Last modified by Xiaoling on 2025/04/23 15:57

From version 40.47
edited by Xiaoling
on 2022/06/06 10:32
Change comment: There is no comment for this version
To version 40.51
edited by Xiaoling
on 2022/06/06 10:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -382,8 +382,6 @@
382 382  )))
383 383  )))
384 384  
385 -
386 -
387 387  === 3.3.2 Configure sensors ===
388 388  
389 389  (((
... ... @@ -394,15 +394,15 @@
394 394  When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling.
395 395  )))
396 396  
397 -(% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
398 -|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
399 -|AT+CFGDEV|(% style="width:418px" %)(((
395 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
396 +|=(% style="width: 120px;" %)**AT Commands**|=(% style="width: 190px;" %)**Description**|=(% style="width: 190px;" %)**Example**
397 +|AT+CFGDEV|(% style="width:120px" %)(((
400 400  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
401 401  
402 402  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
403 403  
404 404  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
405 -)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
403 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
406 406  
407 407  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
408 408  
... ... @@ -479,7 +479,7 @@
479 479  
480 480  **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
481 481  
482 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:501px" %)
480 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
483 483  |(% style="width:498px" %)(((
484 484  **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
485 485  
... ... @@ -494,7 +494,7 @@
494 494  
495 495  **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
496 496  
497 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:580px" %)
495 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
498 498  |(% style="width:577px" %)(((
499 499  **AT+SEARCHx=aa,xx xx xx xx xx**
500 500  
... ... @@ -522,7 +522,7 @@
522 522  
523 523  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
524 524  
525 -(% style="background-color:#4f81bd; color:white; width:729px" %)
523 +(% style="background-color:#4f81bd; color:white; width:510px" %)
526 526  |(% style="width:726px" %)(((
527 527  **AT+DATACUTx=a,b,c**
528 528  
... ... @@ -590,10 +590,14 @@
590 590  
591 591  (((
592 592  Through AT+COMMANDx and AT+DATACUTx we got valid value from each RS485 commands, Assume these valid value are RETURN1, RETURN2, .., to RETURNx. The next step is how to compose the LoRa Uplink Payload by these RETURNs. The command is **AT+DATAUP.**
591 +
592 +
593 593  )))
594 594  
595 595  (((
596 596  (% style="color:#037691" %)**Examples: AT+DATAUP=0**
597 +
598 +
597 597  )))
598 598  