Changes for page RS485-BL – Waterproof RS485 to LoRaWAN Converter
Last modified by Xiaoling on 2025/04/23 15:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -282,29 +282,29 @@ 282 282 RS485-BL default UART settings is **9600, no parity, stop bit 1**. If the sensor has a different settings, user can change the RS485-BL setting to match. 283 283 ))) 284 284 285 -(% border="1" style="background-color:#ffffcc; color:green; width:510px" %) 286 -|=(% style="width: 12 1px;" %)(((285 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 286 +|=(% style="width: 120px;" %)((( 287 287 ((( 288 288 **AT Commands** 289 289 ))) 290 -)))|=(% style="width: 1 14px;" %)(((290 +)))|=(% style="width: 190px;" %)((( 291 291 ((( 292 292 **Description** 293 293 ))) 294 -)))|=(% style="width: 226px;" %)(((294 +)))|=(% style="width: 190px;" %)((( 295 295 ((( 296 296 **Example** 297 297 ))) 298 298 ))) 299 -|(% style="width:12 1px" %)(((299 +|(% style="width:120px" %)((( 300 300 ((( 301 301 AT+BAUDR 302 302 ))) 303 -)))|(% style="width:1 14px" %)(((303 +)))|(% style="width:190px" %)((( 304 304 ((( 305 305 Set the baud rate (for RS485 connection). Default Value is: 9600. 306 306 ))) 307 -)))|(% style="width: 226px" %)(((307 +)))|(% style="width:190px" %)((( 308 308 ((( 309 309 ((( 310 310 AT+BAUDR=9600 ... ... @@ -317,11 +317,11 @@ 317 317 ))) 318 318 ))) 319 319 ))) 320 -|(% style="width:12 1px" %)(((320 +|(% style="width:120px" %)((( 321 321 ((( 322 322 AT+PARITY 323 323 ))) 324 -)))|(% style="width:1 14px" %)(((324 +)))|(% style="width:190px" %)((( 325 325 ((( 326 326 ((( 327 327 Set UART parity (for RS485 connection) ... ... @@ -333,7 +333,7 @@ 333 333 Default Value is: no parity. 334 334 ))) 335 335 ))) 336 -)))|(% style="width: 226px" %)(((336 +)))|(% style="width:190px" %)((( 337 337 ((( 338 338 ((( 339 339 AT+PARITY=0 ... ... @@ -346,11 +346,11 @@ 346 346 ))) 347 347 ))) 348 348 ))) 349 -|(% style="width:12 1px" %)(((349 +|(% style="width:120px" %)((( 350 350 ((( 351 351 AT+STOPBIT 352 352 ))) 353 -)))|(% style="width:1 14px" %)(((353 +)))|(% style="width:190px" %)((( 354 354 ((( 355 355 ((( 356 356 Set serial stopbit (for RS485 connection) ... ... @@ -362,7 +362,7 @@ 362 362 Default Value is: 1bit. 363 363 ))) 364 364 ))) 365 -)))|(% style="width: 226px" %)(((365 +)))|(% style="width:190px" %)((( 366 366 ((( 367 367 ((( 368 368 AT+STOPBIT=0 for 1bit ... ... @@ -393,15 +393,15 @@ 393 393 When user issue an (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) command, Each (% style="color:#4f81bd" %)**AT+CFGDEV**(%%) equals to send a command to the RS485 or TTL sensors. This command will only run when user input it and won’t run during each sampling. 394 394 ))) 395 395 396 -(% border="1" style="background-color:#ffffcc; color:green; width: 806px" %)397 -|**AT Commands**|(% style="width: 418px" %)**Description**|(% style="width:256px" %)**Example**398 -|AT+CFGDEV|(% style="width: 418px" %)(((396 +(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %) 397 +|=**AT Commands**|=(% style="width: 110px;" %)**Description**|=(% style="width: 190px;" %)**Example** 398 +|AT+CFGDEV|(% style="width:190px" %)((( 399 399 This command is used to configure the RS485/TTL devices; they won’t be used during sampling. 400 400 401 401 AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx, 402 402 403 403 mm: 0: no CRC, 1: add CRC-16/MODBUS in the end of this command 404 -)))|(% style="width: 256px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m404 +)))|(% style="width:190px" %)AT+CFGDEV=xx xx xx xx xx xx xx xx xx xx xx xx,m 405 405 406 406 Detail of AT+CFGDEV command see [[AT+CFGDEV detail>>||anchor="HRS485DebugCommand28AT2BCFGDEV29"]]. 407 407 ... ... @@ -1396,7 +1396,6 @@ 1396 1396 * (% style="color:blue" %)**RU864**(%%): frequency bands RU864 1397 1397 * (% style="color:blue" %)**KZ865**(%%): frequency bands KZ865 1398 1398 1399 - 1400 1400 = 9. Packing Info = 1401 1401 1402 1402 (((