Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -382,7 +382,6 @@ 382 382 ))) 383 383 ))) 384 384 385 - 386 386 === 3.3.2 Configure sensors === 387 387 388 388 ((( ... ... @@ -394,8 +394,8 @@ 394 394 ))) 395 395 396 396 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 397 -|=**AT Commands**|=(% style="width: 1 10px;" %)**Description**|=(% style="width: 190px;" %)**Example**398 -|AT+CFGDEV|(% style="width:1 90px" %)(((396 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example** 397 +|AT+CFGDEV|(% style="width:120px" %)((( 399 399 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 400 400 401 401 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, ... ... @@ -478,7 +478,7 @@ 478 478 479 479 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is: 480 480 481 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:50 1px" %)480 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %) 482 482 |(% style="width:498px" %)((( 483 483 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 484 484 ... ... @@ -493,7 +493,7 @@ 493 493 494 494 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 495 495 496 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:5 80px" %)495 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %) 497 497 |(% style="width:577px" %)((( 498 498 **AT+SEARCHx=aa,xx xx xx xx xx** 499 499 ... ... @@ -521,7 +521,7 @@ 521 521 522 522 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 523 523 524 -(% style="background-color:#4f81bd; color:white; width: 729px" %)523 +(% style="background-color:#4f81bd; color:white; width:510px" %) 525 525 |(% style="width:726px" %)((( 526 526 **AT+DATACUTx=a,b,c** 527 527 ... ... @@ -589,10 +589,14 @@ 589 589 590 590 ((( 591 591 Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.** 591 + 592 + 592 592 ))) 593 593 594 594 ((( 595 595 (% style="color:#037691" %)**Examples: AT+DATAUP=0** 597 + 598 + 596 596 ))) 597 597 598 598 (((