Last modified by Xiaoling on 2025/04/23 15:57

From version 40.43
edited by Xiaoling
on 2022/06/06 10:21
Change comment: There is no comment for this version
To version 40.40
edited by Xiaoling
on 2022/06/06 10:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -94,6 +94,7 @@
94 94  * 127 dB Dynamic Range RSSI.
95 95  * Automatic RF Sense and CAD with ultra-fast AFC. ​​​
96 96  
97 +
97 97  == 1.3 Features ==
98 98  
99 99  * LoRaWAN Class A & Class C protocol (default Class A)
... ... @@ -105,6 +105,7 @@
105 105  * Support Modbus protocol
106 106  * Support Interrupt uplink
107 107  
109 +
108 108  == 1.4 Applications ==
109 109  
110 110  * Smart Buildings & Home Automation
... ... @@ -114,6 +114,7 @@
114 114  * Smart Cities
115 115  * Smart Factory
116 116  
119 +
117 117  == 1.5 Firmware Change log ==
118 118  
119 119  [[RS485-BL Image files – Download link and Change log>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/RS485-BL/Firmware/||style="background-color: rgb(255, 255, 255);"]]
... ... @@ -282,8 +282,8 @@
282 282  RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match.
283 283  )))
284 284  
285 -(% border="1" cellspacing="190" style="background-color:#ffffcc; color:green; width:510px" %)
286 -|=(% style="width: 125px;" %)(((
288 +(% border="1" style="background-color:#ffffcc; color:green; width:510px" %)
289 +|=(% style="width: 121px;" %)(((
287 287  (((
288 288  **AT Commands**
289 289  )))
... ... @@ -291,20 +291,20 @@
291 291  (((
292 292  **Description**
293 293  )))
294 -)))|=(% style="width: 255px;" %)(((
297 +)))|=(% style="width: 200px;" %)(((
295 295  (((
296 296  **Example**
297 297  )))
298 298  )))
299 -|(% style="width:125px" %)(((
302 +|(% style="width:200px" %)(((
300 300  (((
301 301  AT+BAUDR
302 302  )))
303 -)))|(% style="width:110px" %)(((
306 +)))|(% style="width:303px" %)(((
304 304  (((
305 305  Set the baud rate (for RS485 connection). Default Value is: 9600.
306 306  )))
307 -)))|(% style="width:255px" %)(((
310 +)))|(% style="width:340px" %)(((
308 308  (((
309 309  (((
310 310  AT+BAUDR=9600
... ... @@ -317,11 +317,11 @@
317 317  )))
318 318  )))
319 319  )))
320 -|(% style="width:125px" %)(((
323 +|(% style="width:121px" %)(((
321 321  (((
322 322  AT+PARITY
323 323  )))
324 -)))|(% style="width:110px" %)(((
327 +)))|(% style="width:303px" %)(((
325 325  (((
326 326  (((
327 327  Set UART parity (for RS485 connection)
... ... @@ -333,7 +333,7 @@
333 333  Default Value is: no parity.
334 334  )))
335 335  )))
336 -)))|(% style="width:255px" %)(((
339 +)))|(% style="width:340px" %)(((
337 337  (((
338 338  (((
339 339  AT+PARITY=0
... ... @@ -346,11 +346,11 @@
346 346  )))
347 347  )))
348 348  )))
349 -|(% style="width:125px" %)(((
352 +|(% style="width:121px" %)(((
350 350  (((
351 351  AT+STOPBIT
352 352  )))
353 -)))|(% style="width:110px" %)(((
356 +)))|(% style="width:303px" %)(((
354 354  (((
355 355  (((
356 356  Set serial stopbit (for RS485 connection)
... ... @@ -362,7 +362,7 @@
362 362  Default Value is: 1bit.
363 363  )))
364 364  )))
365 -)))|(% style="width:255px" %)(((
368 +)))|(% style="width:340px" %)(((
366 366  (((
367 367  (((
368 368  AT+STOPBIT=0 for 1bit
... ... @@ -382,6 +382,8 @@
382 382  )))
383 383  )))
384 384  
388 +
389 +
385 385  === 3.3.2 Configure sensors ===
386 386  
387 387  (((
... ... @@ -809,6 +809,7 @@
809 809  
810 810  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for RS485-BL.  User can see these commands below:
811 811  
817 +
812 812  === 3.5.1 Common Commands: ===
813 813  
814 814  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.3, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -1168,6 +1168,7 @@
1168 1168  |=(% style="width: 89px;" %)**Button**|=(% style="width: 141px;" %)**Feature**
1169 1169  |(% style="width:89px" %)**RST**|(% style="width:141px" %)Reboot RS485-BL
1170 1170  
1177 +
1171 1171  == 3.7 +3V3 Output ==
1172 1172  
1173 1173  RS485-BL has a Controllable +3V3 output, user can use this output to power external sensor.
... ... @@ -1208,6 +1208,7 @@
1208 1208  |=**LEDs**|=(% style="width: 274px;" %)**Feature**
1209 1209  |**LED1**|(% style="width:274px" %)Blink when device transmit a packet.
1210 1210  
1218 +
1211 1211  == 3.10 Switch Jumper ==
1212 1212  
1213 1213  (% border="1" style="background-color:#ffffcc; color:green; width:515px" %)
... ... @@ -1395,6 +1395,8 @@
1395 1395  * (% style="color:blue" %)**RU864**(%%): frequency bands RU864
1396 1396  * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865
1397 1397  
1406 +
1407 +
1398 1398  = 9. Packing Info =
1399 1399  
1400 1400  (((