Last modified by Xiaoling on 2025/04/23 15:57

From version 40.45
edited by Xiaoling
on 2022/06/06 10:28
Change comment: There is no comment for this version
To version 40.49
edited by Xiaoling
on 2022/06/06 10:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -283,7 +283,7 @@
283 283  )))
284 284  
285 285  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
286 -|=(% style="width: 125px;" %)(((
286 +|=(% style="width: 120px;" %)(((
287 287  (((
288 288  **AT Commands**
289 289  )))
... ... @@ -296,7 +296,7 @@
296 296  **Example**
297 297  )))
298 298  )))
299 -|(% style="width:125px" %)(((
299 +|(% style="width:120px" %)(((
300 300  (((
301 301  AT+BAUDR
302 302  )))
... ... @@ -317,7 +317,7 @@
317 317  )))
318 318  )))
319 319  )))
320 -|(% style="width:125px" %)(((
320 +|(% style="width:120px" %)(((
321 321  (((
322 322  AT+PARITY
323 323  )))
... ... @@ -346,7 +346,7 @@
346 346  )))
347 347  )))
348 348  )))
349 -|(% style="width:125px" %)(((
349 +|(% style="width:120px" %)(((
350 350  (((
351 351  AT+STOPBIT
352 352  )))
... ... @@ -382,6 +382,7 @@
382 382  )))
383 383  )))
384 384  
385 +
385 385  === 3.3.2 Configure sensors ===
386 386  
387 387  (((
... ... @@ -392,15 +392,15 @@
392 392  When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling.
393 393  )))
394 394  
395 -(% border="1" style="background-color:#ffffcc; color:green; width:806px" %)
396 -|**AT Commands**|(% style="width:418px" %)**Description**|(% style="width:256px" %)**Example**
397 -|AT+CFGDEV|(% style="width:418px" %)(((
396 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
397 +|=**AT Commands**|=(% style="width: 110px;" %)**Description**|=(% style="width: 190px;" %)**Example**
398 +|AT+CFGDEV|(% style="width:190px" %)(((
398 398  This command is used to configure the RS485/TTL devices; they won’t be used during sampling.
399 399  
400 400  AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,
401 401  
402 402  mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command
403 -)))|(% style="width:256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
404 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m
404 404  
405 405  Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]].
406 406  
... ... @@ -477,7 +477,7 @@
477 477  
478 478  **AT+COMMANDx : **This command will be sent to RS485/TTL devices during each sampling, Max command length is 14 bytes. The grammar is:
479 479  
480 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:501px" %)
481 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
481 481  |(% style="width:498px" %)(((
482 482  **AT+COMMANDx=xx xx xx xx xx xx xx xx xx xx xx xx,m**
483 483  
... ... @@ -492,7 +492,7 @@
492 492  
493 493  **AT+SEARCHx**: This command defines how to handle the return from AT+COMMANDx.
494 494  
495 -(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:580px" %)
496 +(% border="1" class="table-bordered" style="background-color:#4f81bd; color:white; width:500px" %)
496 496  |(% style="width:577px" %)(((
497 497  **AT+SEARCHx=aa,xx xx xx xx xx**
498 498  
... ... @@ -520,7 +520,7 @@
520 520  
521 521  **AT+DATACUTx : **This command defines how to handle the return from AT+COMMANDx, max return length is 45 bytes.
522 522  
523 -(% style="background-color:#4f81bd; color:white; width:729px" %)
524 +(% style="background-color:#4f81bd; color:white; width:510px" %)
524 524  |(% style="width:726px" %)(((
525 525  **AT+DATACUTx=a,b,c**
526 526