Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -283,7 +283,7 @@ 283 283 ))) 284 284 285 285 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 286 -|=(% style="width: 12 5px;" %)(((286 +|=(% style="width: 120px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) ... ... @@ -296,7 +296,7 @@ 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width:12 5px" %)(((299 +|(% style="width:120px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) ... ... @@ -317,7 +317,7 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width:12 5px" %)(((320 +|(% style="width:120px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) ... ... @@ -346,7 +346,7 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width:12 5px" %)(((349 +|(% style="width:120px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) ... ... @@ -382,6 +382,7 @@ 382 382 ))) 383 383 ))) 384 384 385 + 385 385 === 3.3.2 Configure sensors === 386 386 387 387 ((( ... ... @@ -392,15 +392,15 @@ 392 392 When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling. 393 393 ))) 394 394 395 -(% border="1" style="background-color:#ffffcc; color:green; width: 806px" %)396 -|**AT Commands**|(% style="width: 418px" %)**Description**|(% style="width:256px" %)**Example**397 -|AT+CFGDEV|(% style="width: 418px" %)(((396 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 397 +|=**AT Commands**|=(% style="width: 110px;" %)**Description**|=(% style="width: 190px;" %)**Example** 398 +|AT+CFGDEV|(% style="width:190px" %)((( 398 398 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 399 399 400 400 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 401 401 402 402 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 403 -)))|(% style="width: 256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m404 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 404 404 405 405 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 406 406 ... ... @@ -477,7 +477,7 @@ 477 477 478 478 **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is: 479 479 480 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:50 1px" %)481 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %) 481 481 |(% style="width:498px" %)((( 482 482 **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m** 483 483 ... ... @@ -492,7 +492,7 @@ 492 492 493 493 **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx. 494 494 495 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:5 80px" %)496 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %) 496 496 |(% style="width:577px" %)((( 497 497 **AT+SEARCHx=aa,xx xx xx xx xx** 498 498 ... ... @@ -520,7 +520,7 @@ 520 520 521 521 **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes. 522 522 523 -(% style="background-color:#4f81bd; color:white; width: 729px" %)524 +(% style="background-color:#4f81bd; color:white; width:510px" %) 524 524 |(% style="width:726px" %)((( 525 525 **AT+DATACUTx=a,b,c** 526 526