Last modified by Xiaoling on 2025/04/23 15:57

From version 40.47
edited by Xiaoling
on 2022/06/06 10:32
Change comment: There is no comment for this version
To version 40.49
edited by Xiaoling
on 2022/06/06 10:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -383,7 +383,6 @@
383 383  )))
384 384  
385 385  
386 -
387 387  === 3.3.2 Configure sensors ===
388 388  
389 389  (((
... ... @@ -394,15 +394,15 @@
394 394  When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling.
395 395  )))
396 396  
397 -(% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
398 -|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
399 -|AT+CFGDEV|(% style="width:418px" %)(((
396 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
397 +|=**AT Commands**|=(% style="width: 110px;" %)**Description**|=(% style="width: 190px;" %)**Example**
398 +|AT+CFGDEV|(% style="width:190px" %)(((
400 400  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
401 401  
402 402  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
403 403  
404 404  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
405 -)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
404 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
406 406  
407 407  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
408 408  
... ... @@ -479,7 +479,7 @@
479 479  
480 480  **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
481 481  
482 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:501px" %)
481 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
483 483  |(% style="width:498px" %)(((
484 484  **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
485 485  
... ... @@ -494,7 +494,7 @@
494 494  
495 495  **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
496 496  
497 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:580px" %)
496 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
498 498  |(% style="width:577px" %)(((
499 499  **AT+SEARCHx=aa,xx xx xx xx xx**
500 500  
... ... @@ -522,7 +522,7 @@
522 522  
523 523  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
524 524  
525 -(% style="background-color:#4f81bd; color:white; width:729px" %)
524 +(% style="background-color:#4f81bd; color:white; width:510px" %)
526 526  |(% style="width:726px" %)(((
527 527  **AT+DATACUTx=a,b,c**
528 528