 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:501px" %) 482 482 |(% style="width:498px" %)((( 483 483 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 484 484 ... ... @@ -493,7 +493,7 @@ 493 493 494 494 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 495 495 496 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:50 0px" %)495 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:580px" %) 497 497 |(% style="width:577px" %)((( 498 498 **AT+SEARCHx=aa,xx xx xx xx xx** 499 499 ... ... @@ -521,7 +521,7 @@ 521 521 522 522 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 523 523 524 -(% style="background-color:#4f81bd; color:white; width: 510px" %)523 +(% style="background-color:#4f81bd; color:white; width:729px" %) 525 525 |(% style="width:726px" %)((( 526 526 **AT+DATACUTx=a,b,c** 527 527